MTRC0FAZARWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- James from Bel Air, MD
- Parts Used:
- WR55X24064
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Refrigerator and freezer drawer would not maintain set temperature
Condenser fan motor was running slow. This was not a problem included in your list of possible problems. I thought that maybe the capacitor was bad but have no way to check it. So I ordered one. when I received it, I installed it. That was not the problem. So I ordered a fan motor and installed it. That was not the problem. So finally I ordered a control board and installed it. That solved the problem. So maybe you should put "cond.fan motor runs slow" in your list of possible faults and what causes that problem. Capacitor was easy to install, simply remove the cover plate, flip off retaining wire, unplug the capacitor and replace. Fan motor was a bit more difficult. It must be removed from mount after fan scroll is removed. Remove one screw that holds scroll, bend the top down and remove. Then pull hard on fan blade to remove it. It must be installed on new motor. Two screws in frame mount can be removed with some effort if you have a 1/4" drive ratchet with a Phillips screwdriver bit. Then pull frame open and install new motor. Push fan blade on new motor shaft hard. Replacing control board was easy. I used a pair of long nose pliers with 90 degree bend to get mounting pins closed to pull board off.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Andenet from Haymarket, VA
- Parts Used:
- WR60X10220
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Fan and housing cannot be removed together.
On partselects video the gentleman removes the fan and housing in one piece. This is a great idea but does not work on this brand of ge. I removed the fan housing screw as instructed but left it in place and swiveled it enough to access the retaining screws with a socket driver. Over all swap of the fan was seamless and the video is a gem. Andy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from York, PA
- Parts Used:
- WR60X10220, WR60X10207
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer not cold, Frig cold enough, runs all the time, Hot to touch in spots.
My compressor fan that blows over the coils was not spinning. I measured 120 VAC going to the fan so I knew it should have been spinning but wasn't. Took fan motor out and took it apart and super lubed the motor to get it spinning again temporarily until I could get the new one in. Put new one in and has been working for about 10 days now. Freezer is not below 0 deg F which is what you want. Frig is below 40 deg F also what you want.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- rodney from cave city, AR
- Parts Used:
- WR60X10220, WR60X10207
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Socket set
warm in lower area and not freezing good in freezer area
condenser fan on bottom condenser not runningchanged fan and fan motor
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from Seattle, WA
- Parts Used:
- WR60X30922
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
broken fan blade
about an hour to figure out what was causing the vibration and noise and about an hour to put it back together and 5 min. to order a new fan blade thank you.It started making noise during thanksgiving dinner so we toke it apart after dinner and I cut the other 2 blade to match the broken one so to cut down on the noise and vibration semi put it back together and 7 days later the part arrived.
Was this instruction helpful to you?
Thank you for voting!