- Customer:
- Catherine from SEATTLE, WA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Ooltewah, TN
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator and freezer started loosing its cool
Removed cover exposing defrost heater. Defrosted the cooling system. Removed screws holding defroster, replaced old with new, by way of two quick connect eletrical clips. replaced cover. Pretty easy once I figured our that it was the defroster and not the timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pap's Sport Shop from Webster Springs, WV
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Defroster unit went out
First let me remind you my husband is disabled so it was up to me to do the repair. I'm 70 yrs old. I first removed everything from freezer and then removed the back cover removimg 4 screws,then i removed the old defrost unit which held 2 screws replaced with the new one then i had to put cover back in place..then put everything back in freezer and so far its working...Only time will tell.But the part was so reasonable that if if i have to i will get another..but not for a while i'm hoping,
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Grand Forks, ND
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Water valve cracked
Pulled out the fridge - unpluged. Water supply was already closed.
Then took off the cardboard cover in the back. Used a nut driver to remove 1 screw. Disconnected water lines and elec. connects.
Water lines slid into quick connects - connected electrical and mounted. Opened water suply needle valve.
Pluged in fridge did a quick test for leaks. Done in 5min.
Then took off the cardboard cover in the back. Used a nut driver to remove 1 screw. Disconnected water lines and elec. connects.
Water lines slid into quick connects - connected electrical and mounted. Opened water suply needle valve.
Pluged in fridge did a quick test for leaks. Done in 5min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Grapevine, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
water dispenser/ice maker wouldn't work
Unplugged refrigerator and turned off water valve at wall. Removed the entire back, lower cardboard panel (turns out I didn't have to do this...could have just removed the screws from the right side and folded the cardboard along a perforated line designed for that purpose). Removed screw holding water control valve to back of refrigerator. Took new control valve, and slipped on adaptors for electrical connectors (in bag) to the two smaller of the four electrical prongs). Removed electrical sockets from old connector and placed them over appropriate prongs on new connector. Unscrewed the two old water out lines, cut the old fittings off and slipped the lines snugly into the new outlet valve (new valve had slip on connectors not requiring lines to be screwed in). Keep straight which line goes to which outlet port! Then removed water line going into old fitting and screwed it on to new valve inlet fitting (after removing black plastic protective cap). Turned wall water valve on, checked for leaks (none), and plugged refrigerator back in. Water restored to both icemaker and water dispenser!
By the way, the first valve came damaged, but one phone call and the people at Part Select promptly sent out a replacement which I had the very next day (and this was two days before Christmas!). Great job!
By the way, the first valve came damaged, but one phone call and the people at Part Select promptly sent out a replacement which I had the very next day (and this was two days before Christmas!). Great job!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Wyckoff, NJ
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker stopped making ice
I had made a dry run at the repair after watching the instructional film provided by part select and it seemed easy enough.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marc from Hollywood, FL
- Parts Used:
- WR71X2373
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Needed a new door module
Fit perfectly, took 2 seconds to install.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- josh from springfield, OR
- Parts Used:
- WR72X10010, WR72X10009, WR72X10008, WR72X10007
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
drawer rails broken
installed 3 of 4 shipped parts. ended up with 2 upper right hand slide rails, even though ones package said upper left.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roger from Colleyville, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
No water through door dispenser
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Amazing.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sandy from Greenwood, SC
- Parts Used:
- WR72X10010, WR72X10009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
the slide rail on the top drawer broke in half
I took the glass plate off the top of the drawer, then removed the draw. I then removed the two screws holding the slide rail. I put the new slide rail in place, put the screws back in it, slide the drawer back in place and replaced the glass top. nothing to it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tony from Conover, NC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench set
Water leak from the Water Valve.
I received my parts in 2 days, that is fast. It took me less than 15 minutes to install the unit. Now I've got ice and water from my refrigerator. Instead of taking expensive warranties, I would rather order parts from your company and do it myself on all my appliances.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Hills, IA
- Parts Used:
- WR62X23154
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Crushed Ice Only
Let me start by saying, I usually hire something like this out but figured I would give it a try. The install was fairly straight forward, however it would’ve been nice if the instructions would have been more useful. Instructing me to remove one screw to release the auger and solenoid enclosure wouldve been nice. There were 3 other screws that I didn’t need to remove and they were the ones holding the auger in place, which made assembling that much more difficult. Once to enclosure was removed, and the solenoid was exposed, it was a seemless process. I would however, recommend paying attention to or taking a picture of the connections on the solenoid. I was lucky to remember or got lucky. Regardless, I was able to complete the project successfully. If I had to do it again, I believe it can be done in 30 minutes or less.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Sarasota, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Open defrost heater
The most difficult part of the repair was the melting of the ice and preparation. I did change a single element heater for a dual element heater, which required a little manual flexing of the sub-frame, but it assembled with little issue. I was lucky, I did not have to splice the extended harness connection. Rerouting my existing gave sufficent length.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kyoko from Bellevue, WA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
frost/ice buildup in icemaker chute in the freezer door
The only difficult part was not knowing which parts had to be removed to gain access to the flapper to replace it. It appeared as if the frame around the control panel would have to be removed as well as the door handle; we tried but were not able to remove the frame. It turned out that the panel just popped out with the frame in place. Once we had access to the flapper, it was easy to replace it. The repair fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Middleville, MI
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
refrigerator not cold
I called the repair tech who obviously did not want to come out, thank god. He told me to remove the back panel of the freezer and also check fan on back side. Told him there was alot of ice on freezer condenser and he advised that defrost heater was probably shot, and referred me to partselect.com. I unplugged the frig/freezerer, and removed the heater and saw it was blackened and cooked. I used a hairdryer to thaw the condenser, and the new part arrived the next day. I reattached the 2 plugs, 2 screws, and put the back panel of the freezer back on. I plugged the appliance back in, checked it 6 hours later and the frig is cold again. It was a VERY easy repair and took less than 30 minutes from start to finish. I was quoted between $40-$78 for the part at 3 different places in the phone book, which would have also required a 45 minute drive. I got it here for $38 including shipping and it arrived in 24 hours !
With the "blow-up view" appliance feature on this web-site, and simply being guided to the correct part by entering the model number, it was a very easy ordering process and repair.
With the "blow-up view" appliance feature on this web-site, and simply being guided to the correct part by entering the model number, it was a very easy ordering process and repair.
Was this instruction helpful to you?
Thank you for voting!