Models > PDS22MBRBWW > Instructions

PDS22MBRBWW General Electric Refrigerator - Instructions

Jump to:

All Instructions for the PDS22MBRBWW
91 - 105 of 304
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
WILLIAM from YUMA, AZ
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
Frige stopped cooling completely
i Removed back panels and then I removed the faulty circuit board. Installed new circuit board and presto everything worked. I can't believe how easy it was but on the other hand I couldn't believe a refrigerator had such a sophisticated part..
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Pacheco, CA
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
The evaporator fan in the freezer would slow down and speed up for a long period of time before eventually shutting down at the end of a cooling cycle.
Tom Paone at quality@applianceeducator.com. was very helpful at recommending that a solution to my problem was to replace the ASM Main Domestic Motherboard. I ordered and received the board in two days from PartSelect. After unplugging the refrigerator I used a nut driver to remove the three screws that held the motherboard cover in place and then disconnected all of the connections to the board. Next, using a pair of needle nose pliers, I gently squeezed on the white plastic anchor retainers that fastened the motherboard to the refrigerator. While doing this at each anchor I gently pulled on the motherboard until it was separated from the retainer anchor post. There were four retainers total. I removed the old board and in the reverse order installed the new board. All of the connectors were easy to match to the new board because the wiring connectors coming out of the back of the refrigerator were only long enough to hook to the correct connectors on the circuit board. There was an extra connector that I didn't use on the new board and also the connection for the ground wire used a ring connector instead of a spade connector. To remedy this I simply used the ground wire assembly from my old board. I also took the time to remove the lower cover on my refrigerator and cleaned the condensing coil with a vacuum cleaner. The total time to replace the motherboard and clean the condensing coil was about 20 minutes from start to finish. This repair solved the problem with my evaporator fan. A big thanks to Tom Paone at quality@applianceeducator.com. for helping diagnosis my problem and suggesting the correct replacement part. I saved between $100.00 to $150.00 not having to call out an appliance repair person to fix my refrigerator.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kyle from Norwalk, IA
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
whining noise coming from GE refrigerator
It was a very simple installation after reading about everyone else having the same "noise" problem with their GE side by side refrigerator.

I simply; pulled the refrigerator out, turned off the power, took off the 3 screws to remove the plate, unhooked the 5 or so connections with my hands, put the new part in, hooked the connections up, put the plate back on, plugged the refrigerator back in, and slid in back into place. It took around 10 minutes to do, very simple.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edsel from Haynesville, LA
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
replace main control board
Unplug the refrigerator from the wall plug and take the plate off of the circuit board in the back of the refrigerator. Remove the screws holding the board in place. Remove the board by pinching the little white pins holding the board inplace. Disconnect the wires from the circuit board and install the new board in its place. Notice the wire prongs so that they are connected the same as they were on the previous board. Replace the screws that hold the cover. Plug it in. If it does not turn on, remove the plug from the wall and re insert it. The new board has to reset itself.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ron from Bonney Lake, WA
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
would not regulate temp.
replaced main board.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rodney from Dallas, TX
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Relay on motherboard was clicking-Quit cooling
Followed the partselect video on how to replace motherboard and the video described the exact replacement procedure.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Catherine from SEATTLE, WA
Parts Used:
40A15
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.

No tools needed, the cap is just held in place with pressure from the wire.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from Cheyenne, WY
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Periodic and intermittent "clicking," during which the lights on the temp control unit would go out. When clicking stopped and lights returned, temp control unit was not accepting adjustments in temp
Had friend assist in pulling fridge out from it's area so that I could access back. Unplugged unit. For the bottom freezer units (mine) the compartment containing the main control board is middle of the fridge and on the left. Took off the protective metal plate and then followed the video demonstrating the repair. One other discrepancy between the video and the instructions that came with the new main control board, is that the instructions suggested locating and cutting some other green wire to the compressor unit. I chose not to do that, as the unit was otherwise working fine as is prior to my main control board going south.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from ROSEMOUNT, MN
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Johnnie from KANSAS CITY, MO
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
The Ground wires wasn't in same location on board
i had to improvise And relocate ground wire to get a proper ground .. That's all , the video was a GREAT HELP...
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cecilia from NATALIA, TX
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer would not freeze and fridge would not cool after power outages
I used a volt/ohm meter and checked for power to compressor and start run relays, diagnosis- was remove and replace motherboard
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from COLUMBIA, SC
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carl from BELLVILLE, TX
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Unit was dead
Removed and replaced control board
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jaime from SYLMAR, CA
Parts Used:
WR55X10942
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set
No Cooling on either freezer or refrigerator
Everything seemed to be working right, but no cooling, so I tried turning on and off the switch that turns the light on 5 times within two seconds, refrigerator did not shot. so I removed the main board and I notice a short had taken place on one of the relay legs. I ordered the main board and replaced it. The main board is on the back of the freezer covered with a sheet metal panel about 8"x8" and is secured with hex sheet metal screws. Everything is working now. Please make sure to unplug the unit from power before removing the main board.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roscoe G from ROCHESTER, NY
Parts Used:
40A15
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!