Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
David from Arizona City, AZ
Parts Used:
WR17X11263
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Replaced broken auger
After retuning the wrong part and then recieving the correct part it was fairly simple to change the auger. The only thing to be carefull about is keeping all the ice crusher parts together in propper order. also the nut on the front after removing clip has left hand threads.
12 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Columbia, CA
Parts Used:
WR11X10010
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Feezer door would not always seal
Because the lever was broken, when you close the refrigerator door, the freezer door would unseal slightly causing frost to build up on the inside and outside of the door.

After removing the base grille, the repair was made by simply placing the new part in the slot where the old part was then re-attaching the spring from the part to the hook in the base of the refrigerator. Now replace the base grille with the two screws. Time: About 10 minutes. Tools: Phillips screwdriver, needle nose pliers.
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from Loganville, GA
Parts Used:
WR17X11497
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Cover was cracked affecting ice dispensation
Removed the ice tray and then the auger unit from the tray assembly. To accomplish auger removal, the auger assembly is attached to the tray assemble at the front. On the front bottom there two screws. Back them out. Then on the top of the tray assembly the auger assembly is held in position by two tabs. Depress them with a finger or thumb. Do not use a screw driver as this may result in breaking the plastic tab! The auger assembly will separate. The crusher plate easily separates from the auger assembly and is removed buy "spiraling" the plate up and off the auger itself. Simply reverse to install new plate.
Recommendation: Take this opportunity to thoroughly clean and COMPLETELY DRY all components prior to re-assemble and re-install into the refrigerator.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Graeme from Sarasota, FL
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Icemaker flap not closing, frosting up
Watched video, however could not get outer casing off. Under the panel are three small holes, pushed up with an Allen key, used a small screwdriver to wedge out, came out easily, followed instructions from video on removing and replacing solenoid
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
EDWARD from INDIAN WELLS, CA
Parts Used:
WR23X23343
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Fresh food section lights were all out, but the bulbs tested good elsewhere.
I popped the switch out using the blade of a small screwdriver and noticed that it connected with two wires via a slide on connector for each one. I noted the info on the old switch to identify which wire went to which terminal. I held each wire with a pair of pliers while I pulled the wire connector off the terminal on the old switch. I connected the two wires to the correct terminals on the new swith, and popped the switch back into the door frame. Easy, easy, easy and saved the $40 service call + parts cost!
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tim from The Woodlands, TX
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
scott from lake orion, MI
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Ice maker door not opening
Removed panel from front of freezer door by pushing up on three spring loaded screws located in the opening where the ice door opens and closes. they are about 1 inch apart on the bottom of the opening. Push up to free ice maker panel. Remove three screws from solenoid, located at the top right. Remove wire, replace with new and that is it. Fixed the problem!! Our ice maker hadn't worked for months. Be careful if you remove the round ice maker door to clean. There is a spring that located on the left side of sprocket. The spring fell off and took me a while to figure where it came from. Recieved package in three days and the job took minutes. Works great! Very easy to complete.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
inessa from manalapan, NJ
Parts Used:
WR23X21444
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
frezer door light switch broke (I have 2 boys :)
The repaire guy came in tooke it out and told me it is goin to coast $20 for the part and $50 for the labor..... So I looked, It was soooo eeezzz ALL you have to do is get the switch out( with help of my butter knife :) it plugs in to a little outlet on the wire (on the botom side) so take out the old one and plug in the new one wich I got for $8 + $6 shipping = $15 THANK YOU PART SELECT for saving me $55 Im a 36 y/o stayathome mom and Ihave never don this before, Im very proud of my self. well... it was very easy!
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherrie from COTTLEVILLE, MO
Parts Used:
WR24X20455
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Worn out gasket on freezer
I received part. I then used a hair dryer to smooth out kinks. Took about 15 minutes. Pulled off old gasket and replaced with new one. Used hands only.
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Nazareth, PA
Parts Used:
WR01X10315
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Groove for retainer clip on auger nut was broken out.
After removing three screws on the ice bucket, it basicly came apart by itself. I needed to use pliers to remove the old nut because it had over tightened itself onto the shaft. Be careful here - it is a left hand nut - not a normal right hand nut! Reassembly was a snap putting the parts back together in reverse order. Unit has been working great since the repair.
13 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
M from STERLING HEIGHTS, MI
Parts Used:
WR02X13425
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
My Door Stop Broke
I had to remove 2 screws to get the broken door stop off then I put the new door stop on by using the 2 same screws.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Mount Prospect, IL
Parts Used:
WR23X23343
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light switch shorting out causing open door alarm to go off
Easy fix, but they don't give you plenty of wire to work with. When I pulled the switch out it only had about an inch of wire that came with it. meaning if I didn't have a grasp on the wires as I was removing the switch they would have slipped back up the opening
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ricky from Virginia Beach, VA
Parts Used:
WR02X45206
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
Low water flow from indoor water dispenser
Disconnect main water line from behind refrigerator
Remove bottom panel from refrigerator
Disconnect hose from water valve
Remove metal hose guard from top left of refrigerator Carefully remove plumbers putty from around filter hose (you will be reinstalling this putty around new hose assembly)
Inside refrigerator remove MWF water filter and guard, and then remove two screws holding filter assembly in place (this requires socket set with 4” extension bar)
Carefully pull filter hose assembly towards you from front of refrigerator. Once assembly is out remove Styrofoam cover from old assembly and install on new assembly
To reassemble, simply follow this process in reverse. Good luck
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frederick K from Kingston, TN
Parts Used:
WR49X10091
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
GE Profile Arctica food locker was below freezing
The trouble shooting information on the web site indicated that the damper door within the climate control unit may be broken. This was easily confirmed and the replacement of the climate control unit immediately returned the food locker temperatures to the digital electronic thermostat settings. The part has an improved ventilation gasket interface between the food locker and freezer. The unit works perfectly again, and the food locker temperature is exactly what the thermostat setting is.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Pinehurst, NC
Parts Used:
WR13X10215
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
The door when opened had swung back and made contact with the hinge. Over time it had bent the hinge upward so the pin was coming out of the door and it was not closing (sealing) properly.
I removed the screws out of the hinge while my wife put pressure on the door to hold it in place. I removed the hinge, replaced it with a new one, and screwed it back in place. Took just a couple of minutes. Easy and fast. The refrigerator was not leveled properly and that was why the door had swung back so fast, with enough force to eventually bend the hinge. I contacted geappliances.custhelp.com and used the chat option to speak to someone about how to lower the back wheels. They were extremely helpful in walking me through it. Now the refrigerator is leveled, and the door, when opened, will not swing back and contact the hinge. My overall experience in fixing this problem, from locating and ordering the correct part, to installing it, and then fixing the problem that led to the hinge being damaged in the first place, was outstanding.
6 of 6 people found this instruction helpful.