TPG21KRYFWH General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Chris from Houston, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice flapper replacement in freezer door
Looked at the instructional video and read previous customer comments. Didn't have to dissassemble rear of freezer door. Access through the front once trim ring and circuit board removed. Could not have done it with out the video/and or previous customer comments. Part was shipped and received immediately. Repairs complete! No more frost developing and plugging ice chute! I especially appreciate the customer comments on how to complete this repair!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Mooresville, NC
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Dispenser Door Seal not sealing, frost in freezer
Googled how to replace the door seal, ordered parts and replaced the door seal flapper. The video on partselect was not correct for this GE model. However a simple diagran showed you simply remove the control panel directly (pops off) to provide access to the panel. Remove the 4 screws holding the panel, replace the door seal, and reassemble.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Austin, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Heavy frost was forming where ice is dispensed
Watched the PartSelect video. Very simple and solved the problem. Very pleased with the repair and PartSelect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harold from Concord, CA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Frost in and around ice maker outlet
Followed the video directions. Spent about 5 minutes and I was done. Very easy to do. Problem with frost is gone. The video makes it easy to remove the plastic parts without any damage.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Theresa from Grand Blanc, MI
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
We had ice crystals on the ice tray and door
Removed the ice maker control panel and accessed the flapper door, easy switch out for new door and seal. The 2 year old warped seal didn't close and so ice crystals formed in the freezer - new unwarped part and Ta-Da no more problems :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brenda from Little Elm, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Frost buildup in the freezer near the ice chute.
I watched the video on the PartSelect.com website and decided to give it a try. The replacement of the flapper was even easier than I anticipated! The old flapper was extremely warped and was allowing air into the freezer. I'm not sure how/why it was in that condition but I am happy to report that I have no more ice buildup. Thank you, PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Craig from Nags Head, NC
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
flapper was locking open periodically.
Replaced flapper, which was in surprisingly good condition. Major part of repair was removing a lot of mold incurred from long term seepage of room air into the ice channel. In the process of the repair, I discovered that the solenoid to the right of the flapper was hanging up badly. I removed it and cleaned both the plunger and the interior cone of the solenoid with alcohol. This removed quite a bit of rust and some mold. Reinstalled solenoid, replaced flapper and it works just fine. May need to replace solenoid if problem recurs. Certainly worth $37.00!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Paducah, KY
- Parts Used:
- WR30X256
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Collar that holds Ice auger assemble was Broken.Seems to be a manifacturing defect in this model.
I simply ordered a new Ice bucket, removed about 6 Phillips head screws, removed the old bucket from the Ice door and replaced with a new bucket. SIMPLE !!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Fripp island, SC
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
3rd Flap for this Ice Mkaer, keeps warping
Very Easy, follow direction I the video.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roy from Paso Robles, CA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker flapper
Your Video really made it easy, showing the actual replacment of the part. However I did have one problem, which was I could not unplug the panel just by pulling on the plugs. A locking catch is on each plug so I just moved the panel out of the way.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jon from social circle, GA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
frost formed because the ice damper let warm air into the freezer
Removed frame, unscrewed the electrical panel, and popped the flapper off. Installed new flapper. Replaced the electrical panel and re-installed the frame.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- DON from ZELLWOOD, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Shute Flapper Was Distorted And Did Not Seal Opening Causing Frost Build Up
Removed control panel by inserting small screwdriver in the 3 holes underneath to loosen. Remove 4 screws holding circuit board . Unplugged 3 connectors. Removing circuit board gave access to flapper. Removed flapper by unclipping. Installed new flapper and reversed disassembly procedure. This was 2nd time in 2 years I had to replace this part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Marietta, GA
- Parts Used:
- WR17X11653
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Frost inside freezer door and water dispenser line freezing
I followed the video instructions (very helpful) and used others comments for removing the control panel. For the latter I used a small allen wrench to carefully wedge the bottom two indents (look from below panel edge) slightly up and forward to release the panel. Next, after removing the four screws, the assembly (housing shield) removed fairly easily. I then had full access to the flapper and removed this carefully with the pliers so as not to damage the piece it was attached to (Dispenser Door Recess Crank?). The rubber outer flange on the otherwise plastic flapper was very irregular for approx. 1/4 of the circumference and thus did not seal. So far it's been one week and no more frost build up or frozen water dispenser line.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald J from Seabrook, SC
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Flapper door mis-shapened
Took the paper clip, pressed in through the holes on the bottom of the ice dispenser panel. Removed the four screws. Loosened the panel and removed the wires. replaced the flapper door. Then reversed the process. Your video was VERY helpful except for the paper clip. Had to get that off another web site.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jack from Ft Myers, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
air leak from ice maker flap permitting frost buildup inside ice maker dispenser
Watched à video provided at your website. Removed te cover then removed 4 screws holding the control panel' snapped out the old flap and inserted the new one.
Was this instruction helpful to you?
Thank you for voting!