Customer:
Ron from ORANGE, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Unit had stopped making ice
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from ZIONSVILLE, PA
Parts Used:
WR17X11168
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
water line (from the PS304374 Dual Inlet Water Valve) to the ice maker was craked and leaking
1. Removed the back panel of the fridge to get access to the inlet water valve.
2. Removed black poly water line from valve (pull back on white ring where line is attached and pull the line out)
3. Removed the inlet tube from top-back of fridge (where it goes into the ice make). use putty knife to get under the sticky white gasket beneath the black oval housing and pull the tube out form the back of the fridge.
4. Replace the water line with new part taking care to properly seat the line into the the bottom water valve and pushing the water tube into the hole for the ice maker.

Note: Be sure to take off the protective covering from the white - sticky grommet and push to adhere to metal on fridge.

to be safe - use a bit of clear silicone chaulking round the perimeter of the grommet and push to tighly bond the water inlet tube to the fridge.

The reason for this - is that if you do not get a good bond using the white - sticky gormmet alone - you may have the water tube inside the ice maker freeze up.

Also once the new water line is installed be sure to secure the line to the metal back of the fridge - so the line will not move. some fridges come with metal hose clamps to do this - otherwise use duct tape
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jake from Brainerd, MN
Parts Used:
WR57X33326
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Wrench (Adjustable)
Ice maker inlet tube was freezing up, and eventually the icemaker overfilled and completely froze up
After lots of research online, i narrowed my problem down to be the double outlet water valve, behind the fridge. My biggest problem was getting the refridgerator out of its spot, but after that it was pretty simple to change. I took the cover off the bottom, in the back of the fridge, then i removed the inlet waterline (after i turned off the water supply to the fridge). After that i removed the screw that holds the valve to the framework. Now i pulled off the two other waterlines from the old valve and moved them, one at a time, over to the new valve, along with the wire harness. The rest of the instalation was reverse order. Simple fix that im glad i didn't pay an expert to do!
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bob J from Platte City, MO
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Water not dispensing
Background: My refrigerator was part of the class action law suit back in 2006. As a result both doors, the auger in the ice maker and a heating element in the freezer were all replaced.

Problem this time: Water was not dispensing.

Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.

Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.

However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from White Pine, TN
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Would not cool top or bottom
Everything looked to be working but the compressor. As a pro checked every thing came down to a relay on the main board.

Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Keller, TX
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frances from Beavercreek, OH
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Refrigerator light not coming on
Our daughter spilled juice on the refrigerator light button. It started with the light coming on very slowly and then not at all. We popped off the old button with a flat head screwdriver, plugged in the new one. Works perfect. Can't believe how inexpensive and easy the fix was.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeanne from Milledgeville, GA
Parts Used:
WR71X10764, WR12X10625
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Items were broken
Really easy to install - they both snapped into place.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
louis from floral park, NY
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
evap fan not working.
first i removed the three screws that covered the circuit board that was bad. then i removed the 6 connectors that went from the refrigerator to the board then popped out the old board , popped in the new board reconnected the circuit connectors covered everything back up and my refrigerator is back on line. this all took about 10 to 15 minutes time ... thank you for your product it really did the job..
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Summer feild, FL
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
cold water dispenser would not stop running
Turn off the water.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice.
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chip from Mandeville, LA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.

p.s. I didnt use any tools, but to satisfy you I select nut driver.
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
nancy from Mt. Washington, KY
Parts Used:
WR57X33326
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
Was not getting water to the door.
Moved refrigerator out from wall, unplugged from electric, removed plate at bottom back with 1/4 nut driver, turned incoming water valve off, disconnected water line from water valve on refrigerator, removed mounting screw, remove water lines from valve and electrical plugs, set old valve aside and replace with new valve, reconnecting water lines and electrical plugs then remount bracket, reconnect water line from source, open water valve and check for leaks, replugged refrigerator and depressed the door button to check to see if working. It worked and there was not any leaks. Replaced back plate and placed refrigerator against wall. Job completed.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Sylva, NC
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Ice cubes froze in the tray and frost was all underneath
I read stories from the website how others did it so I figured I would give it a try. I put all the frozen stuff in the refrigerator piled up. Took out the shelves. Took out 2 screws with a socket extension ( nut driver will work fine.) Remove the light bulb. lifted up on the back panel...it came right out. Saw the coils and on top the sensor. Took it off, cut the wires, spliced in the color coded new one ( pink to pink, orange to orange) Stuck it in the top coil in the original position and crossed my fingers! I put all the pieces back easily, restocked the freezer and waited. HOORAY!! My ice cubes are all separate and free. NO frost inside. A very easy fix for $20.

Note: If there is a large amount of ice build up on your coils a hair dryer works great. The drain is on the bottom anyway. Also , you may want to seal around the wire nuts to keep moisture out. I did
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Clifton, VA
Parts Used:
WR32X26198
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken Drawer
All I had to do was slide it in. But that's not what made me so thrilled with your site. What won my devotion was your site's ease of use (I couldn't find what I was looking for on GE's site) and the promptness of delivery. I will certainly use you again and recommend your services to my friends!
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kyle from LAPWAI, ID
Parts Used:
WR17X11168
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Wasn't making ice
1. I unplugged the refrigerator/ freezer
2. Turned off water supply
3. Removed the screws that held the cardboard skirt in place
4. Unplugged the water tube from the push connect
5. Removed the screws around the water inlet to the ice maker
6. Remove the water fill tube
7. Install new water fill tube and put all the screws and plates back where they go
4 of 4 people found this instruction helpful.