GSS20DBPJCC General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- ronald from palmyra, VA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
freezer freezing and fresh food compartment not cooling
i unplugged the fridge, first i removed the racks, then unhooked the grounding clip. the i tool off two 1/4 nut screws holding the backplate. then i used my wifes hair dryer to thaw out the ice. after it thawed out i unscrewed the element bracket which is secured by two philips screw. after taking the screws off, its just unplug one end at a time and plug it to the new one to avoid confusion. then reverse install to put back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Schenectady, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
No Defrost - Top of freezer thawing
By the time this failure (failed defroster heating element) is evident (top of freezer starts thawing), the entire freezer coil is encased in a block of ice & frost is visble on the back freezer panel.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GARY from SPRAGGS, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ran All The Time Did Not Freeze.
Removed cover in freezer over evaporator,unbolted element ,plugged ,and replaced, very simple. Should be first thing checked when theres a problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Longs, SC
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer building up Ice
This is such an easy fix!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Sarasota, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Open defrost heater
The most difficult part of the repair was the melting of the ice and preparation. I did change a single element heater for a dual element heater, which required a little manual flexing of the sub-frame, but it assembled with little issue. I was lucky, I did not have to splice the extended harness connection. Rerouting my existing gave sufficent length.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- carol from Du Bois, IL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Defroster quit working. The freezer would frost up and not cool the fridge or freezer properly.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires.Threw away the old defroster. Put the new one in. I had to reroute the blue wire over to the right hand side and plugged it in.Put the back on. put the shelves in and I was done! We had this done just about 3 years ago and it cost us about $175. The cost of this repair was only $38.05 with shipping and all! What a great deal! Thanks so much PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Orient, OH
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frig AND freezer side not cooling
This is a repair INSIDE the freezer. Turned off unit.. Unplugged. Removed shelving on freezer side. Removed freezer draw rails (4 screws total.) Removed 2 screws that hold rear panel in place at rear of freezer side (this is inside the freezer). Carefully removed metal panel by pulling from the left (side that does not have shelving clips. As noted on this website and other users, the freezer coils were incased in ice. Thawed with a hair dryer (put towels in bottom of freezer-ice was pretty heavy in mine). When thawed, remove heater element by removing 2 screws that hold it to the aluminum bracket. Then remove wires on each end. Simply install the new emelment by attaching wires back on heater and screw new unit in place. (My original heating element was a single element-you could very easily see where the heating coil inside the glass tube had shorted out. My replacement heater was a 2 element unit. This did not pose any problem at all-installs in the same manner-good directions are provided.). Replace all parts in reverse order. It's that simple. Saved probably $150. This site is wonderful! Fast shipping and the users install tips/notes are fantastic!! Will shop here again if I have to (have a Maytag washer that isn't draining and going into spin-bet the fix is on here somewhere!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alex from Madisonville, KY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Refrigerator stopped cooling, back panel freezing, not defrosting
The repair itself is super easy. The heater harness comes with instructions that is easy to follow. The only issue I encountered is that my refrigerator had 1 heating element and you will get one with 2 heating elements. Because of this, the new connectors are on 1 side. Since my old heater had 1 connector on each end, 1 wire is too short if you route both wires the same way as before. The kit comes with an extra wire and directs you to splice the short wire and attach the extra wire with the included connector. I figured a refrigerator with a spliced wire is not a good combination so I rerouted the short wire to the other side along with the other wire. This allowed me to connect both wires without using the extra wire.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Melvin from Linesville, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator side of refrigerator/freezer wouldn't stay cool. Ice jam in cooling cools (due to burned out defrost heater) prevented proper air flow.
Removed shelves and light bulb cover. Then removed the two screws that hold the back wall of freezer compartment in place and removed cover. Thawed ice jam with hair dryer. Removed the two screws holding heating element in place and pulled element out far enough to disconnect the two wires. Reconnected wires to new element and put everything back together.
Installation instructions which came with new part were accurate and very easy to understand.
It took about 30 minutes total.
Installation instructions which came with new part were accurate and very easy to understand.
It took about 30 minutes total.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- LaNeisha from Kerrville, TX
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Burned out Freezer defroster element
I had done this repair almost exactly 2 years ago. I also read in this forum about a guy who said he had to do it every 2 years... bad part design.
