Models > TPX24B1YABB > Instructions

TPX24B1YABB General Electric Refrigerator - Instructions

Jump to:

All Instructions for the TPX24B1YABB
16 - 30 of 562
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
John from Lodi, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
33 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MARYT from KISSIMMEE, FL
Parts Used:
WR72X242, WR72X240
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
the cheap plastic drawer holders broke!
Not only were the parts delivered in 2 days....but a phillips head screw driver and matching up the new rails with the old ones turned out to be a super easy and fast repair!! A monkey could do this repair!! But now I noticed the left hand top drawer rail is cracked! It stinks that the quality of the original parts are so poor...but at least I'm saving some money doing it myself!!!
31 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alok from Alpharetta, GA
Parts Used:
WR51X443
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer wasn't keeping food frozen
First I turned the freezer off and took out all of the shelves in the freezer section. I then removed the guides that the shelves go into. I removed these only from one side of the freezer - the left side actually. Now I removed the plastic piece that keeps the bulb in the freezer protected. Removed the bulb. Removed the three screws on the top and the two in the bottom that keep the rear panel of the freezer attached. This exposed the header cable and the coils. The coils had ice on the lower section, I used a hair dryer to melt the ice. Removed the cable assembly that has the two heater elements and the thermostat. The thermostat had to be plucked off the the metal pipe of coils. Replaced the assembly with the purchased assembly. Clipped the thermostat onto the metal pipe of the coils. COnnected the wires at the white connector. Attached the real panel using the five screws, put the bulb back in, installed the bulb cover, installed the shelf guides, put the shelves back in.

Freezer freezes very well now.
24 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GARY from PARRISH, FL
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Wrench set
Failed Icemaker
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
35 of 62 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brian from Tallulah, LA
Parts Used:
WR9X489, WR51X443
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set
Freezer would ice up and refrigerator stop cooling
First i unpluged the power then cleaned everything out of freezer and removed all the drawers and racks them removed the 2 screws at bottem of freezerand removed panel then removed 4 screws on the bulbs and unpluged the wire and took off the sensor and replaced with new one put everthing back. Then on the top of refigerator side on the top behind the adjuster is the defrost timer pulled handle out and off removed plastic shield and removed 2 screws and unplug the timer and change it then put everything back and pluged back in and everything worked in a few minutes
22 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Theresa from Rochester, MI
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Wrench (Adjustable)
low flowing water (not just a drip) from refrigerator ice maker
The icemaker's valve is easy to inspect and test. First, gently pull the refrigerator away from the wall, and unplug it. Turn off the water supply to the icemaker by closing the shut-off valve in the copper waterline leading to the valve. Use a screwdriver or nutdriver to remove the rear lower access panel from the refrigerator's back.

Next, remove the fill tubing from the water valve. Use a wrench to loosen the flare nut on the brass fitting on the inlet side of the valve (above). Place a container or towel under the valve to catch the small amount of water that will spill from the valve and tubing.

Now use a screwdriver or a nutdriver to remove the screw holding the valve's mounting bracket to the refrigerator cabinet. Pull the valve out of the compartment and remove the tube (or tubes if both water dispenser & ice maker) on the valve's outlet. If plastic tubes don't come out with pliers and assuming there is enough extra tubing, then cut the plastic tubing with a even straight cut edge razor. Then, remove the solenoid's electrical contacts.

Push the plastic water and ice tubes int he appropriate holes in the new valve outlet, reconnect solenoids and remount new water valve.

Before installing the back panel on the refrigerator cabinet, test run the icemaker. Look for leaks, and tighten any leaky connections. If necessary, use Teflon tape or a similar product to ensure tight connections. Discard the first ice cubes that are produced because they are likely to have sediment in them.
23 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Charlotte, NC
Parts Used:
WR72X240, WR72X239
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Both Slides Were Broken
I removed the shelf, unscrewed the slide rails and replaced them with new ones. I replaced the shelf, put the food back in and I was done. Thanks, john bowers
23 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Glendale, AZ
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
21 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Mebane, NC
Parts Used:
WR29X5171
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Ice maker would not make ice..
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmmeter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
19 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rene from Bronx, NY
Parts Used:
WR9X489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Frig would stop working every so often. Lots of food got spoiled.
Got part overnight. Unscrewed cover plate at top of regerator compartment, disconnected old part, connected new part. Screwed back plate. Voila!

I saved a bunch of money!
17 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tracy from Yuba City, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from Madison Heights, MI
Parts Used:
WR9X489
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Refrigerator to warm freezer ok
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
16 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David T from Irvine, CA
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
Water Leak From The Ice Make - Water All Over The Frig
Replace the old water valve (wr57x11) with the new one (wr57x10051: make sure you unplug the 110 ac power . And close the water come to the refrig. First 1. Open the paper panel on the back with screw driver. 2 Use a small adj. Wrench to take the old valve of. 3. Label the connector and its terminals in a proper number to identify their connector. 4. Unscrew 2 water hoses - one to the drinking one to the ice maker. They are in diff. Sizes - make sure to mark where the hoses connected in case you need to use it again. 5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve. 6. Make sure the new valve is in the same position as the old one. Then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve. 7. Secure the valve onto the refig frame then plug in the water hose to make sure no leak at the valve. The new valve has new type of self-lock plug ( not thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water . Valves. Turn on the water and power on on the refrig. That's all. Very simple save $300 for hiring the service man. Good luck to all.
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cristina from Los Angeles, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carlton from Chino, CA
Parts Used:
WR72X239
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
the left drawer slide rail was broken from years of use.
First I removed the vegetable drawer and glass shelf. I matched up the 'new' drawer slide rail next to the broken slide.
I then used a phillips head screwdriver to remove the 2 screws that held the slide in place.
After removing the broken slide rail, I installed the new rail, replaced the vegetable drawer and glass shelf. New item worked like a charm.
The drawer slide arrived really quick after my order was placed. Approx. 2 days after ordering the part, it was on my front door step.
16 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TPX24B1YABB
16 - 30 of 562