Customer:
John from Windham, NH
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers, Socket set
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
23 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from The Villages, FL
Parts Used:
WR17X11168
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Tube feeding ice maker leaking.
Moved refrigerator out from wall. On the back of the refrigerator at the bottom there is a metal plate. Removed this plate with a socket wrench to expose where the end of the tube pluged in. The grommet securing the tube, white on my unit, had to be pushed up to release the old tube. I pushed the new tube into where the old one was and it self secured the tube. The other end of the grommet I pushed through the hole feeding the ice maker,first pushing out the broked part with a screwdriver,and securing that end with the attached sticky tape already attached to the grommet. I cleaned the area around the hole with alcohol before attaching the grommet.Replaced metal plate and done. No leaks.
23 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carlos from Whittier, CA
Parts Used:
WR17X11168
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
water leaking from grommet tube assembly at back of fridge
After thawing out freezer pushed water supply tube out from inside freezer diconneted the supply line from the valve assembly by pushing in the bushing with my finger and inserting the new line. Sadly that wasn't the problem!For anyone with the same symptoms of ice building up on your ice maker, to the point where it clogged the water supply line and started leaking from the grommet assembly. The problem is the valve not closing when the ice maker does not need any water. so I ordered a new valve and hopefully that will fix my problem.
22 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Craig from Soldotna, AK
Parts Used:
WR07X10057
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Compressor does not run
The first component I suspect is the relay mounted near the compressor. I installed the replacement relay and still nothing. I then removed the control board, inspected it for burnt circuit paths or components. I noticed the c.b. relay for the compressor's lead had burned away the solder and there was no longer a viable connection. Not sure why this happened but my next step is to a) reestablish a solder connection. If this fails then b) replace the control board.
26 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Luci from Richvale, CA
Parts Used:
WR71X10973, WR71X10979, WR71X10764
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
We Needed more food storage space.
We noticed that there was door area that could be used - so I went hunting for more shlves - Thank Yo for having them in stock....This is used for a Care Home for Multi-Handicapped ladies and their staff....Much appreciated!
24 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from Abington, MA
Parts Used:
WR60X10205, WR60X10185
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
The evap fan burnt out again (after 2 yrs)
I had to remove the contents of the freezer, and remove the fan covers ( 2 screws) and the back of the freezer. I pulled out the evap motor assembly, removed the motor from that and re-installed the new motor into the assembly, (2 screws). Installed the evap assembly back into the freezer, ( another 2 screws), making sure to plug the motor into the wire harness and keeping the wires away from the fan blades. Then installed the back of the freezer (2 screws...again) and put on the 2 plastic pieces that completes the freezer assembly. I plugged the refrigerator back in and heard the fan start and knew everything was going to work fine
21 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Glendale, AZ
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
21 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
justin from brownsville, OH
Parts Used:
WR49X10091
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
evertthing in frige was freezing
went online to an appliance repair site and found out that this model has problems with the damper malfunctioning. went to partselect and ordered what I needed and it arrived in two days. to replace the damper you just remove the light at the top of the frige and the cover around it . the damper assembly only has 2 screws and is easy to remove.
19 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tracy from Yuba City, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Jacksonville, FL
Parts Used:
WR11X10010
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer door lever broke
Unscrew the two mounting screws for the plastic vent plate on the bottom of the SS unit and take the remove the vent. Next, slide the end of the lever through the square hole in the bottom bracket and attach the hook end of the lever to one end of the lever spring. Pull on the other end of the lever spring and slip it over the spring mount finger that is a part of the bottom bracket frame. Finally,reattach the plastic vent plate with the 2 mounting screws. Total repair time was less than 15 minutes.
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mohammad from fremont, CA
Parts Used:
WR57X10023
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
The water was leaking from below the refrigerator, and a big puddle was being formed.
First I removed the screws, and the covering at the bottom rear of the GE Fridge. I then removed the existing water valve which was the source of water leak, it was all corroded with the leak at the valve joints, so I knew the water valve needed to be replaced. The water valve I received from PartSelect fitted in perfectly, once I had removed the old valve. All I needed was couple of screw drivers for the replacement. I would like to thank PartSelect for making this easy and saving me lots of money & time by not going for outside professional help.
16 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Meridian, MS
Parts Used:
WR17X11168
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
Icemaker supply hose leaking at freezer entrance
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Herbert from Sunriver, OR
Parts Used:
WR55X10942C, WR49X10091
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Frozen water filter and food in fresh food side
Initial diagnosis indicated faulty cold air damper, so first action was to remove the light assembly and then the plastic housing that contains the FF fan and damper. The two hidden screws at base of housing required removal of lower decorative plastic duct that turned to be held by snap in-tabs at top and slide away fastener at bottom. The damper housing is held to the roof of the FF chamber by two screws that were taken out to remove the light assembly.

When the plastic housing is pulled towards the front of the refrigerator, the multi-pin wire connector can be disconnected and the damper assembly easily removed.

Installation required need of a thin plate to seat a sponge rubber seal without damage, so I used a thin metal kitchen spatula. Nothing unexpected was encountered in reversing the disassembly process.

Although the new damper corrected the excessive cold situation, the temperature max-min span remained in excess of 15 degrees F, so the control panel was swapped in the small covered cavity located in the outside back of the refrigerator. A 1/4" nut driver and needle nose pliers were all the tools necessary for this operation.

Together the two replacement components have solved the frozen food problem and the over night max-min FF span is now 5 degrees or less.
16 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
richard from cleburne, TX
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer freezing up
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
16 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cristina from Los Angeles, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours