Customer:
Roger from Colleyville, TX
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
No water through door dispenser
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Amazing.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tony from Conover, NC
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Wrench set
Water leak from the Water Valve.
I received my parts in 2 days, that is fast. It took me less than 15 minutes to install the unit. Now I've got ice and water from my refrigerator. Instead of taking expensive warranties, I would rather order parts from your company and do it myself on all my appliances.
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Anaheim, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
The icemaker quit making ice and the water started forming on the bottom of the ice bucket.
First I removed the electrical plug from the back of the freezer that plugs into the icemaker. I then removed the two hex head screws that hold the icemaker to the wall of the freezer and removed the icemaker. I removed the plastic cover, which incidentally protects the gears, by prying it off with a srewdriver. I removed three small nuts(7mm) which holds the internal cam in place. I removed the cam by pulling it off the shaft. Once I got the part from you folks I reversed the procedure that I just mentioned, and put the icemaker back together. It works great. The part with shipping was around $16.00. A new icemaker was roughly $159.00. If I would have called a technician it would have cost around $300.00 to repair.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Travis from Hillsboro, OR
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light Shield Broke Off
The light shield is only held in with a single screw, so it was the simplest install ever - unscrew the old light shield (in my case, the remaining piece of the light shield), put the new shield in place, and screw it down. Doesn't get any easier than that.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
bryan from miamif, FL
Parts Used:
WR17X4312
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
ice maker was rusty
i ordered this ice maker on sunday night and paid for the cheapest shipping. it got here monday morning and i couldnt believe it. super fast shipping!! works great
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Grapevine, TX
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
water dispenser/ice maker wouldn't work
Unplugged refrigerator and turned off water valve at wall. Removed the entire back, lower cardboard panel (turns out I didn't have to do this...could have just removed the screws from the right side and folded the cardboard along a perforated line designed for that purpose). Removed screw holding water control valve to back of refrigerator. Took new control valve, and slipped on adaptors for electrical connectors (in bag) to the two smaller of the four electrical prongs). Removed electrical sockets from old connector and placed them over appropriate prongs on new connector. Unscrewed the two old water out lines, cut the old fittings off and slipped the lines snugly into the new outlet valve (new valve had slip on connectors not requiring lines to be screwed in). Keep straight which line goes to which outlet port! Then removed water line going into old fitting and screwed it on to new valve inlet fitting (after removing black plastic protective cap). Turned wall water valve on, checked for leaks (none), and plugged refrigerator back in. Water restored to both icemaker and water dispenser!

By the way, the first valve came damaged, but one phone call and the people at Part Select promptly sent out a replacement which I had the very next day (and this was two days before Christmas!). Great job!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Walter from Wyndmoor, PA
Parts Used:
WR17X4312
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker crushed all ice and would not make cubes. Pushing the switch and changing to cubes did not work.
Removed old ice bucket with auger. Unscrewed front plates that form the front of the ice bucket. Replaced the front plates on the new part (ice bucket and auger). Replaced new assemblage. It took about 20 minutes. Had to empty ice out and put in a temporary cooler for storage. Bigger problem than the repair was diagnosing what was wrong. Pushed disagnose button and it said ice maker was working normallly. Careful examination of the ice bucket removed from refrigerator showed spring out of place on long metal rod that protrudes from the back of the ice bucket and fits into a square hole in back of refrigerator. Examined other end of rod that engages with plastic parts that run the ice auger and ice crusher mechanism. A piece must have broken off. That was the problem. Refrigerator ice maker now works fine as originally designed. Push crudh the ice crusher engages and you get crused ice. Push cubes and the icemaker crusher slides out of the way and you get cubes.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Mechanicsville, MD
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
Leaking Inlet Water Valve
Very quick and easy repair. Took off cover to access valve using standardr screw driver. After shutting off water supply to valve disconnected copper water supply line. Used a large towel to catch any residual water in line. Removed two water lines on valve use plies if more than hand tight to loosen. Removed screw holding valve in place, removed valve and disconnected wires (be sure power to frig is off least you get a shock. Reverse proceedure to install new valve. new valve has simple push in connections for plastic water lines. Install two electrical adpaters and electric lines. Mount valve with screw, connect copper water line. Turn water back on and check for leaks. Turn power on and check for proper water running at dispenser. Again check for any leaks. No leaks, install cover and you are done.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joey from Travelers Rest, SC
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
The water valve was leaking
I Took the six screws off the back panel to get to underneath the refridgerator. took the 2 screws out of the bracket thast holds on the water valve took the 2 lines off and then put everything back
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rehn from Austin, TX
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
Ice maker would not work
Disconnected the power and then the water line. Removed the cardboard shield on back of the refrig. Then removed the faulty solenoid which was held in place by one bolt. Removed the two plastic water hoses and two sets of electrical connectors. I then reversed the process to install the new solenoid. I encountered two challenges. The new solenoid had a plastic housing that had to be removed and one set of the electrical connectors required an extension. The extensions were included with the solenoid, but there were no instructions.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from HAYMARKET, VA
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper was worn and misshapen allowing warm air in freezer, ice cubes to melt and drip and impairing function of ice dispenser. Frost formed in ice dispensing chute also.
Followed the online video. Unplugged refrigerator, removed trim piece, lifted control board cover, removed 4 screws retaining circuit control board and removed the 3 connectors from the control board. Located flapper and removed by using small flat tip to take tension off flapper connectors. Helper held flash light to illuminate flapper connectors. Reversed procedure. New flapper seals well and cured problems. Circuit board was a bit different than one in video, but still had the 3 connectors. Marked each connector with grease pencil at top edge to ensure correct reconnection. Should note how wires are threaded around circuit board to ensure they are tucked back in correctly in reassembly. Remove trim piece carefully. I broke 2 of the 8 plastic pins that hold trim on. May be due to age of unit as they were brittle. 6 pins still hold trim piece flush.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henderson from Holladay, TN
Parts Used:
WR57X10051
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
After the ice dumped, the tray would overfull and run over into the freezer
The operation is very simple on this valve. I disconnected the water lines and wires.
Then two I removed the two screws attaching
valve to the ref.box.
The reinstall is just the opposite from removal.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rudy from CITRUS SPGS, FL
Parts Used:
WR17X11653
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Had a drip which filled up the tray and leaked on the floor from water dispenser
There are Great videos on YouTube!!! Turned off power,Removed trim ring, Pushed a philips head screwdriver in one of the holes underneath the electrical panel with the selector push buttons. This releases the electrical panel. There are Three wire sets with plugs. I removed the plugs and took the electrical panel out. Removed four Phillips head screws and pulled out the big paddle switch. This then exposes the flapper. Replaced flapper with new one and reassembled everything. When I had everything apart, I cleaned with window cleaner. It was pretty moldy from the water leaking. Turned power back on and tested everything to make sure I didn't mess anything up. Works great
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
anthony from DUMFRIES, VA
Parts Used:
WR57X10051
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
no water going into ice maker
follow the video
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from FIFE LAKE, MI
Parts Used:
WR30X256
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Plastic guide in rear of bucket broke it guides auger when dispensing ice
I simply removed 6 screws that held bucket to face and pit on new bucket and put it back in freezer works great
1 person found this instruction helpful.