Customer:
Patrick from Medford, NY
Parts Used:
WR9X489
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge wouldn't start
Removed cowling unpluged timer and pluged in new one.
Great Service, got part in one day
12 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Virginia Beach, VA
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper was stuck open. Old and warped.
Replaced flapper
16 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paulette B. from Santa Ana, CA
Parts Used:
WR2X9391
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Light in the refrigerator went out
After I bought what I thought I needed for the repair. I asked a friend to come over and look at it. He changed the
the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.

Getting on the internet was so easy. This was really very simple. Thank you for making what I thought would be a big ordeal into something very simple.

Paulette Johnson
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from Columbus, IN
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers, Wrench set
water valve leak
This Valve Has 2 Different Size Water Lines Going In To It And They Are Different Diameters.Each Has Its Own Collar That Locks The Lines Into It. Make Sure That You Put The Right Size Collar Over The Line Before You Insert It Into The Valve, Because Once You Put The Line In You Cant Pull It Back Out Without Messing Up The Valve. Make Sure It Is Right Because You Only Get One Shot At It.
10 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jimmy from Palmer, TN
Parts Used:
WR50X122
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Defrost Thermostat quit working
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leo from TWIN FALLS, ID
Parts Used:
40A15
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
22 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laura from Manchester, NH
Parts Used:
WR02X11330
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
16 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wayne from Magnolia, TX
Parts Used:
WR51X442
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
The refrigerator section of my side by side was not getting as cold as it should have been.
It was easy after finding PartSelect online. It wasn't obvious at first that my evaporator core(in back of freezer side) was frosting over, (since I have a flat white panel that is about 8 x 30 inches covering it), until I reached inside and ran my fingers over the cover and noticed a thin layer of frost on it. At this point I told my buddies to go get ice for our beer cuz I was fixin to do a lock out/tag out on the Fridge. Seriously, Do disconnect the electrical power before taking it apart. After taking the 9 screws (6-1/4" hex heads & 3-#2 phillips)out and removing the panel, I saw that the evaporator core was completely frosted over. I then put a large towel in the bottom and let it thaw for a day. Next day after getting the old Defrost Heater Kit with Thermostat out (4-#2 phillips, plug-in electrical connection, thermostat snap on clip) , I noticed it was burnt inside the filaments and did not pass the continuity test. I then ordered my part from PartSelect and took the oppurtunity to clean my fridge spotless. 3 business days later, I received my part, installed it, and now have a "like new" refrigertor. Actual repair time - 30 minutes, Overall down time - 4 days, Saving the cost of a new Fridge - a heck of lot more beer!
10 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from N. Merrick, NY
Parts Used:
WR2X7491, WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
Refrigerator door wouldn't close automatically.
Removed the top hinge with a socket and lifted the door off. Removed the bottom hinge from the refrigerator with same sized socket. Used a Dermel to cut out the old rivet holding the old mangled cam. Attached the new cam with a screw, washers and nut. Reattached bottom hinge to the refrigerator. Removed the bracket holding the second cam on the bottom of the door. Replaced the shim and cam. Reinstalled the door. No problems. Just don't make the same mistake I made. You need two cams. They interlock and work together to close the door automatically. The cams are identical. They are just off set by 90 degrees when the door is closed.
10 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marion from Palm Coast, FL
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refridgerator Freezer stoped making ice
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Silicone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
17 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JEFF from HAMPTON, GA
Parts Used:
WR60X187
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Auburn, AL
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
14 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Greg from Vicksburg, MS
Parts Used:
WR51X442
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Ref/frig not cooling
Removed the 4 screws holding the back panel in freezer compartment and then removed panel. Removed the 4 screws holding defrost heater and removed it. The replacement parts fit perfect , plug the new part in and bingo my frig is operating like a new one. Took about 15 minutes to make the repair. Took longer to defrost the ice buildup on the coils ( 1hr ) than to do the repair (15 min). I can't believe i would have been paying an appliance repairman to hold a hair dryer for an hour. Your diagrams showing where the various parts are located on the appliance are invaluable. Would recommend PartsSelect to anyone and I am sure that I will be ordering parts for my other appliances as needed. Thanks
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
TIM from GRETNA, LA
Parts Used:
WR2X4550
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice Maker Cap Broke
It took me about 15 minutes to complete the repair, 1st I emptied the ice maker, then I removed 4 screws from the rear of the ice maker tray and took the plastic piece off of the auger. I reversed the steps and put it back together.
11 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Ashton, MD
Parts Used:
WR2X7905, WR2X4550, WR2X4141, WR2X4140, WR2X4139, WR17X2058
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Pliers, Screw drivers
bucket drive shaft disengaged from motor drive
This is a 25 year old unit. The ice bucket had warped over time causing the face plate to move forward of its ideal position pulling the entire assembly out of the drive. Removed dispensing unit face assembly. Removed drive shaft assembly. Replaced all washers. Reversed old broken drive cup. Married old drive cup to new drive cup...lining up drive slots. Drilled 6 ea. 3mm holes evenly spaced around circumference into the face of the old drive cup. Fastened drive cups together in vice and with C clamp...then using phillips head screws installed 3 ea. from opposing entry points on each side of this homemade shaft extender. This "mechanism" increased the effective length of the dispensing shaft assembly allowing for a proper fit of the drive shaft to the motor drive connection. Unit now works perfectly. Total cost @ $40.00 and two hours work which would have taken less than one hour if I had remembered to install the ice bucket seal the first time. New ice bucket would have cost @ $185.00. Home warranty does not cover ice makers or any of the associated parts. DIY...it isn't that difficult.
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!