PHG25MGTAFBB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Theodore from San Gabriel, CA
- Parts Used:
- WR50X10068, WR17X11843, WR55X10025, WR02X10668, WR02X10647
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
refridgerator was not defrosting & so was getting warm
On the PartSelect website, I chose the 'refridgerator is too warm' problem choice. The site sugested replacing the sensors so I purchased them. The drain trough on the refrigerator side was leaking and it and the defrost thermostat were not too expensive so I bought them too.
Once the parts arrived I installed them. I had already disassembled the inside of the freezer. The sensors and thermostat had to be connected electrically. So I cut off the old parts and stripped their wires. (the new parts' wires were already stripped.) I then used wire nuts to connect the new wires to the old and stuffed the wire back into its compartment and installed its cover. The defrost Thermostat has to be clipped to the refrigeration line. So after attaching its wires I had to work it into its place.
I then reassembled the inside of the freezer and let it sit for an hour before turning it back on. Once it was turned on it seemed to work well, but after only 3 or 4 days the coils began freezing over again.
Once the parts arrived I installed them. I had already disassembled the inside of the freezer. The sensors and thermostat had to be connected electrically. So I cut off the old parts and stripped their wires. (the new parts' wires were already stripped.) I then used wire nuts to connect the new wires to the old and stuffed the wire back into its compartment and installed its cover. The defrost Thermostat has to be clipped to the refrigeration line. So after attaching its wires I had to work it into its place.
I then reassembled the inside of the freezer and let it sit for an hour before turning it back on. Once it was turned on it seemed to work well, but after only 3 or 4 days the coils began freezing over again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- roy from spring hill, KS
- Parts Used:
- WR02X10552
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
going from warm to to cold
i used the video it showed on the site or iwould not have been able to do it
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ron from Winter Haven, FL
- Parts Used:
- MWFP, WR17X11655
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
filter replacement/water tray replace
remove by hand turning old and replacing new by turning by hand.Lifted out old grill and placed in new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Laura from Manchester, NH
- Parts Used:
- WR02X11330
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Columbia, CA
- Parts Used:
- WR11X10010
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Feezer door would not always seal
Because the lever was broken, when you close the refrigerator door, the freezer door would unseal slightly causing frost to build up on the inside and outside of the door.
After removing the base grille, the repair was made by simply placing the new part in the slot where the old part was then re-attaching the spring from the part to the hook in the base of the refrigerator. Now replace the base grille with the two screws. Time: About 10 minutes. Tools: Phillips screwdriver, needle nose pliers.
After removing the base grille, the repair was made by simply placing the new part in the slot where the old part was then re-attaching the spring from the part to the hook in the base of the refrigerator. Now replace the base grille with the two screws. Time: About 10 minutes. Tools: Phillips screwdriver, needle nose pliers.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David G from Walpole, MA
- Parts Used:
- WR17X11459
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
replacing ice maker drive dispensing cup
followed instructions already posted on your website, but had a very difficult time getting the dispensing side of the auger assembly to slide out, even after I disengaged the plastic tabs. There is no easy way or place to grab the assembly to pull it out. Finally turned the unit upside down and pounded on the edges of the assembly with a wood block and a small hammer. Once the part started coming out a couple of inches, I flipped over the ice bin and was able to pull it out the rest of the way, once I had something to grab on to. After the auger assembly was out the cup replacement was easy per posted instructions and the unit snapped back together easily.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- mike from Aguilar, CO
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from CANOGA PARK, CA
- Parts Used:
- WR60X10307, WR62X10055, WR50X10068, WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
The tempeture for both the freezer and the fridge would be all over the place
