Daniel from ZIONSVILLE, PA
Parts Used:
WR17X11168
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
water line (from the PS304374 Dual Inlet Water Valve) to the ice maker was craked and leaking
1. Removed the back panel of the fridge to get access to the inlet water valve.
2. Removed black poly water line from valve (pull back on white ring where line is attached and pull the line out)
3. Removed the inlet tube from top-back of fridge (where it goes into the ice make). use putty knife to get under the sticky white gasket beneath the black oval housing and pull the tube out form the back of the fridge.
4. Replace the water line with new part taking care to properly seat the line into the the bottom water valve and pushing the water tube into the hole for the ice maker.

Note: Be sure to take off the protective covering from the white - sticky grommet and push to adhere to metal on fridge.

to be safe - use a bit of clear silicone chaulking round the perimeter of the grommet and push to tighly bond the water inlet tube to the fridge.

The reason for this - is that if you do not get a good bond using the white - sticky gormmet alone - you may have the water tube inside the ice maker freeze up.

Also once the new water line is installed be sure to secure the line to the metal back of the fridge - so the line will not move. some fridges come with metal hose clamps to do this - otherwise use duct tape
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fillmore from Asheville, NC
Parts Used:
WR17X11440
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
water was squirting out a crack in water tank assembly.
This was a great opportunity to clean the bottom 3 shelves. I unplugged the frig.,disconnected both water lines, unscrewed water tank, pulled water lines out, put new tank in and pushed new water lines in and connected them, and plugged frig. back in. I grabbed my glass to get a drink and feeling proud but no water. I thought about this for a while and came to the conclusion that the freezer was set to 9 and the water had frozen in the value in the door. I dropped the temp. in the freezer from 9 to 3 and after about 2 days the water worked just fine. I emptied the ice because it was clumped into one big piece. I heard the ice maker going to town all day long. I called for ice later and the motor that dispenses the ice was humming and no ice was dropping. I thought about it and could not come up with the answer so I called tech. at GE and he was no help. So I solved one problem and now I have another that I don't have an answer to. My last attempt is to remove the motor housing to see if gears are jammed or something else.
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from MODESTO, CA
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers, Wrench (Adjustable)
Water line was leaking
The internal water line was leaking. I could not find any repair parts for my refrigerator but the GE 5/16 water line was the same size. I purchased 6' of tubing and two unions. Make sure the clean and square. If possible, make the cuts in a spot where you can use the pliers and wrench to tighten the union. I cut approximately 2' out of the existing line and replaced it with the same length of new line using the 2 unions, one on each end. Took about 5 minutes.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Centennial, AL
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light switch broke when I dropped a jar of jam on it.
The three bulbs would then remain on, so I loosened them to keep them off. I didn't know that the cooling system also would stop when the door was open, so for two days only the side freezer was operational. When I discovered that, I hot glued the switch button off, while I searched for a replacement part. The replacement part was an exact duplicate. A simple prying out of the old switch - using a screwdriver, and the reconnection of the two wires connectors to the new part, and clicking back in place ... done. Seriously, it took two minutes.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Lawerence, MI
Parts Used:
WR17X11505
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice would fall after removing glass.
I took the ice drawer out and turned it upside down. Then removed two philips screws holding the drawer front on. Then with a small straight edge screwdriver pry out the sides to release the locking tabs and remove the auger and crusher assembly. Then on the end of the auger remove the e-clip, slide the auger out and remove the broken part of the crusher dispenser and replace with new. Easier than it sounds. Parts Select was great to deal with. Had my parts in two days.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bert from SAN JOSE, CA
Parts Used:
WR60X30922
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
INTERMITENT LOUD NOISE FROM EVAPORATOR FAN IN FREEZER
The repair did not go exactly the way it was described in the YouTube video, but basically it was similar. After unplugging the power cord, emptying the freezer, removing the shelves and the ice reservoir, I removed the ice maker assembly by unscrewing a Philips head screw and unplugging the power connector. The connector had little retaining tabs on each side that I pried open with a straight blade screwdriver. Then the ice maker lifted right out. Next I removed one screw holding the auger motor assembly, unplugged the power connector, and lifted out the assembly. This where things got difficult. After flailing around a bit, I removed the panel on the back wall of the freezer below the evaporator fan assembly, exposing the evaporator coil. I saw that the fan assembly was attached with two screws at the top and two screws at the bottom. The top screws were easily removed, but when I removed the bottom screws, which were situated in very tight quarters, I DROPPED BOTH SCREWS DOWN BEHIND THE EVAPORATOR COIL. Be prepared with a magnetic nutdriver so this doesn't happen to you. I could not retrieve the lost screws, but fortunately it appears that the top screws hold the assembly securely enough. The assembly was loose, but it was still attached by a power cord that I could not disconnect. I removed the tracks on the side walls for the ice bucket, and then I could maneuver the fan motor assembly just enough that I could reach over the top of it, grab and pull off the old fan blade, and slide the new fan blade onto the shaft. Reassembly was straightforward, replacing each part (except two lost screws) in reverse order to disassembly. After getting everything put back in and plugging in the power cord, I was amazed at how quiet it ran.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Sugar Hill, GA
Parts Used:
WR12X10625
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
broken handle
Handle just snaps on.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
randall from coopersville, MI
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
refriderator not cooling consistetly
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alric H from Waynesville, NC
Parts Used:
WR17X11440
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
drinking water cooler leaked at the seam.
ordered replacement part with the understanding that tubing to the water valve could be easily removed. The tubes were carefully removed with some difficulty, and when the new tubes were inserted one leaked. The tube seat was not snug. Therefore a new water valve was purchased. The installation was successful within about 20 minutes. If I were to do the job again, both the water resevoir and valve would be ordered together.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Shepherdsville, KY
Parts Used:
WR17X11440
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Busted water tank
Removed the lower 2 drawers, lower front grill, rear lower compressor cover. Removed the 2 water lines from the quick connects and screws from the water tank. Pulled lines through the hole in the right rear of the refrigerator and removed tank. Then reversed steps to install new tank. The upper plastic tank cover has 2 buttons on top that are really screws with a plastic cap, these are easily removed with pliers.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gene from Springfield, IL
Parts Used:
WR17X11497
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
plastic parts came out of ice dispenser
Removed icemaker from freezer, remove covers allowing access to dispenser. In the next step I removed the auger and broken shield as one assembly. With assembly out of icemaker it was a simple task of taking the broken shield off of auger and putting the new one on. Reassemble in reverse order as removed.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from SCOTTSDALE, AZ
Parts Used:
WR55X10025
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mike from hatboro, PA
Parts Used:
WR62X10055, WR17X11653, WR23X10783, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Flapper is stuck open
There are three holes under the front panel in which you push a very small screwdriver in and the front panel comes off.In back of the panel is another panel with 4 screws .1 at each corner.Remove the 4 screws and that will come off exposing the working parts that need to be replaced.This is also a good time to clean anything you can get to in that area.It is very important to remember how everything came out.
6 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Indian Trail, NC
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
5/16" tubing to chilled water dispenser cracked
Cut out cracked tubing between valve and where tubing enters into refrigerator. Cut new tubing to length and attach to existing using union.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allan from Ponce Inlet, FL
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
replace solenoid on ice door
remove the front plate. use screwdriver to pry the cover off from the bottom of the cover, remove the wiring from the front cover.remove the 4 screws and pull out the shute. remove three screws from the solonide and replace . very easy fix. save yourself $100.00 labor.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!