However, GE has replaced the original single element with a dual element, and that is what PartSelect sent me. I had to splice one wire, but the instructions were clear and it went like a breeze. Oh, and the part arrived less than 3 days after I ordered it with standard shipping. Way to go, guys! Thanks!
However, GE has replaced the original single element with a dual element, and that is what PartSelect sent me. I had to splice one wire, but the instructions were clear and it went like a breeze. Oh, and the part arrived less than 3 days after I ordered it with standard shipping. Way to go, guys! Thanks!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from El Dorado, AR
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Bottom of refrigerator wouldn't coool
I removed the top vent and unplugged the ice machine ,took the back cover off the freezer.Removed the old fan which was pretty easy(unplugged it after I took the housing out for easy access) I plugged the new fan in and put everything back in the order I took off, and yada yada yada we have cooling.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from Deerfield Beach, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Coils at back of freezer icing over
After reading posts on this website, I determined I needed to replace the defrost heater. Removed heater to take a closer look and after testing with a voltmeter determined it needed replacing. Ordered part online and could not believe how quickly it arrived. Blue wire that travels down the left side of the freezer coils had some damage on the end of the plastic connector so was pleased to find that I was able to splice the extension wire provided in the defrost heater kit onto the blue wire and dispose of the damaged end. It's been about 10 days and I do believe my problem has been solved!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- frank from Pittston, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Appeared to be too large at first...
At first the part appeared to be too large because of the change from one heater to two heaters in the replacement part. It was necessary to push a copper refrigerant line back out ot the way about an inch or so before the part would fit properly. This might take a little courage from the do-it-yourselfer, but it moved easily and seems no worse for the move. Currently the fridge is working well(two weeks) with no buildup of any frost on freezer panel as previouly noted. Overall experience was just fine. Makes d-i-y guy look good!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jose from Castaic, CA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Frost buildup on the inside back wall of freezer, refrigerator section not cooling
Removed shelves and storage drawer from freezer.
Removed the two screws that mount the rear panel cover at the back of the freezer
compartment. Disconnected the grounding clip on the cover exposing the evaporator coils and the defrosting heater at the bottom.
Removed the remaining ice chunks on the coils.
Removed the two screws mounting the single element defroster. Disconnected the wires on each end of the defroster.
The replacement defroster was a two element heater and the instructions clearly showed how to re-route the single wire from the left side to the right side. The harness kit included a short piece of wire and a crimp connector to ensure the length would be sufficient to connect the new heater.
The only item missing in the kit was the RTV required to water proof the wire connection. A quick run to the hardware store took care of that.
Reassembled in reverse order, plugged the refrigerator back in and by the next day temperatures were normal in both the freezer and refrigerator compartment.
A service repairman had quoted $60.00 for the defrost heater plus $250.00 for installation. Using parts from PartSelect the total cost was $44.00 including shipping and about 30 minutes of my time. I'll take the savings anyday.
Thanks for the easy to read instructions and multiple status email notes of the order.
Removed the two screws that mount the rear panel cover at the back of the freezer
compartment. Disconnected the grounding clip on the cover exposing the evaporator coils and the defrosting heater at the bottom.
Removed the remaining ice chunks on the coils.
Removed the two screws mounting the single element defroster. Disconnected the wires on each end of the defroster.
The replacement defroster was a two element heater and the instructions clearly showed how to re-route the single wire from the left side to the right side. The harness kit included a short piece of wire and a crimp connector to ensure the length would be sufficient to connect the new heater.
The only item missing in the kit was the RTV required to water proof the wire connection. A quick run to the hardware store took care of that.
Reassembled in reverse order, plugged the refrigerator back in and by the next day temperatures were normal in both the freezer and refrigerator compartment.
A service repairman had quoted $60.00 for the defrost heater plus $250.00 for installation. Using parts from PartSelect the total cost was $44.00 including shipping and about 30 minutes of my time. I'll take the savings anyday.
Thanks for the easy to read instructions and multiple status email notes of the order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- C J from PARKER, AZ
- Parts Used:
- WR51X10101
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freezer frosted over and Rrigerator side would not maintain temperature due to failure of defrost heater
After viewing on Youtube I knew exactly what to expect in the repair process. It was easy, easy and saved me a 90 dollar service call plus an over priced replaement part. Time to repair was 25 minutes and included my kid taking the screwdriver.
Was this instruction helpful to you?
Thank you for voting!