- Customer:
- John from Chapel Hill, NC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Leaking valve
The valve was leaking from the core and not the in/out tubes. The valve is easy to get to and very easy to replace. When replacing the water in/outs you cut them off the old valve and then slip them on the new valve. 5 to 10 minute job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Craig from Land O Lakes, FL
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Water flow was too low
Turn off water valve to the refigerator and disconnect line.
Remove the cardboard backing and insulation.
Remove old valve and cut lines close to the valve.
Trim plastic on new valve as needed to fit (generic valve).
Insert water lines into new valve.
Install new valve.
Connect water line and open valve.
Replace cardboard backing and insulation.
Remove the cardboard backing and insulation.
Remove old valve and cut lines close to the valve.
Trim plastic on new valve as needed to fit (generic valve).
Insert water lines into new valve.
Install new valve.
Connect water line and open valve.
Replace cardboard backing and insulation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Somerset, KY
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set, Wrench (Adjustable)
water wouldn't shut off
replaced solenoid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Al from River Edge, NJ
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker discharge was slow and jammed with ice and frost. The cause was a distorted flapper that did not seal properly, admitting warm air into the dispenser chamber.
Excellent video was available on the Parts Select website. It was simple. The selector panel pulled out by hand from the bottom. The subpanel was removed with the four screws. The flapper snapped out of the holder with two clips. The new one was inserted in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JACOB from COLLEGEVILLE, PA
- Parts Used:
- WR62X23154
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Only crushed ice. No cubed.
Found a step by step video on YouTube made replacement very easy. Cubed ice is back. Time for a cocktail to celebrate!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Poquoson, VA
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
My icemaker was leaking down the back wall of the freezer (side-by-side unit) building a huge ice flow that grew into the path of the circulation fan.
After turning the water off, I removed the two screws holding the cover on the lower back of the freezer. I disconnected the copper water supply line from the valve. I then removed the screw holding the valve in place and removed it from the freezer. I removed the two wires from the valve and placed them on the new valve (after inserting the clip inserts to match the new size tabs).I pulled the two plastic water lines out of the valve and inserted them into the new valve. I put the new valve in place and replaced the screw. Total time less than 15 minutes. Much easier to fix, than to identify the problem. The collective wisdom of the internet strikes again! Thanks to all.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Groesbeck, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
water over filling ice tray and leaking into ice tray and freezing
Followed the directions on the web site and did everything that was instructed to do and had no problems with installing the new dual water Valve. Has been in now for a week and no more over filling or freezing water in the storage box. Lots of clean ice, now!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ROBERT from STOW, OH
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench set
no ice
Removed cardboard cover from back of refrigerator with nutdriver. Removed old pump and reconnected water lines and electrical. reinstalled pump.It did take about 5-10 minutes for the pump to refill ice tray.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Old Bethpage, NY
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Leaky valve
Removed three screws, water input line, two water output lines. The new valve had push on fittings instead of screw on, so had to cut the old fittings off. Connecte input and output lines Replaced three screws holding valve in place. Turned water back on. Finished.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Port Monmouth, NJ
- Parts Used:
- WR57X10051, WR17X4358
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
dispenser reservior was leaking water outlet vale also developed a leak
shut the water supply to the refridgerator unscrewed valve mount removed removed valve supply line with half inch wrench loosened and removed plastic nuts on outlet by hand unplugged both valve actuator cables. loosened two phillips screws from reservior removed inlet and outlet hoses replaced with new parts very simple repair
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Johnathan from Gilbert, AZ
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Ice maker overflowing. Valve stuck open
The valve I got was slightly bent up. I spent the first 10 minutes or so bending it back with my muscles. once that was done, I took off the backing of the fridge with the screwdriver, undid the single bolt holding the valve on, and unplugged it all (fridge was already unplugged). Just like everyone says, the tubing connecter is different, so I took off the old compression fittings, and pushed the tubes in. THen I hooked up the wiring... I realized that that the wiring adapter was needed but there wasn't enough room for it as is.. so I have to bend the tabs so the wiring would angle down. Everything has worked perfect since... I got Ice and no leaks! woo hoo!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from HOSCHTON, GA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frost collected in the ice dispenser shute clogging it
Replace the flapper and this solved it. The video provided was excellent and allowed me to do this repair myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- kathleen from red oak, TX
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Wrench set
leaking water valve
I used a screwdriver to remove, then replace, the screw that holds in the valve. I used pliers to pull the refer water line out of the old valve. I just used my hands to reinstall the line. I used and open box wrench to remove and reattach the main water line. Nothing blocked access to the valve and it was very easy to remove the old one and install the new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clayton from TUCSON, AZ
- Parts Used:
- WR62X23154
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Ice crusher did not work, Ice would plug in tub chute on discharge end.
Pulled ice tub, removed auger rotation motor and solenoid housing, removed solenoid and replaced with new one and reinstalled. Checked solenoid was working by holding freezer door open and closing switch to door an activating ice switch-- solenoid picked up. Put ice tub with auger back into freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jabe from Little Torch Key, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
In-Door Dispenser Didn't Work And Leaked Water
1. Use skewer to press plastic tabs under control panel, 2. Remove control panel and unplug solenoid, 3. Unscrew dispenser assembly and solenoid screws, 4. Press in tabs on lamp and remove assembly - unplug, 5. Replace lamp assembly, 6. Replace solenoid assembly and fasten screws, 7. Replace flapper. 8. Replace other parts in reverse order.
Was this instruction helpful to you?
Thank you for voting!