GSR23YBTASS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Rene from HEBER, CA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
condenser icing refrigerator warm freezer ok
follow the easy instructions replace 3 temperature sensors cut the wires and crimp them with new sensor and it works like new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from West Winfield, NY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
The fridge was making a clicking sound, and not cooling the food
The back panel was unscrewed, we read the directions with the circuit board and followed them. It was very easy to unplug the old faulty unit and plug in the new replacement part. It was done in 4 minutes flat. Very easy to do yourselves!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Enrique from east stroudsburg, PA
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Therefrigerator side was not cooling
I removed the cover on the back of the freezer side of refrigerator to expose the anti freeze element use the hair blow dryer to melt the ice on the coils put 2 towels to colect the water thats wath take me time, to replace the heath element was a 1 minute job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sonya from Sugar Land, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
no water from dispenser, then constant clicking sound, and frig went warm
After reading this forum and other searches, I assumed replacing the board may solve my problem. Unscrewed the back plate, used pliers to pull out the connectors, squeezed in the sides of the 4 plastic white board holders to release the board, and then replaced old board with the new one and reconnected connectors. (My model was not one of the mentioned models for cutting the 2nd pin of the J1 connector, so I left it in.) Upon plugging my frig back in, it began working perfectly again. So thankful to have found this forum!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Chicago, IL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Temp panel flashed "hrs", refrigerator would not work
Remove back panel to expose the control board. Simply unplug cables from old board and pull the board out, no tools required. Put new board in place and replace the cables. Very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Judy from KILLEN, AL
- Parts Used:
- WR71X10761
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
tray broken
slide in place
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carl from BELLVILLE, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Unit was dead
Removed and replaced control board
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- KENSIL J from JACKSONVILLE, NC
- Parts Used:
- WR49X10091
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
water dispen.kept freezing up
remove light cover then remove 4 screws holding light fixture in place pulled out fresh food inlet cover and had to removed 2 more screws at bottom of cover then unplug electrical connector. replace with new one then replace all 6 screws and light cover done. so far its been working great no more freeze ups.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Trudy from Saint Cloud, FL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator would not get cold
UNPLUG! (Read Instructions for wiring configuration) Remove cover lower back right hand side.Remove ribbon plugs top and bottom you will need to lever back holding tab while pulling plug they will more than likely break dont worry you are throwing this part away., disconnect ground wire, compress plastic holding tabs,
pull off control board, plug in new board push on to holding tabs reconnect ground and turn on refrigerator and check replace cover, everything is now working great.
pull off control board, plug in new board push on to holding tabs reconnect ground and turn on refrigerator and check replace cover, everything is now working great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harry from DURYEA, PA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wanda from HENDERSON, NV
- Parts Used:
- WR71X10761
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
Plastic shelf inserts in refrigerator were cracked
Manually inserted new refrigerator module inserts
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bryan from LANDING, NJ
- Parts Used:
- WR24X20455
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
Freezer Gasket was torn in some spots, freezer had condensation inside and could not maintain zero degree temperature.
Ordered gasket. Laid out gasket near sunlit window untangled and flat on carpet for 24 hours to insure it was pilable and correct shape. Removed the old gasket manually easily without any tools and cleaned the door's seal groove with a paper towel slightly soaked with Simply Green. Installed new gasket starting at the upper corners then inserting upper edge by tilting the gasket toward the inside of the door with my fingers. Then installed the lower corners along with the bottom edge. Proceeded installing the side edge working from the set corners inserting the gasket's inner tongue into the door groove with my fingers again tilting the gasket inside the door. Once the gasket was installed, I closed the door and guided my fingers along the gasket to insure the magnetic edge formed a firm seal. This is wear the DIY videos suggested applying petroleum jelly but I did not need it since the gasket was pliable enough. Overall, the effort took 15 minutes because I think laying out the gasket for 24 hours allowed it to settle into its desired form..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Crista from Canal Winchester, OH
- Parts Used:
- WR24X20455
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
Our freezer door wasn’t sealing properly
It was so much easier than I thought. First we used a hair dryer to loosen everything up. Just pulled off the old on (with our hands) and put the new one on. Then went around the edges and wiggled it into place. There are plastic ridges that if fits into, so it’s important to make sure every part is sealed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jaime from SYLMAR, CA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
No Cooling on either freezer or refrigerator
Everything seemed to be working right, but no cooling, so I tried turning on and off the switch that turns the light on 5 times within two seconds, refrigerator did not shot. so I removed the main board and I notice a short had taken place on one of the relay legs. I ordered the main board and replaced it. The main board is on the back of the freezer covered with a sheet metal panel about 8"x8" and is secured with hex sheet metal screws. Everything is working now. Please make sure to unplug the unit from power before removing the main board.
Was this instruction helpful to you?
Thank you for voting!