Customer:
Estella from Paynes Creek, CA
Parts Used:
WR17X10703
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Ice deflector broke again as ice froze and dispenser was taxed causing it to break
Watched an online video that I had seen before that helped immensely step by step, I fixed before and now just lowered freezer setting so ice bucket doesn’t get as full and freeze the deflector and jam deflector, causing it to break.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Douglas from LAFAYETTE, LA
Parts Used:
WR02X11331
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Squeky Evaporator Fan
I made my wife fix it.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from SPANISH FORT, AL
Parts Used:
WR62X10055, WR17X11653, WR17X10706, WR02X10585
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
FROST IN FREEZER NO WATER
FOLLOW INSTRUCTIONS OF YOUR VIDEO
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Rockford, IL
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
heavy frost buildup in ice dispenser chute and door
After inspection of the new door recess assembly, I realized that I could use sidecutters (electronic assembly type) and 'clip' off the inward lock tabs of the old recess assembly and disengage it from the crank door arm without any further disassembly of the refrigerator door. It was easy to 'unhitch' the tang from the crank arm and wiggle it out through the external opening of the ice/water dispenser compartment. I reversed the process and inserted the new assembly through the external opening of the compartment. The new door recess assembly snapped into place on the crank arm and fit tightly against the ice chute opening, correcting the issue caused by aging distortion of the old rubber seal cup portion of the door recess assembly.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Harry from DURYEA, PA
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from CHARLESTON, SC
Parts Used:
WR29X10085
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
The left three tines bind and break off because they don't match the part removing the ice.
The right side of the three left three tines must be shaved about 1/8" to allow the ice remover blades to pass unimpeded.The part should be manufactured better.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frances from SPARTANBURG, SC
Parts Used:
WR12X10625, WR12X10625
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Drawer fronts on freezer needed replacing
New parts just snapped in place. Perfect fit.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Tucson, AZ
Parts Used:
WR17X10703
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Icemaker wouldnt dispense ice
Took the tray out, removed three screws, popped the front tray out, installed the deflector, and put it back together. Done in less than 15 minutes and my wife is ecstatic that our dispenser works again.
5 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from MC GRANN, PA
Parts Used:
WR17X10703
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Ice deflector was broken
took off the front panel, removed the auger and front piece, removed the pin and spring and installed them on to the new piece and then put everything back together
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JOHN from west End, NC
Parts Used:
WR01X10315
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
Stripped threads auger nut
removed ice bucket from frig. removed screws to dis assemble the box to get to the auger assembly,removed stripped nut replaced reassembled be care not to let the rest of the assembly fall from auger there are a lot of blades and spacers to try to get back to proper position.
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Robins, IA
Parts Used:
WR62X10055, WR17X11653, WR23X10783, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
Ice chute flapper would not close all the way
Following the advice of others on this site, I popped out the control panel by pushing up through the 2 outer-most holes on the under-side of the panel (the middle hole is unused). I installed the new solenoid exactly as shown in the PartSelect video. The new crank, spring, and flapper installed easily as well; I did apply a little grease to the hinge points on the crank to ensure no binding. I also installed a new microswitch. The wires are best removed from the old switch with a needlenose pliers. The old switch looked like it had some grease on the switch (where it makes contact with the cup lever) so I put some grease on the new switch as well. All-in-all, very easy and the frig works like new. It's nice to hear the flapper slam shut 4 seconds after dispensing ice.
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Coppell, TX
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice dispensor door would not open all the way and did not close
I used a mirror to locate the two small plastic tabs located on the underside of the ice dispenser light. I used a small flat blade screwdirver to push the plastic tabs forward to release the ice/water selector unit. I read about someone that did not see the tabs and ended up removing the inside of the freezer door, a two hour task! The ice and water control unit then slides out. remove the four rusty screws holding the dispensert and ice chute, the selenoid isthen easy to see.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Debra from Norfolk, VA
Parts Used:
WR71X10764
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Shelf broke
I just snapped in the new side to the shelf ...very simple and easy:-)
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from Shelton, CT
Parts Used:
WR82X10103
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
brand new ge refrigerator delivered with broken access cover. cost 6.95 so i repaced it myself.
removed 6 screws and repaced cover.
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Amy from Henderson, NY
Parts Used:
WR29X10085
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
ice maker was making no ice.
snapped in the new stripper arm where the defected one was.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PHE25YGXAFWW
106 - 120 of 571