38489KBSLRSS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Bradley from Cedarburg, WI
- Parts Used:
- WR60X10207, WR02X12149
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Condensor fan blade cracked, blade was sheared off.
First, remove the cardboard cover on the back, lower portion of the refrigerator.
Next, locate the condensor fan motor assembly and blade. (Right side as you are facing)
Using a pliers, hold the shaft to keep it from turning and prevent damage to the motor. Using a screwdriver, slide the old ring compression on the blade shaft toward the motor (away from the fan blades) to loosen.
Remove old blade from the shaft by firmly grasping the motor shaft with a pliers (to prevent from damaging) and pull the blade assembly off.
Reverse the above steps to attach the new blade.
Next, locate the condensor fan motor assembly and blade. (Right side as you are facing)
Using a pliers, hold the shaft to keep it from turning and prevent damage to the motor. Using a screwdriver, slide the old ring compression on the blade shaft toward the motor (away from the fan blades) to loosen.
Remove old blade from the shaft by firmly grasping the motor shaft with a pliers (to prevent from damaging) and pull the blade assembly off.
Reverse the above steps to attach the new blade.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eileen from Coto de Caza, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
switchlight on my refrigerator was not working
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from BERLIN, MD
- Parts Used:
- WR07X26748
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
refrigerator would not get cold
got on part select web site and found other customers that had same problem and on their site they had comments from them to fix problem. I then took off back panel on frig where compressor is by removing 6 screws and found the relay attached to the compressor then pressing down on holding spring removed 2 wire alligator clips and it was bad ordered one from part select put the new one on an frig was fixed. entire fix took about 30 minutes from isolating problem to fixing it. thank you part select
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from TRAVERSE CITY, MI
- Parts Used:
- WR60X10172
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Loud noise coming from freezer. Evaporater fan was still spinning but making loud noise
Removed fan housing from top of freezer, then the two screws holding the rest of it in place. Then two more screw and removed the vertical housing in back of freezer. two more screws and I was able to remove the whole back plate. I unplugged evap motor wire from back of freezer wall and unscrewed motor bracket. once motor was free, I removed the blade, unscrewed ground wire and installed new motor. I then plugged wire back in to ensure new motor worked and put everything back. Super Easy!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paypal_shipping_address from Ripon, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jodi from Benton Harbor, MI
- Parts Used:
- WR23X37285
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from E. Hartland, CT
- Parts Used:
- WR72X10086
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
broken part
easy - replaced it
i am totally impressed with your company how effective it is.... i will go to yours if anything is broken or replaced
thanks
i am totally impressed with your company how effective it is.... i will go to yours if anything is broken or replaced
thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- MaryLou from Levittown, NY
- Parts Used:
- WR60X10207
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
Noise in the back of freezer
I must thank yo for sending the fan so fast. If I ever have to deal with any appliance again, you are first on my list.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- david from torrington, CT
- Parts Used:
- WR50X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
freezer worked but thelower part where the milk and the fruit are was warm checked on your site to get help and you were on the money with telling me it was the thermostat i orderd it and it solved the problem thank you.
i took the backing off with a screwdriver, cut the wires and put the 2 wires on that came with the thermostat. p.s. make sure you pull the power plug before you start.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from PARKVILLE, MO
- Parts Used:
- WR02X10098
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Had a 'ticking' sound
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side of the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from BRADENTON, FL
- Parts Used:
- WR50X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Evaporator coil freeze up
Up plug from wall removed rear access cover in freezer let thaw out and replace two wire sensor had previously checked out knowing the defrost strip was good and the defrost thermostat was visually deformed and tested open at freezing and 40 degrees
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from Charlotte, NC
- Parts Used:
- WR50X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Freezer was cold but fridge was warm. Coils in the back of the freezer were getting frosted. Defrost Sensor was broken
-Empty the freezer
-Take the cover in the back of the freezer off
-Melt the ice off the coils (heat gun, hot water, etc.)
-Cut the wires off the old sensor and connect the new sensor using a soldering iron or some other method.
-Cover the spliced wire with heat shrink, electrical tape or some other method.
-Reassemble the cover
Done!
-Take the cover in the back of the freezer off
-Melt the ice off the coils (heat gun, hot water, etc.)
-Cut the wires off the old sensor and connect the new sensor using a soldering iron or some other method.
-Cover the spliced wire with heat shrink, electrical tape or some other method.
-Reassemble the cover
Done!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from E LONGMEADOW, MA
- Parts Used:
- WD2X5166
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Socket set, Wrench (Adjustable)
water leaking from under dishwasher
Water was leaking from under the GE dishwasher, but once we pulled it out, had apparently been going on for a little while. Turning the water off to the dishwasher made it stop, so it was happening even when the unit was not running, potentially indicating somewhere early in the path of the water to and into the machine.
Indeed, inspecting the water inlet vale showed a slow leak. Getting the replacement part was fine, and it fit the electrical, water inlet (existing 90-degree water inlet elbow), and water outlet connections just fine - but the original machine screws that held on the original water inlet valve did not work. It took a little research to figure out the new type of screw required, which was apparently a 10/16 Type AB, which seemed to be a less common type of sheet metal screw (with a point), as opposed to the original flat-ended machine screws. So, after ordering those separately (which were a bit expensive), it went together fine.
A note on the water inlet valve part just indicating the the threading on those parts has changed over time, so potentially ordering the screws to attach it might be worthwhile, would be good information to add about the water inlet valve.
Indeed, inspecting the water inlet vale showed a slow leak. Getting the replacement part was fine, and it fit the electrical, water inlet (existing 90-degree water inlet elbow), and water outlet connections just fine - but the original machine screws that held on the original water inlet valve did not work. It took a little research to figure out the new type of screw required, which was apparently a 10/16 Type AB, which seemed to be a less common type of sheet metal screw (with a point), as opposed to the original flat-ended machine screws. So, after ordering those separately (which were a bit expensive), it went together fine.
A note on the water inlet valve part just indicating the the threading on those parts has changed over time, so potentially ordering the screws to attach it might be worthwhile, would be good information to add about the water inlet valve.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brad from SPRING MILLS, PA
- Parts Used:
- WR02X10098
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
Noisy
I didn’t do the repair because I ordered two grommets. When they arrived, one of the packages was empty! Instead of just sending me another one, they refunded the part so I still need one. By the way, I was not refunded half the shipping either which was more than the part itself.
Was this instruction helpful to you?
Thank you for voting!