PHE25YGXAFWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Shelly from WATERLOO, IN
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The ice flapper would not go close .
remove the front of were the ice and water comes out
then un scerw 4 scerw and the solenoid slides out unhook the wires and put the new one in
then un scerw 4 scerw and the solenoid slides out unhook the wires and put the new one in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert J. from Darlington, SC
- Parts Used:
- WR71X10764
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
Broken shelf insert
Snapped it into place. Nothing to it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from Littleton, CO
- Parts Used:
- WR23X31507
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The Light Would Not Go On
Knew the switch was bad. Researched on the internet how to fix. Used a steak knife to pop the old one out, changed the contacts to the new switch and popped it back in. It took longer to open the box than it did to replace the switch. And the part arrived 2 days after I ordered it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from auburndale, FL
- Parts Used:
- WR71X10764
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
broken door bin
looked up the part on your site which was very quick and easy. Ordered the part and it came quickly and my installation was just as quick. Greatful for your web site Regards John
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roger from Colleyville, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
No water through door dispenser
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Amazing.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Los Angeles, CA
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Door flapper would not self-close
I replaced the original solenoid, which had rusted into one solid piece. OMG how easy was that!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Torrance, CA
- Parts Used:
- WR17X11459
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Drive does not turn ice dispenser helix; No ice dispensed
Remove tray screws, leverage helix out of drive hub and insert new cup.
I'm looking for a replacement on guarantee.
I'm looking for a replacement on guarantee.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bryan from Fairfax, VA
- Parts Used:
- WR62X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freezer frosting up around ice dispenser chute.
Ordered new solenoid so the flap would close. That did the trick.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Lacey, WA
- Parts Used:
- WR17X11505
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Icemaker parts were cracked after use
I had to replace the whole tray. Required complete disassembly and reassembly. Simple to do. No problems whatsoever!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Amy from Henderson, NY
- Parts Used:
- WR29X10085
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
ice maker was making no ice.
snapped in the new stripper arm where the defected one was.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Robins, IA
- Parts Used:
- WR62X10055, WR17X11653, WR23X10783, WR17X10706, WR02X10585
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Ice chute flapper would not close all the way
Following the advice of others on this site, I popped out the control panel by pushing up through the 2 outer-most holes on the under-side of the panel (the middle hole is unused). I installed the new solenoid exactly as shown in the PartSelect video. The new crank, spring, and flapper installed easily as well; I did apply a little grease to the hinge points on the crank to ensure no binding. I also installed a new microswitch. The wires are best removed from the old switch with a needlenose pliers. The old switch looked like it had some grease on the switch (where it makes contact with the cup lever) so I put some grease on the new switch as well. All-in-all, very easy and the frig works like new. It's nice to hear the flapper slam shut 4 seconds after dispensing ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from ROSEMOUNT, MN
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rick from VACAVILLE, CA
- Parts Used:
- WR17X11653, WR17X10706, WR02X10585
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
ice door not closing
looked at the video you supplied for repair.. that made it so easy to repair the problem. I felt quite confident in myself after the video.The repair went smoothly and the refridgerator wotks super thank you so much Rick
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from st aug, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
the cecular door for the ice was geting stuck opened
with a small screwdriver push in tabs in upword movement to remove the face cover for the three botons of ice crushed ice and water .
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Coppell, TX
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice dispensor door would not open all the way and did not close
I used a mirror to locate the two small plastic tabs located on the underside of the ice dispenser light. I used a small flat blade screwdirver to push the plastic tabs forward to release the ice/water selector unit. I read about someone that did not see the tabs and ended up removing the inside of the freezer door, a two hour task! The ice and water control unit then slides out. remove the four rusty screws holding the dispensert and ice chute, the selenoid isthen easy to see.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Was this instruction helpful to you?
Thank you for voting!