- Customer:
- Carl from SAN MARCOS, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker Leaking
Researched on internet/you tube; ordered part, and did the repair. Easy to do and saved the cost of a service call.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christine from Delray Beach, FL
- Parts Used:
- WR17X10542
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
drawer facing cracked
ordered drawer face - perfect part- snapped right in. done. order came within 10 days.
will order again if needed.
will order again if needed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jimmie from Surprise, AZ
- Parts Used:
- 7C7
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Bulb burned out.
Screwed new bulb in socket
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ruben from Sylmar, CA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Leaking water
Be careful when ordering the part. Make sure you need a Double or Single Outlet Water Valve. They look almost the same in the catalog.
Unplug the power cord and turn off the stopcock water supply valve. Unplug the 2 electrical jacks and pull-out the water hose from the compression type fitting. Use a philips screwdriverdriver to remove the bad part. Install the new part in the reverse steps.
Unplug the power cord and turn off the stopcock water supply valve. Unplug the 2 electrical jacks and pull-out the water hose from the compression type fitting. Use a philips screwdriverdriver to remove the bad part. Install the new part in the reverse steps.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephanie from DENVER, CO
- Parts Used:
- 7C7
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
drum light burned out
removed the bulb from the package unscrewed the old bulb & screwed in the new bulb.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from BRICK, NJ
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
My ice container and Ice chute were freezing up and getting blocked, and my filtered water line was also freezing
I just followed the instructions on the video and it was exactly as they said......no surprises.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Poquoson, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
My icemaker was leaking down the back wall of the freezer (side-by-side unit) building a huge ice flow that grew into the path of the circulation fan.
After turning the water off, I removed the two screws holding the cover on the lower back of the freezer. I disconnected the copper water supply line from the valve. I then removed the screw holding the valve in place and removed it from the freezer. I removed the two wires from the valve and placed them on the new valve (after inserting the clip inserts to match the new size tabs).I pulled the two plastic water lines out of the valve and inserted them into the new valve. I put the new valve in place and replaced the screw. Total time less than 15 minutes. Much easier to fix, than to identify the problem. The collective wisdom of the internet strikes again! Thanks to all.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Cun City Center, FL
- Parts Used:
- WR17X3909
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The shield light had burned the shield
I hung the new shield on the two inside pegs that were already there.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Al from River Edge, NJ
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker discharge was slow and jammed with ice and frost. The cause was a distorted flapper that did not seal properly, admitting warm air into the dispenser chamber.
Excellent video was available on the Parts Select website. It was simple. The selector panel pulled out by hand from the bottom. The subpanel was removed with the four screws. The flapper snapped out of the holder with two clips. The new one was inserted in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chester from Chambersburg, PA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Valve leaked water and needed to be replaced
First I removed the incoming water line from the valve. I then removed the screw that hold the valve in place. Then I pulled the element out about 3 inches and disconnected the two connector wires. Next I cut the plastic hoses from the old valve.
To install the new valve, I inserted the two plastic hoses into the new valve. (hoses are different diameters so it is next to impossible to insert them incorrectly.) I replaced the electrical connectors (This was the only glitch since the one connector on the refrigerator is larger then the pins on the new valve, A little electrical tape held the connector in place.) I then tightened the screw that holds the valve on the refirgerator and reconnected the household water to line to the valve.
The entire job took less time then it has taken me to type the procedure.
To install the new valve, I inserted the two plastic hoses into the new valve. (hoses are different diameters so it is next to impossible to insert them incorrectly.) I replaced the electrical connectors (This was the only glitch since the one connector on the refrigerator is larger then the pins on the new valve, A little electrical tape held the connector in place.) I then tightened the screw that holds the valve on the refirgerator and reconnected the household water to line to the valve.
The entire job took less time then it has taken me to type the procedure.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Somerset, KY
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set, Wrench (Adjustable)
water wouldn't shut off
replaced solenoid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Craig from Land O Lakes, FL
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Water flow was too low
Turn off water valve to the refigerator and disconnect line.
Remove the cardboard backing and insulation.
Remove old valve and cut lines close to the valve.
Trim plastic on new valve as needed to fit (generic valve).
Insert water lines into new valve.
Install new valve.
Connect water line and open valve.
Replace cardboard backing and insulation.
Remove the cardboard backing and insulation.
Remove old valve and cut lines close to the valve.
Trim plastic on new valve as needed to fit (generic valve).
Insert water lines into new valve.
Install new valve.
Connect water line and open valve.
Replace cardboard backing and insulation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GARY from LIVONIA, MI
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Maker Clogging up from frost build-up
Turn off power
Remove operator faceplate by pullling out on outer lower corners
Disconnect wire connectors from circuit board
Remove four screws from dispenser and pull out dispenser assy
Replcae Door ASsembly
Put everything back in place
Power up
Job Done
Remove operator faceplate by pullling out on outer lower corners
Disconnect wire connectors from circuit board
Remove four screws from dispenser and pull out dispenser assy
Replcae Door ASsembly
Put everything back in place
Power up
Job Done
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ken from Wesley Chapel, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
froze in freezer
unclipped and replace with new part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- joselito from riverview, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Building Up In The Ice Dispenser Chute
Under the control panel there are three small holes. Insert ballpen or small flat screw driver on both outer holes to push a tab lock that holds the control panel in place. Then pull out control panel and three set of wires will be exposed and disconnect wire connectors (connectors have different sizes so you wont get confused in reconnecting). Unscrew four screws on each corner that holds the ice dispenser assembly (a part where you push your glass against to dispense ice or water. The flapper is exposed and easy to replace.
Was this instruction helpful to you?
Thank you for voting!