- Customer:
- Paulette B. from Santa Ana, CA
- Parts Used:
- WR2X9391
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
Light in the refrigerator went out
After I bought what I thought I needed for the repair. I asked a friend to come over and look at it. He changed the
the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.
Getting on the internet was so easy. This was really very simple. Thank you for making what I thought would be a big ordeal into something very simple.
Paulette Johnson
the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.
Getting on the internet was so easy. This was really very simple. Thank you for making what I thought would be a big ordeal into something very simple.
Paulette Johnson
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Glen from Harrisburg, OR
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
This part on refrigerator went out, wouldn't dispense water.
I removed the back cover on the refrigerator. Unbolted the unit. First of all I unpluged the refrigerator. Took off the two electrical connections and removed the input and output water lines. I then reversed this process when I installed the new part. It was real easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Timothy from West Windsor, NJ
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers, Wrench set
Replace Dual Inlet Water Valve
Unplug the electrical power to the refridgerator, remove old valve, marking which electrical wire set goes to which solenoid valve. Cut the nut fasteners from the ice maker and front door water tubes. Leave the nut fastener on the supply line.
New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.
New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from Columbus, IN
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers, Wrench set
water valve leak
This Valve Has 2 Different Size Water Lines Going In To It And They Are Different Diameters.Each Has Its Own Collar That Locks The Lines Into It. Make Sure That You Put The Right Size Collar Over The Line Before You Insert It Into The Valve, Because Once You Put The Line In You Cant Pull It Back Out Without Messing Up The Valve. Make Sure It Is Right Because You Only Get One Shot At It.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jimmy from Palmer, TN
- Parts Used:
- WR50X122
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Defrost Thermostat quit working
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Laura from Manchester, NH
- Parts Used:
- WR02X11330
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marion from Palm Coast, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refridgerator Freezer stoped making ice
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Silicone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JEFF from HAMPTON, GA
- Parts Used:
- WR60X187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
Was this instruction helpful to you?
Thank you for voting!
Refrigerator door wouldn't close automatically.
Removed the top hinge with a socket and lifted the door off. Removed the bottom hinge from the refrigerator with same sized socket. Used a Dermel to cut out the old rivet holding the old mangled cam. Attached the new cam with a screw, washers and nut. Reattached bottom hinge to the refrigerator. Removed the bracket holding the second cam on the bottom of the door. Replaced the shim and cam. Reinstalled the door. No problems. Just don't make the same mistake I made. You need two cams. They interlock and work together to close the door automatically. The cams are identical. They are just off set by 90 degrees when the door is closed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from Magnolia, TX
- Parts Used:
- WR51X442
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
The refrigerator section of my side by side was not getting as cold as it should have been.
It was easy after finding PartSelect online. It wasn't obvious at first that my evaporator core(in back of freezer side) was frosting over, (since I have a flat white panel that is about 8 x 30 inches covering it), until I reached inside and ran my fingers over the cover and noticed a thin layer of frost on it. At this point I told my buddies to go get ice for our beer cuz I was fixin to do a lock out/tag out on the Fridge. Seriously, Do disconnect the electrical power before taking it apart. After taking the 9 screws (6-1/4" hex heads & 3-#2 phillips)out and removing the panel, I saw that the evaporator core was completely frosted over. I then put a large towel in the bottom and let it thaw for a day. Next day after getting the old Defrost Heater Kit with Thermostat out (4-#2 phillips, plug-in electrical connection, thermostat snap on clip) , I noticed it was burnt inside the filaments and did not pass the continuity test. I then ordered my part from PartSelect and took the oppurtunity to clean my fridge spotless. 3 business days later, I received my part, installed it, and now have a "like new" refrigertor. Actual repair time - 30 minutes, Overall down time - 4 days, Saving the cost of a new Fridge - a heck of lot more beer!
Was this instruction helpful to you?
Thank you for voting!
The auger was chromed steel. It rusted causing rust to get on ice.
It's a good idea to take closeup pictures, that will eliminate guessing when you put it back together. There was no instructions. I was happy to see GE knew there was a problem with the chrome auger. The replacement is STAINLESS STEEL.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- TIM from GRETNA, LA
- Parts Used:
- WR2X4550
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Maker Cap Broke
It took me about 15 minutes to complete the repair, 1st I emptied the ice maker, then I removed 4 screws from the rear of the ice maker tray and took the plastic piece off of the auger. I reversed the steps and put it back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Auburn, AL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Greg from Vicksburg, MS
- Parts Used:
- WR51X442
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ref/frig not cooling
Removed the 4 screws holding the back panel in freezer compartment and then removed panel. Removed the 4 screws holding defrost heater and removed it. The replacement parts fit perfect , plug the new part in and bingo my frig is operating like a new one. Took about 15 minutes to make the repair. Took longer to defrost the ice buildup on the coils ( 1hr ) than to do the repair (15 min). I can't believe i would have been paying an appliance repairman to hold a hair dryer for an hour. Your diagrams showing where the various parts are located on the appliance are invaluable. Would recommend PartsSelect to anyone and I am sure that I will be ordering parts for my other appliances as needed. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Somers Point, NJ
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.
10 minutes total.
10 minutes total.
Was this instruction helpful to you?
Thank you for voting!