Troubleshot the tempeture sensors and the resistance was alot lower than the specs called for had to replace the evap fan being 1 of the sensors is connected to the evap fan . Start by removing all the food from the.freezer and bottom section of the fridge . Remove all the shelves and bins in freezer and shelf and drawers.on the lower section of the fridge .remove the ice bin , and the ice.machine remove the light shroud, and.bulbs, push tabs on the light sockets and pull the sockets from the housing.. and then push the sockets through the holes of housing remove all the screws from the rear wall from top to bottom upon removal of the section just under the ice.machine and behind the light socket you.will find the evap fan and it's bracket remove the 2 screws and pull straight up on the fan blade be carefully to not break its best to pull from the center of fan blade .remove the clip and thermistor that's connected to top of the evap coil. While your there remove the defrost thermostat to do this the clamp that holds it to the coil is a split clamp and you gently push on the clamp upper section and pull the lower section and it will seperate enough for you to remove the thermostat the other thermistors are in the fridge section 2 are on the divider wall behind the plastic oval plastic.housings one just above the the middle.of fridge the other is.lower section. And finally 1 more is at the very bottom of fridge last drawer on right hand side to.remove this you need to remove the light cover. Remove the plastic half round plastic deflector and the foam behind it remove the water reservoir screws and open the freezer at the bottom center wall at the back is a round plastic damper cover with a Phillip screw remove that ,on fridge side remove the 4 screws that hold the lower damper housing to the bottom of fridge gently and slowly work your way around the center seam and aeperate the upper cover of damper housing and expose the thermistor and replace. Note on all the thermistors just cut off enough to splice in replacement I personally used water tight heat shrink soldered type butts work great
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Graeme from Sarasota, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Icemaker flap not closing, frosting up
Watched video, however could not get outer casing off. Under the panel are three small holes, pushed up with an Allen key, used a small screwdriver to wedge out, came out easily, followed instructions from video on removing and replacing solenoid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- EDWARD from INDIAN WELLS, CA
- Parts Used:
- WR23X31507
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Fresh food section lights were all out, but the bulbs tested good elsewhere.
I popped the switch out using the blade of a small screwdriver and noticed that it connected with two wires via a slide on connector for each one. I noted the info on the old switch to identify which wire went to which terminal. I held each wire with a pair of pliers while I pulled the wire connector off the terminal on the old switch. I connected the two wires to the correct terminals on the new swith, and popped the switch back into the door frame. Easy, easy, easy and saved the $40 service call + parts cost!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tim from The Woodlands, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stella from Puyallup, WA
- Parts Used:
- WR01X37886, WR17X11459
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Drive cup broke, light went out
Just had to pull ice maker drawer out and replace the drive cup which was very simple. Light bulb on door dispenser was kind of hard to get back in cause it is such a small space to screw the bulb in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leslie from BEND, OR
- Parts Used:
- WR17X11843
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Rusty water on refrigerator floor
turned out to be a rusty drain pan in the refrigerator section behind the fan fixture attached to the wall.I followed the instructions of a prior customer on the website and it worked like a charm. Super happy to have done it myself!! Can't believe they don't use plastic for this part as it would rust again if I didn't coat it with the rustproofing spray.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- scott from lake orion, MI
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker door not opening
Removed panel from front of freezer door by pushing up on three spring loaded screws located in the opening where the ice door opens and closes. they are about 1 inch apart on the bottom of the opening. Push up to free ice maker panel. Remove three screws from solenoid, located at the top right. Remove wire, replace with new and that is it. Fixed the problem!! Our ice maker hadn't worked for months. Be careful if you remove the round ice maker door to clean. There is a spring that located on the left side of sprocket. The spring fell off and took me a while to figure where it came from. Recieved package in three days and the job took minutes. Works great! Very easy to complete.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Arvind from Port Saint Lucie, FL
- Parts Used:
- WR17X11459
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
the drive cup on the auger had broken in half, no ice dispensed
Removed four screws holding the bin ontomain body. lifted the auger enough to slip in the new cup and placed the bin into the main body and installed the four screws back. Put the bin back into the Freezer. it work just fine
Was this instruction helpful to you?
Thank you for voting!