Customer:
D from ZELLWOOD, FL
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
richard from cleburne, TX
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer freezing up
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
16 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lowell H from Gilbert, AZ
Parts Used:
WR2X8702
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Water and Ice acuator had a hole in it. Need to be replaced.
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cristina from Los Angeles, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from DOWS, IA
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Freezer Cold Refrigerator warm
The defrost heater failed. The coils frosted completely over so no airflow to the fridge. Step 1. Empty the freezer. Ice maker and top shelf can stay. Remove power, pull plug or open breaker. Step 2. Remove shelves and bottom food drawer. Step 3. Remove bottom food drawer rails. 2 phillips screws on each side. Step 4. Remove back panel, 2 screws at the top. Work panel out. Note there may be a green ground wire hook on it at the top. This will expose the heater and the cooling coils. The heater is at the bottom of the cooling coils and is the width of the coils. Step 5. There will be 2 wires, one on each end, and two phillips screws holding it in. Wires pull straight out. Note which way the heater is installed and remove the 2 screws. Step 6. Assemble in reverse order. Be very careful with the heater. It is in a glass tube and is very easy to break.
13 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
debbie from chino hills, CA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
icemaker developed a leak and froze over
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
18 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ron from Lone Tree, CO
Parts Used:
WR51X10029
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Make sure you put everything back in the order you took them out.
I had to back-track acouple of times because I put the shelf brackets back in before I had the back panel in.It was also alittle tight getting the thermostat snapped back on the refrigerant line because it is a tight space and I have big hands.For a first timer who has had minimal experiance it wasn't too tough.
21 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
PERRY from VANDERBILT, MI
Parts Used:
WR60X187
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Wrench set
Noisey Motor, Bearings Out, Dying
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning while your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leo from TWIN FALLS, ID
Parts Used:
40A15
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
22 of 43 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from Phoenix, AZ
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice maker ot making ice
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
18 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Janet from Weston, FL
Parts Used:
WR57X10022
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Wrench set
Steady drip of water out of the water valve
I unplugged the refrigerator and removed the black fiberboard panel at the back of the unit. I turned off the water at the wall and disconnected the copper water line from the unit.

One bolt holds the valve assembly in place. Once the bolt is removed you simply pull the unit out of the refrigerator. I took the time to mark all electrical connections and water lines (1, 2, 3, etc.) and wrote the corresponding numbers on the new valve unit. I unplugged the electrical connections and removed all water lines by gently squeezing them with the pliers and pulling them out of the old valve.

After everything was disconnected I connected the new valve. The numbering system made it easy to know exactly which plug/line went where and it was reconnected in less than 2 mins. I slid the unit back, replaced the single bolt holding the unit, reconnected the main copper water line, turned it on, placed the fiberboard back in place and was done.

We had an estimate from a refrigerator repairman of $275 to change this valve, parts & labor. We thought it was ridiculously high and decided to attempt the repair ourselves. Best decision we ever made and saved a fortune.

This is definitely an easy fix. Go for it!
14 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MILTON from MARIETTA, GA
Parts Used:
WR57X10023
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set, Wrench set
water leak from valve
The hardest part was moving the side-by-side refigerator out from the wall. After accessing the back of the unit ,it was a matter of removing a few screws to remove the back plate. The valve was attached with one screw that held it to the unit. After disconnecting the electrical and water lines the valve was out. Replaced the new valve in reverse order. Everything works great.
23 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Virginia Beach, VA
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper was stuck open. Old and warped.
Replaced flapper
16 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Midland, MI
Parts Used:
WR57X10023
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Wrench set
Water was leaking from rear of refirgerator
Unplugged refrigerator.
Disconnected inlet water line.
Disconnected outlet from leaking valve.
Unplugged electrical connections.
Reversed with the new part.

Plugged it back and there were no more leaks.
18 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Coppell, TX
Parts Used:
WR57X10023
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Water on door quit working
After changing the water filter to eliminate that, I did some research and determined it was probably a water valve. As this unit has a primary and secondary, and the secondary feeds the door (after receiving water from the primary) I mistakenly replaced the secondary. It was the primary water valve which was trickling enough water to keep the icemaker happy but not enough to drive the water on the door. In the future, I will do a test with a spare piece of water line which I ultimately did to figure this one out.
16 of 28 people found this instruction helpful.