PSS25MCMAWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- EDWARD from INDIAN WELLS, CA
- Parts Used:
- WR23X31507
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Fresh food section lights were all out, but the bulbs tested good elsewhere.
I popped the switch out using the blade of a small screwdriver and noticed that it connected with two wires via a slide on connector for each one. I noted the info on the old switch to identify which wire went to which terminal. I held each wire with a pair of pliers while I pulled the wire connector off the terminal on the old switch. I connected the two wires to the correct terminals on the new swith, and popped the switch back into the door frame. Easy, easy, easy and saved the $40 service call + parts cost!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Boca Raton, FL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Ice Dispenser not working
As it turned out much of the electronics is driven by 13.5 volts off the Main Control Board. The Ice Dispenser caused the problem because it over currented the depleted board power. You could hear a clicking noise from the board which was the main relay short cycling and not staying energized. While waiting for the replacement board I unpluged the condenser fan which is a DC motor and uses the Board power. In place of that fan I use a small table top fan to keep the condenser cool. As it turned out I only needed it for 3 days because Parts Select did a super quick job of delivering the new board. Thanks for the super service!!!!!! Removal of the board only required unpluging the electrical connections squezing the retaining board pins with pliers and pulling the board out, pushing on the new board and connecting the electrical plugs. If the board locks like mine did, just unplug the main board power plug, let the memory clear and replug the power plug. The unit should then start and run with no problems.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barbara from BELLEVUE, WA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- Less than 15 mins
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jo Anne from Walnut, CA
- Parts Used:
- WR32X10156
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
glass panel cover/glass cracked
First, I removed the top drawer blocking the area where I needed to put the glass panel cover. Then, I removed the drawer along with the glass panel holder to which I needed to install the glass. I installed the glass to the panel holder without difficulties (although the glass cover was expensive :() and reinstall the drawers back to their proper place. This repair was actually a no-brainer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Powell, TN
- Parts Used:
- WR71X10582
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
replace split shelf with solid one
The slideout shelf "assembly" comes without the
keeper tab, and as such is incomplete. You have to order it separately or rob it from the old one. If the old one is broken or you break it trying to get it out of the old one you're out of luck unless you ordered
the tab also. Other than that it's a no-brainer.
keeper tab, and as such is incomplete. You have to order it separately or rob it from the old one. If the old one is broken or you break it trying to get it out of the old one you're out of luck unless you ordered
the tab also. Other than that it's a no-brainer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Greg from Eden prairie, MN
- Parts Used:
- WR57X10023
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Water Leaking from behind refrigerator
Turn off water to the refrigerator and unplug from wall outlet remove the defective inlet valve replace with new inlet valve. Now is a great to clean use a air compressor and vacuum and your old crusty frige will be good as new ! Special thanks to Parts Select fast shipping and original ge parts!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- chris from GROVE CITY, OH
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
The eavporator coils were completely frozen which prevented fridge-freezer air circulation
1. Removed all food, shelves, and ice bin from freezer compartment.
2. Removed freezer light hood and unscrewed freezer bulb.
3. Removed rear evaporator cover panel (2 Phillip’s screws, 2 hex screws).
4. Melted ice on coils with hair blow dryer (needed bath towels to collected water).
5. Removed old defrost heater (2 Phillips screws, 2 plug-ins).
6. New heater connected without any adjustments.
7. Replaced evaporator cover ice bin, shelves and food.
2. Removed freezer light hood and unscrewed freezer bulb.
3. Removed rear evaporator cover panel (2 Phillip’s screws, 2 hex screws).
4. Melted ice on coils with hair blow dryer (needed bath towels to collected water).
5. Removed old defrost heater (2 Phillips screws, 2 plug-ins).
6. New heater connected without any adjustments.
7. Replaced evaporator cover ice bin, shelves and food.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JAMES from HENDERSON, CO
- Parts Used:
- WR50X10068, WR51X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench set
Evaporate coils freezing up-refrigerator/freezer warm
Level of difficulty, as far a mechanical skill goes is relatively easy; however, everything in the interior of the freezer (including icemaker) must be removed to get to the defrost thermostat. The defrost heater only needs the racks and back panel removed. It probably took about 45 minutes with a heat gun to melt the ice off of the coils so that I could work on it-need lots of towels/rags to pick up the water.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Cortlandt Manor, NY
- Parts Used:
- WR57X10024
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
No water/no ice
The first sign of trouble was when the water dispenser would continue to come out after you let up on the button. Then water and ice stopped. Changed the secondary inlet value and the main water valve, as well as a 1/4" water line running to the freezer (it was cracked). Water is working. Ice maker is working better than ever. New life for an aged refrige.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- M &M Aviation from ESCANABA, MI
- Parts Used:
- WR55X10025, WR02X10668, WR02X10647
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator side freezing food
Replaced both temp sensors worked good for 2 days then began freezing food. Looked into it further on line. Found small motorized door broken that controls the cold air from the freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Tampa, FL
- Parts Used:
- WR57X10023
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
leaked
replaced water valve for 50 dollars, saved about 200 dollars by doing it myself
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- inessa from manalapan, NJ
- Parts Used:
- WR23X21444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
frezer door light switch broke (I have 2 boys :)
The repaire guy came in tooke it out and told me it is goin to coast $20 for the part and $50 for the labor..... So I looked, It was soooo eeezzz ALL you have to do is get the switch out( with help of my butter knife :) it plugs in to a little outlet on the wire (on the botom side) so take out the old one and plug in the new one wich I got for $8 + $6 shipping = $15 THANK YOU PART SELECT for saving me $55 Im a 36 y/o stayathome mom and Ihave never don this before, Im very proud of my self. well... it was very easy!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Woodland, CA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Water dispenser wouldn't work and refrigerator made an almost ghost like howling sound. Replacement main board fixed the noise. I purchased the replacement board for the ice and water (front of the refer) but haven't installed it yet.
I watched the on live video. Piece of cake!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- josephine from rochester, NY
- Parts Used:
- WR50X10068, WR55X10025, WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
coil would freeze up about every 2-3 weeks
took back panel off in freezer.unpluged unit then cut wire to sensor tie in new one wire nut them up and taped.on the heater strip took off two screws and unpluged two wires put the new in same way as taking old one off.I am pleased that the parts from part select came as fast as they did I would for sure buy from them again and prices were very fair.Thank you very much for your service.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frederick K from Kingston, TN
- Parts Used:
- WR49X10091
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
GE Profile Arctica food locker was below freezing
The trouble shooting information on the web site indicated that the damper door within the climate control unit may be broken. This was easily confirmed and the replacement of the climate control unit immediately returned the food locker temperatures to the digital electronic thermostat settings. The part has an improved ventilation gasket interface between the food locker and freezer. The unit works perfectly again, and the food locker temperature is exactly what the thermostat setting is.
Was this instruction helpful to you?
Thank you for voting!