TFJ22JABGWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- carol from Du Bois, IL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Defroster quit working. The freezer would frost up and not cool the fridge or freezer properly.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires.Threw away the old defroster. Put the new one in. I had to reroute the blue wire over to the right hand side and plugged it in.Put the back on. put the shelves in and I was done! We had this done just about 3 years ago and it cost us about $175. The cost of this repair was only $38.05 with shipping and all! What a great deal! Thanks so much PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Alpharetta, GA
- Parts Used:
- WR13X10020
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
door would not close by itself - broke cam riser
My right door (food door on side-by-side) stopped closing - I found pieces of the plastic washer (cam riser) on the floor. After reading the stories on the web I decided to order the new part - and YES there are many universal parts that work for Kenmore/GE. The part comes with two parts (hinge and cam riser) - you should install both to insure a good fit. I took 3 blocks of wood and a shim and supported the bottom center of the door, unscrewed the hinge off and dropped it out (3 minutes). The "only" tough part was unscrewing the cam riser from the bottom of the door - it required a very small socket and you will only have about 6-8 inches of work space. Be sure you have a socket that fits before you take the hinge off. The entire repair took less than 30 minutes and contrary to some of the posts, you DO NOT need to take the door off. Good as new again!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alex from Madisonville, KY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Refrigerator stopped cooling, back panel freezing, not defrosting
The repair itself is super easy. The heater harness comes with instructions that is easy to follow. The only issue I encountered is that my refrigerator had 1 heating element and you will get one with 2 heating elements. Because of this, the new connectors are on 1 side. Since my old heater had 1 connector on each end, 1 wire is too short if you route both wires the same way as before. The kit comes with an extra wire and directs you to splice the short wire and attach the extra wire with the included connector. I figured a refrigerator with a spliced wire is not a good combination so I rerouted the short wire to the other side along with the other wire. This allowed me to connect both wires without using the extra wire.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daylyn from Houston, TX
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator not cooling // freezer running non-stop
Fortunately while my refirgerator was still under warrant I had this same problem and watched the repairman fix it. To confrm my suspicions I cleaned out the freezer compartment, removed the back panel (2 screws), and used a hair dryer to defrost it. I suggest plugging the drain hole or laying a towel in the bottom of the compartment to catch the run off or your drain pan could over low. Once defrosted I was able to verify that the element on the defrost heater was burnt. Since it was Sunday I re-assembled and cranked it back up until I could get the part. I did a goggle search on Monday, found the part instantly using only the model number from the refrigerator at PartsSelect.com. The part arrived Wednesday as promised, I repeated the process from Sunday, removed the defective part (2 screws & 2 plug in type wire connections) and she works like a charm now. I do think the manufacture of the part should consider a new design since this is the second one my unit has needed in less than 5 years. At only $27.50 ea. I should have purchased a spare to have for the next time!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Orient, OH
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frig AND freezer side not cooling
This is a repair INSIDE the freezer. Turned off unit.. Unplugged. Removed shelving on freezer side. Removed freezer draw rails (4 screws total.) Removed 2 screws that hold rear panel in place at rear of freezer side (this is inside the freezer). Carefully removed metal panel by pulling from the left (side that does not have shelving clips. As noted on this website and other users, the freezer coils were incased in ice. Thawed with a hair dryer (put towels in bottom of freezer-ice was pretty heavy in mine). When thawed, remove heater element by removing 2 screws that hold it to the aluminum bracket. Then remove wires on each end. Simply install the new emelment by attaching wires back on heater and screw new unit in place. (My original heating element was a single element-you could very easily see where the heating coil inside the glass tube had shorted out. My replacement heater was a 2 element unit. This did not pose any problem at all-installs in the same manner-good directions are provided.). Replace all parts in reverse order. It's that simple. Saved probably $150. This site is wonderful! Fast shipping and the users install tips/notes are fantastic!! Will shop here again if I have to (have a Maytag washer that isn't draining and going into spin-bet the fix is on here somewhere!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- frank from Pittston, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Appeared to be too large at first...
At first the part appeared to be too large because of the change from one heater to two heaters in the replacement part. It was necessary to push a copper refrigerant line back out ot the way about an inch or so before the part would fit properly. This might take a little courage from the do-it-yourselfer, but it moved easily and seems no worse for the move. Currently the fridge is working well(two weeks) with no buildup of any frost on freezer panel as previouly noted. Overall experience was just fine. Makes d-i-y guy look good!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from Deerfield Beach, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Coils at back of freezer icing over
After reading posts on this website, I determined I needed to replace the defrost heater. Removed heater to take a closer look and after testing with a voltmeter determined it needed replacing. Ordered part online and could not believe how quickly it arrived. Blue wire that travels down the left side of the freezer coils had some damage on the end of the plastic connector so was pleased to find that I was able to splice the extension wire provided in the defrost heater kit onto the blue wire and dispose of the damaged end. It's been about 10 days and I do believe my problem has been solved!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Deborah from BRADLEYVILLE, MO
- Parts Used:
- WR23X37285
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Broken light switch
This was so easy I think it took me 2 minutes. I am not very mechanically inclined but that didn't matter! Works perfect thank you!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cynthia from Hillsboro, TN
- Parts Used:
- WR17X10060
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Temperature controller freezing vegetables.
I aligned the back of the controller with the slot in the icebox and it popped right back on. No more frozen vegetables.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Catherine from SEATTLE, WA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Glendale Heights, IL
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Light would stay on when door closed
Extremely easy repair, the hardest part was getting the old switch out. I used a pair of needle nose pliers to squeeze the tabs in and it came right out.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark Andre from FREDERICKSBRG, VA
- Parts Used:
- WR13X10020
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
Bottom part was broken and the door would not close on it own.
Followed the video on the computer. Was fixed in no time. Works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- C J from PARKER, AZ
- Parts Used:
- WR51X10101
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freezer frosted over and Rrigerator side would not maintain temperature due to failure of defrost heater
After viewing on Youtube I knew exactly what to expect in the repair process. It was easy, easy and saved me a 90 dollar service call plus an over priced replaement part. Time to repair was 25 minutes and included my kid taking the screwdriver.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Loren from EL PASO, TX
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
40 year old refrigerator brittle light switch fell apart
with a jewelry screwdriver I pried the lock tab in and pulled switch down carefully, the hardest part was that the power wire connector was stuck on good but the pliers and the jewelry screwdriver was its match for a bout 5 minute for one connection a simple pull off prong connection. After the wire connected back to switch it popped back in SNAPP
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from SUGAR LAND, TX
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light Switch Not Working - Needed New Switch
Remove the top cover above the door by lifting it slightly and pulling forward. I used a mirror to make sure that there was nothing in the way of accessing the switch from above. I used a blade screwdriver to press against the switch retainer on the topside, while GENTLY prying from below with another blade screwdriver to get the switch dislodged. Once the retainer was past the opening, I wiggled the switch downward and then rotated it to the left when the rounded top right edge of the switch was visible. This allowed the wiring to the connector to pass thru the hole. I pushed the wiring from the top and pulled from below to get the connector below the opening for the switch. I then unplugged the switch, plugged in the new switch and reversed the removal process feeding the connector thru first then rotating the switch to the right to get the rounded edge of the switch thru the opening, then pressed the switch up into the opening until it snapped into place. Total time less than 10 minutes.
Was this instruction helpful to you?
Thank you for voting!