Customer:
David G from Walpole, MA
Parts Used:
WR17X11459
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
replacing ice maker drive dispensing cup
followed instructions already posted on your website, but had a very difficult time getting the dispensing side of the auger assembly to slide out, even after I disengaged the plastic tabs. There is no easy way or place to grab the assembly to pull it out. Finally turned the unit upside down and pounded on the edges of the assembly with a wood block and a small hammer. Once the part started coming out a couple of inches, I flipped over the ice bin and was able to pull it out the rest of the way, once I had something to grab on to. After the auger assembly was out the cup replacement was easy per posted instructions and the unit snapped back together easily.
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from HAINES CITY, FL
Parts Used:
WR60X10185, WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
Freezer intermittently thawing and refreezing.
Local repairman was called. He replaced the condenser fan motor as it had an intermittent noise several days before. Cost of the repair was 252.00. Two days later freezer was thawing again. He then came back again and said it was probably the evaporator fan and would replace it for 339. dollars or the mother board which he would replace for 500 dollars. He recommended replacing the unit. Since my unit was still in pristine looking condition I decided to do some further research. That is when I found your web site. After reviewing the possible causes on your site I ordered the defrost themostat and and all three thermistors.As a precaution I also ordered the evaporator fan and defrost heater and bracket Assembly. When the parts arrived I disconnected the power to the unit. Removed the shelves and lower pan. Removed the light shield and light bulb. Reovede the two screws holding the evaporator coil cover. This allowed access to the evaporator themostat. I then cut the wires from the old themostat and removed it from the coil. I then stripped the wires on the colored wires and also cut the wires on the new themostat and stripped those. Then using wire nuts I aatached the wires making sure they were properly color coded. Wrapped with electrical tape and attached the new thermostat to the evaporator coil. I then located the evaporator temperature sensor and removed it from the coil and removed the clip and placed it aside for use on the new sensor. I cut the wires and discarded old sensor. Stripped wires on the new sensor after determining the proper length and stripped the wires where the old one was removed and the using in line connectors I first crimped the wires on the new connector and the crimped both wires to the wires previously cut and stripped. Reinstalled the connector to the clip and clipped it back onto the evaporator coil. I then disconnected the wires attached to the defrost heater bracket assembly, located the two screws holding it to unit and removed it from the unit. I did a continuity check on it and it checked ok but was black so I replaced it as a precaution since I already had a new one. Hung the new unit onto the mounting bracket reinstalled the two mounting screws and reattached the two wires. Reinstalled the evaporator cover making sure to reattach the ground wire clip. Reinstalled screws and light cover and all shelves and pan. Reconneceted electrical power. Unit operated fine for a couple of days and then thawed again. I then retraced the steps removing what I had to remove to replace the evaporator fan motor and replaced it per the installation instructions on your site. The unit has now been operating for five days maintaining -8 degrees in the freezer and 37degrees in the refrigerator. I probably could have done a little more trouble shooting at the main board but didn't want to risk damaging that since I already had the parts I thought would fix the problem if it wasn't the main board. I only replaced the one temperature sensor so I will probably return the two I did not use. Thanks for your excellent "how to"videos.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henry from Daly City, CA
Parts Used:
WR50X10068, WR51X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Freezer thaws on top, no fan running in freezer
REPLACING THE DEFROST HEATER & BRA:
1- Empty freezer.
2- Remove all shelves.
3- Remove white painted metal wall plate opposite
the freezer door. There are 2 phillips head screws
attaching it.
4- There may be ice build-up on the freezer coils,
thaw the ice using a hair dryer.
5- Remove the 2 phillips screws holding the
defrost heater to the freezer coil frame, at the
bottom of the frame.
6- Install the defrost heater to the frame.
7- Replace metal panel.

REPLACING THE DEFROST THERMOSTAT.

1-Perform steps 1-4 above.
2-Locate the thermostat at the top of the freezer
coil in the freezer.
3-Cut the wires connecting the thermostat.
4-Connect the new thermostat to the wires that
were connecting the old thermostat, connecting
the wire color to the same color wire.

Note: Connect the wires by using wire splices
available at radio shack. Use splices
sized for 20 guage wire, and wrap with
electrical tape to protect from moisture.

