Customer:
Gary from North Salt Lake, UT
Parts Used:
WR17X22070, WR57X33326
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Getting ice but not water from the dispenser
On the web site I explained the problem and the solution was immediate. I went to the installation video and was instructed how to install the double outlet valve. It took about 10 minutes to take out the old part and install the new one. I didn't have water immediately so I viewed comments by others and learned that I may have a frozen line in the door. I tried thawing out the line and in about 3 hours and I had water. I figure I saved about $200.00 by doing it myself. Thank you partselect.com
75 of 98 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ray from Bensalem, PA
Parts Used:
WR60X10209
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
fan not running
Removed rear and front grills,brushed and vacuumed area- probably caused the fan motor to fail- unplugged fan, removed fan,motor,and shroud in 1 piece, carefully slipped fan off motor shaft, unscrewed shroud and motor. assembled in reverse order. Frige is in tight area, .I'll now roll it out and clean often
74 of 102 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Romeo, MI
Parts Used:
WR60X10185
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
The evaporator fan motor stopped running, freezer was warmer than normal
First ,I placed all the frozen food from the freezer into the lower fridge compartment. Removed the main shelf. Removed the ice cube tray shelf. Removed the center plastic covers using a nut driver. Removed the complete inside back wall of the freezer to get access to the fan. Simply removed about 5 screws, and cut 3 tie straps that held the wiring in place. Unplugged the fan connector and removed fan with its brackets and placed them on the kitchen table. Then used the nut driver to remove 2 screws which hald the fan to its bracket. Simply pulled off the fan blades and pressed them onto the new motor. Mounted new motor onto the bracket. Reinstalled the fan assembly back into freezer. Reconnected the wiring and the fan began to run... BE CAREFUL NOT TO TOUCH THE FAN WITH YOUR FINGERS!
Finally replaced all the covers, panels, and shelf etc. and everything is once again nice and cold.
65 of 87 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
randy from vancouver, WA
Parts Used:
WR02X11330, WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Wrench set
Water Leaking @ Quick Releases (Blue and White)
Had previously replace the plastic Water Tank, but when installing it I didn't realize how the quick connects worked. Instead of simply pushing inward in the direction of the blue part of the disconnect, I had pulled out the white ring on the outside of the disconnects. This ruined the inside connections and caused them to leak thus requiring these repairs. Had I known that I wouldnt have bought these parts too. Just Always REMEMBER to push in outside white ring on the quick disconnect and as you push it in pull out the hose when you remove it. To put the hose back in, just push it back in without pushing on ring this time at all and it will lock in place, and shouldn't be leaking. I had to run water into a glass to test if it was leaking, otherwise the line had no water pressure.
57 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from Murfreesboro, TN
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
fridge side freezes some items
went to your website and viewed exploded view to find the sensor( there are two I just picked one to replace for now), pried the cover off carfully and pulled out the sensor. I snipped the wire in the middle leaving plenty to work with. I shortened the wire on the new piece, spliced the wires together and with some 3M rubberized, tape wrapped them up, replaced the sensor back into the cover and snapped in place.
54 of 75 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Mancos, CO
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
freezer cold / fridge warm
put fridge into test mode, failed One sensor. Took it out, Tested it, Ordered part also picked up splice kit from electric store spliced it truned on and good to go
46 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Poway, CA
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Water dispenser leaked - tubing broke
Ordered parts from another vendor - got wrong parts (1/4 in parts instead of 5/16 in parts). With your parts, I just cut out the bad portion of the tubing, and replaced it using the 2 union connectors. Thanks.
48 of 65 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Madison, CT
Parts Used:
WR60X10185
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
The freezer was whining and growling like a baby
I replaced the motor that runs the fan in the freezer compartment. Had to remove a number of shields to get to the fan and then some wires and screws to get at the motor. It came with a plug with 4 wires in it and I was supposed to pull 2 wires out of the old plug and place them in the new plug. Long story short the pins would not extract from the plug and the wiring harness was molded in solid plastic, so I ended up cutting the 4 wires to the motor and splicing in the new one and taping them with electrical tape. So far no more moaning and the ice cream is still hard, so I think we nailed it.
43 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
STEVEN from CLARKSVILLE, TN
Parts Used:
WR17X11267, WR17X11170
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Trying to defrost the water line in the refrigerator door I melted (deformed) the plastic parts.
I carefully removed the trim from around the dispenser area then freed the catches in the top of the electronic card. I leaned the card forward and disconnected the electrical connections, then removed the card. I removed the four screws holding the shield to the door and removed the shield. Then I removed the funnel from the shield and removed the spring from the old funnel and placed it on the new one. I removed the light and socket from the old shield and installed the in the new one, then installed the new funnel on the new shield, used the four screws to install the assembly on the door and replaced the trim piece.
47 of 71 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from Bluefield, WV
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice maker quit making ice
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
40 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Averill Park, NY
Parts Used:
WB01X10239
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Halogen bulb beneath microwave lighting the stovetop burned out after 9 mo.
Unscrewed the light cover beneath the microwave with a phillips head screwdriver. The bulb is very tiny and has 2 straight parallel prongs that slide into 2 small holes. Grab bulb from both sides with each hand firmly and slide STRAIGHT out (no twisting or pushing). Don't worry about breaking even though it may take a fair amount of pressure to pull out. New bulb arrived within a couple of days. Due to high shipping cost, suggest buying 2 or more bulbs at once. Bulb is often used as a kitchen night light so that is probably why I only got 9 months out of it.
40 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Greenville, NC
Parts Used:
WR62X23154
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Ice maker dispensed crushed ice but not cubes
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
42 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Sparks, NV
Parts Used:
WR17X11267
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Replace broken ice funnel dispenser cradle
Removed outer trim by pulling it carefully out of its clips. Then disengaged the electronic display card by grabing the bottom of the card to disengage the card from the upper clips. I leaned the card forward and disconnected the wire connectors. Removed the 4 screws to take off the frame that contains the funnel. Remove the broken funnel from clips. Note study how the spring is engaged. Note position of the rubber funnel how there is a gap for the water tube. Removed the rubber funnel and attached to new funnel dispenser. Start at one end of the rubber flap and work around engaging the rubber into tabs. Replace the Funnel dispenser back into frame. Make sure the longer wire of the spring sits flat on the plastic frame and that the right elbow of the spring raps around the edge of the funnel. Secured the frame assembly back into the Refig using 4 screws and attached out trim starting withe bottom tabs engaged first.
53 of 94 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Brentwood, TN
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.
37 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Edgartown, MA
Parts Used:
WR17X22070
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Water if refigerator door is really slow. Ice making is really slow.
Used by pass filter and problem disappeared. Of course wayer is now unfiltered. This is a GE design flaw. Also replacement filters are outrageously expensive and do not last long. We have good water here and I'll stick with the bypass.
41 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!