TBF16AGR General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- donald from opelousas, LA
- Parts Used:
- WR60X187
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ben from Warrior, AL
- Parts Used:
- WR9X502
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Refridgerator wouldn't cycle into defrost mode without doing it manually.
I removed the shield over the timer and the part that supported the timer. Just unpluged it and pluged in new timer and put back shield. I had already replaced the defrost heaters which had totally burned up. I also replaced the thermostat while I was making the repairs although the old one was still o.k. All the information that I needed to make the repairs I obtained through your website. After looking at several websites to compare prices-etc, I found yours to be the best overall. Thanks-a-million your website is worth it's weight in Cold Food !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Timothy from Orange Park, FL
- Parts Used:
- WR60X30349
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
stopped making ice
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove from hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from BELLVILLE, TX
- Parts Used:
- WR9X502
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
refrigerator wasn't cooling but the freezer was working properly
From instructions found on the site I was directed to the defrost timer part being bad. And from the information others posted that have had the same problem I was able to replace that part by removing the bottom grill just below the door and on the left side was the part. Removing one screw to remove the bracket from the frame and then another screw to remove the part from the bracket. I found it easier to remove the part from the bracket before I pulled the part out so I would have more room to unplug the connector. Just reverse the steps to replace the new part. It took about a day or so for the refrigerator to get to the proper temp.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Cumberland, MD
- Parts Used:
- WR60X114
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
broken fan blade in the freezer compartment
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Keith from Cypress, TX
- Parts Used:
- WR2X7232
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Retainer bars on freezer shelf came loose
Replaced end cap, have had to replace them three times since purchasing the refrigator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from Clinton, MO
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
no water to icemaker
turned off water supply, took screws out of bracket, then unhooked water lines. Installed water lines onto new valve, plugged it in then screwed bracket back onto fridge, turned on water and was back operating
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from FRANKLIN SQ, NY
- Parts Used:
- WR23X37285
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
light not working
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from CONCORD, CA
- Parts Used:
- WR50X55
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Unit would not terminate defrost cycle resulting in melted frozen food
Turn of power to fridge. Removed all shelving in freezer section. Unscrewed back panel from freezer area. Removed old defrost term t-stat from top of evaporator coil assembly. Cut existing two wire leads, spliced in new T stat wires. sealed wire splices from water egress and clipped new t-stat in same position as old one. Reassembled rear panel, installed shelves. Turned power back on.That's it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Provencal, LA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
ice maker barely working
Repair was very simple. Removed refridgerator bottom back panel, about 6 or 7 screws. disconnected bad valve, installed new valve , connected water supply line and then reinstalled panel. Took about 15 minutes from start to finish.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Lafayette, LA
- Parts Used:
- WR9X355
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
unit iceing up in freezer anlower part of fridg.
the temp control is suppose to shut unit down at certain temp....this was not happing , so I tried the new temp control .....that did the trick ...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Betty from Downers Grove, IL
- Parts Used:
- WR30X10154
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Ice bucket cracked
We have an older model refrigerator and thought it would be impossible to find a replacement ice bucket for the freezer. Not only did you have the exact part but it came unbelieveably fast. I would use your website again!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- MATT from OAKLAND, MI
- Parts Used:
- WR9X502
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
freezer cold but refrigerator warm, would not cycle the defrost on freezer
two screws and a connector were removed to replace the timer.
Timer was located on the top front of fridge
Timer was located on the top front of fridge
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kathrine from FORT MILL, SC
- Parts Used:
- WR60X187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
There was a warm spot at the front edge of dividing wall. The fan motor was not working.
I followed the directions of Steve on the installation video. He makes it easy to do the repair with his step by step description of the installation. I have repaired three different aging appliances with help of Steve and PartSelect's very helpful Customer Service.
I wish Steve a wonderful retirement and hope PartSelect can find someone as easy to follow for future videos. The videos are priceless for the repairs.
I wish Steve a wonderful retirement and hope PartSelect can find someone as easy to follow for future videos. The videos are priceless for the repairs.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- O. V. from Virginia Beach, VA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set, Wrench set
Ice maker water valve failed open.
The replacement single outlet water valve was not an exact replacement and required a slightly different mounting position. The original plastic hose to the ice maker attached to the valve with a plastic nut. The new connection requires only pushing the hose into a hole in the valve. Easy and simple. However, the new mounting angle promptly broke the brittle old plastic hose. I was able to pick the broken pieces of hose out of the valve with a fine point pick saving the new valve. If I hadn't been able to pick the broken pieces out of the new valve I would have had to order another one. Off to the big box store to buy new 1/4 inch plastic hose and a coupler. Repair completed and no leaks. If the hose hadn't broken, the I would have been done in 15 minutes. I suggest you plan to replace the entire plastic hose when you replace the valve.
Was this instruction helpful to you?
Thank you for voting!