5- Replace metal panel.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from Perkasie, PA
Parts Used:
WR51X10055
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Fridge not cold
On this fridge, you MUST take out the ice maker. First took out the shelves. Then take out the ice maker. This is done by taking out the four screws on the side that hold the assembly containing the bulb. Then there is one screw that holds that assembly to the icemaker. Do not take out any other screws, this is a mistake I made that cost me a few more hours figuring out how to get the other parts to mount correctly to the assembly containing the bulb. The icemaker should lift right out once the white plus is unplugged from the assembly that holds the light. Then took out the shelf brackets and finally could remove rear panel. Found it all iced up as others have. Took 1.5 hours to manually defrost while using sponges to sop up all the water that would run into the drain if you let it. Was about a gallon of water so using sponges worked well. Heater was open when checked with a meter, but you could tell it was blown by the way it looked. All cloudy. Put things back in reverse order. Had an issue with the icemaker shooting water out and missing the icemaker. Eventually was able to align better. This fridge had also just stopped dispensing water. I think the lines may have been frozen in the back, because one day after defrosting manually, the water dispenser started working again Overall this took about 4 hours. But a few days later, the water dispenser again stopped working. Not sure about that one. I have a valve already that I will try for this issue but somehow I don't think its the valve.
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Graeme from Sarasota, FL
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Icemaker flap not closing, frosting up
Watched video, however could not get outer casing off. Under the panel are three small holes, pushed up with an Allen key, used a small screwdriver to wedge out, came out easily, followed instructions from video on removing and replacing solenoid
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
oral from brooklyn, NY
Parts Used:
WR55X10390
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
frig wont start up
type in frig problem partselect gives a solution which in my case was the mother board place an order from parts list watch video provided follow intruction frig works like new thanks partselect
12 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Boca Raton, FL
Parts Used:
WR55X10942C
Difficulty Level:
Difficult
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Ice Dispenser not working
As it turned out much of the electronics is driven by 13.5 volts off the Main Control Board. The Ice Dispenser caused the problem because it over currented the depleted board power. You could hear a clicking noise from the board which was the main relay short cycling and not staying energized. While waiting for the replacement board I unpluged the condenser fan which is a DC motor and uses the Board power. In place of that fan I use a small table top fan to keep the condenser cool. As it turned out I only needed it for 3 days because Parts Select did a super quick job of delivering the new board. Thanks for the super service!!!!!! Removal of the board only required unpluging the electrical connections squezing the retaining board pins with pliers and pulling the board out, pushing on the new board and connecting the electrical plugs. If the board locks like mine did, just unplug the main board power plug, let the memory clear and replug the power plug. The unit should then start and run with no problems.
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
EDWARD from INDIAN WELLS, CA
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Fresh food section lights were all out, but the bulbs tested good elsewhere.
I popped the switch out using the blade of a small screwdriver and noticed that it connected with two wires via a slide on connector for each one. I noted the info on the old switch to identify which wire went to which terminal. I held each wire with a pair of pliers while I pulled the wire connector off the terminal on the old switch. I connected the two wires to the correct terminals on the new swith, and popped the switch back into the door frame. Easy, easy, easy and saved the $40 service call + parts cost!
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jose from La Vernia, TX
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
Water dispenser would not shut off when you released it. It would spill water and run for ten or twelve seconds after removing glass and releasing dispenser.
Ordered the new part (water valve). Took off the bad one followed directions on you video. The video explained the process making it easy to do.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darrell from Long Beach, CA
Parts Used:
WR02X10782
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
door stop broken from fatigue
using a small socket wrench and star shaped driver I (1) removed the two screws that held the broken stop from the bottom of the door, and (2) replaced the new stop and screwed it back in. The most difficult part of the job was opening the door in order to access the second screw.
11 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Raymond, NE
Parts Used:
WR57X33326
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice maker making no ice
I first replaced in-line water filter to the fridge. No ice. Then I replaced the water filter inside the fridge. Still no ice. I inspected the water inlet feeding the ice cube trays and it was froze up with ice. I removed the two screws holding the ice maker in place to remove the ice from the inlet tray. I then used a hair dryer to melt the ice accumulated in the in-coming water tube. Turned off the water and unplugged the fridge. When replacing the old water valve, I first blew through the hose feeding the ice maker to be sure that it was clear of ice. After re-attaching the water hoses and the electrical connections, I turned on the water, plugged in the fridge and turned the ice maker switch back on. Next morning I had ice cubes. Only mystery is I am not hearing the usual water noise when water is feeding the cube tray like I did before, - not to worry though if it works. My drawer is now full of cubes.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
scott from lake orion, MI
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Ice maker door not opening
Removed panel from front of freezer door by pushing up on three spring loaded screws located in the opening where the ice door opens and closes. they are about 1 inch apart on the bottom of the opening. Push up to free ice maker panel. Remove three screws from solenoid, located at the top right. Remove wire, replace with new and that is it. Fixed the problem!! Our ice maker hadn't worked for months. Be careful if you remove the round ice maker door to clean. There is a spring that located on the left side of sprocket. The spring fell off and took me a while to figure where it came from. Recieved package in three days and the job took minutes. Works great! Very easy to complete.
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Stuart, FL
Parts Used:
WR02X10782
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Broken Door Stop
Suggest removing black plastic grill first to gain better access to door stop screws. The grill is attached by two phillips screws, one on either end and several metal spring clips in the middle. The door stop is held by two star shaped screws that are only visible with a mirror. Suggest using a bit attached to a small ratchet.
11 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
chris from GROVE CITY, OH
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
The eavporator coils were completely frozen which prevented fridge-freezer air circulation
1. Removed all food, shelves, and ice bin from freezer compartment.
2. Removed freezer light hood and unscrewed freezer bulb.
3. Removed rear evaporator cover panel (2 Phillip’s screws, 2 hex screws).
4. Melted ice on coils with hair blow dryer (needed bath towels to collected water).
5. Removed old defrost heater (2 Phillips screws, 2 plug-ins).
6. New heater connected without any adjustments.
7. Replaced evaporator cover ice bin, shelves and food.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherrie from COTTLEVILLE, MO
Parts Used:
WR24X20455
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Worn out gasket on freezer
I received part. I then used a hair dryer to smooth out kinks. Took about 15 minutes. Pulled off old gasket and replaced with new one. Used hands only.
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!