Ice maker stopped making ice
I had made a dry run at the repair after watching the instructional film provided by part select and it seemed easy enough.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Schenectady, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
No Defrost - Top of freezer thawing
By the time this failure (failed defroster heating element) is evident (top of freezer starts thawing), the entire freezer coil is encased in a block of ice & frost is visble on the back freezer panel.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ronald from palmyra, VA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
freezer freezing and fresh food compartment not cooling
i unplugged the fridge, first i removed the racks, then unhooked the grounding clip. the i tool off two 1/4 nut screws holding the backplate. then i used my wifes hair dryer to thaw out the ice. after it thawed out i unscrewed the element bracket which is secured by two philips screw. after taking the screws off, its just unplug one end at a time and plug it to the new one to avoid confusion. then reverse install to put back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Grapevine, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
water dispenser/ice maker wouldn't work
Unplugged refrigerator and turned off water valve at wall. Removed the entire back, lower cardboard panel (turns out I didn't have to do this...could have just removed the screws from the right side and folded the cardboard along a perforated line designed for that purpose). Removed screw holding water control valve to back of refrigerator. Took new control valve, and slipped on adaptors for electrical connectors (in bag) to the two smaller of the four electrical prongs). Removed electrical sockets from old connector and placed them over appropriate prongs on new connector. Unscrewed the two old water out lines, cut the old fittings off and slipped the lines snugly into the new outlet valve (new valve had slip on connectors not requiring lines to be screwed in). Keep straight which line goes to which outlet port! Then removed water line going into old fitting and screwed it on to new valve inlet fitting (after removing black plastic protective cap). Turned wall water valve on, checked for leaks (none), and plugged refrigerator back in. Water restored to both icemaker and water dispenser!
By the way, the first valve came damaged, but one phone call and the people at Part Select promptly sent out a replacement which I had the very next day (and this was two days before Christmas!). Great job!
By the way, the first valve came damaged, but one phone call and the people at Part Select promptly sent out a replacement which I had the very next day (and this was two days before Christmas!). Great job!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Lake Quivira, KS
- Parts Used:
- WR71X10196
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Plastic Left Ice Bucket Shelf (slide) at the back broke around the pop rivet into the shelf .
At the front of the shelf there is a Phillips metal sheet metal screw that holds the front of the shelf in place. Its removal was fairly set straight forward but removing the pop rivet was awkward and took some time to drill out from the rear metal shelf. Once the rivet was out, it was easy finding a small screw that would hold the shelf in place since I didn't have any pop rivets that would fit sufficiently tight or long enough.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Longs, SC
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer building up Ice
This is such an easy fix!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kyoko from Bellevue, WA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
frost/ice buildup in icemaker chute in the freezer door
The only difficult part was not knowing which parts had to be removed to gain access to the flapper to replace it. It appeared as if the frame around the control panel would have to be removed as well as the door handle; we tried but were not able to remove the frame. It turned out that the panel just popped out with the frame in place. Once we had access to the flapper, it was easy to replace it. The repair fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Sarasota, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Open defrost heater
The most difficult part of the repair was the melting of the ice and preparation. I did change a single element heater for a dual element heater, which required a little manual flexing of the sub-frame, but it assembled with little issue. I was lucky, I did not have to splice the extended harness connection. Rerouting my existing gave sufficent length.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joey from Travelers Rest, SC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
The water valve was leaking
I Took the six screws off the back panel to get to underneath the refridgerator. took the 2 screws out of the bracket thast holds on the water valve took the 2 lines off and then put everything back
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- carol from Du Bois, IL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Defroster quit working. The freezer would frost up and not cool the fridge or freezer properly.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires.Threw away the old defroster. Put the new one in. I had to reroute the blue wire over to the right hand side and plugged it in.Put the back on. put the shelves in and I was done! We had this done just about 3 years ago and it cost us about $175. The cost of this repair was only $38.05 with shipping and all! What a great deal! Thanks so much PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daylyn from Houston, TX
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator not cooling // freezer running non-stop
Fortunately while my refirgerator was still under warrant I had this same problem and watched the repairman fix it. To confrm my suspicions I cleaned out the freezer compartment, removed the back panel (2 screws), and used a hair dryer to defrost it. I suggest plugging the drain hole or laying a towel in the bottom of the compartment to catch the run off or your drain pan could over low. Once defrosted I was able to verify that the element on the defrost heater was burnt. Since it was Sunday I re-assembled and cranked it back up until I could get the part. I did a goggle search on Monday, found the part instantly using only the model number from the refrigerator at PartsSelect.com. The part arrived Wednesday as promised, I repeated the process from Sunday, removed the defective part (2 screws & 2 plug in type wire connections) and she works like a charm now. I do think the manufacture of the part should consider a new design since this is the second one my unit has needed in less than 5 years. At only $27.50 ea. I should have purchased a spare to have for the next time!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Orient, OH
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frig AND freezer side not cooling
This is a repair INSIDE the freezer. Turned off unit.. Unplugged. Removed shelving on freezer side. Removed freezer draw rails (4 screws total.) Removed 2 screws that hold rear panel in place at rear of freezer side (this is inside the freezer). Carefully removed metal panel by pulling from the left (side that does not have shelving clips. As noted on this website and other users, the freezer coils were incased in ice. Thawed with a hair dryer (put towels in bottom of freezer-ice was pretty heavy in mine). When thawed, remove heater element by removing 2 screws that hold it to the aluminum bracket. Then remove wires on each end. Simply install the new emelment by attaching wires back on heater and screw new unit in place. (My original heating element was a single element-you could very easily see where the heating coil inside the glass tube had shorted out. My replacement heater was a 2 element unit. This did not pose any problem at all-installs in the same manner-good directions are provided.). Replace all parts in reverse order. It's that simple. Saved probably $150. This site is wonderful! Fast shipping and the users install tips/notes are fantastic!! Will shop here again if I have to (have a Maytag washer that isn't draining and going into spin-bet the fix is on here somewhere!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- frank from Pittston, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Appeared to be too large at first...
At first the part appeared to be too large because of the change from one heater to two heaters in the replacement part. It was necessary to push a copper refrigerant line back out ot the way about an inch or so before the part would fit properly. This might take a little courage from the do-it-yourselfer, but it moved easily and seems no worse for the move. Currently the fridge is working well(two weeks) with no buildup of any frost on freezer panel as previouly noted. Overall experience was just fine. Makes d-i-y guy look good!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from Deerfield Beach, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Coils at back of freezer icing over
After reading posts on this website, I determined I needed to replace the defrost heater. Removed heater to take a closer look and after testing with a voltmeter determined it needed replacing. Ordered part online and could not believe how quickly it arrived. Blue wire that travels down the left side of the freezer coils had some damage on the end of the plastic connector so was pleased to find that I was able to splice the extension wire provided in the defrost heater kit onto the blue wire and dispose of the damaged end. It's been about 10 days and I do believe my problem has been solved!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Medford, OR
- Parts Used:
- WR13X10020
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Emptied refrigerator door shelves. Supported door with 4x4 blocks.removed old door hinge and replaced with new.
Emptied refrigerator door shelves. Supported door with 4x4 blocks. Removed old door hinge and replaced with new door hinge and cams. Pleased with end result and dealing with PartSelect.
Was this instruction helpful to you?
Thank you for voting!