DSS25MSSISS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Wilbert from Fort Lauderdale, FL
- Parts Used:
- WR60X10220, WR60X10207
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Fan To Cool Condenser Not Working
1. Unplugged the refrigerator 2. Vacuum inside of dust 3. Unscrewed motor and fan 4. Replaced motor then fan 5. Plugged refrigerator bingo! :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from West Union, SC
- Parts Used:
- WR17X22070
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
no problem
I had lost the provided bypass filter plug. I decided to replace it with your part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- justin from brownsville, OH
- Parts Used:
- WR49X10091
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
evertthing in frige was freezing
went online to an appliance repair site and found out that this model has problems with the damper malfunctioning. went to partselect and ordered what I needed and it arrived in two days. to replace the damper you just remove the light at the top of the frige and the cover around it . the damper assembly only has 2 screws and is easy to remove.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Chandler, AZ
- Parts Used:
- WR02X45206
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Cracked Housing Mount - water leak
Turned off the water. Removed the maintenance cover plate on the back of the refrigerator and disconnected the tubing. Removed the tubing cover plate on back of refrigerator. Removed two screws from filter hosing mount on the inside of the refrigerator and pulled the old tubing out. Simply inserted the new tubing and mounted the housing and reconnected the tubing using plumber’s pipe compound. Then re-installed the cover plates on the back of the refrigerator, installed the filter and turned on the water. It was a very easy install.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Neal from Haverhill, MA
- Parts Used:
- WR17X11447
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
old unit was worn out from over use
simply push new ice bucket into position and your done. works better than new! saved 200.00 from calling in a tech for the repair. the part sent is a original GE part not an aftermarket part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- kevin from summerville, SC
- Parts Used:
- WR02X45206
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
low water flow from in door water dispenser
after changing the water filter and having no improvement. I went to the next part of the system. Turned off the water supply. I removed the bottom cover in the back of the refrigerator. unscrewed the nuts on the water supply hose from the main supply and the one going back into the fridge. moved to the inside of fridge and unscrewed two screws holding the filter mount and pulled the tubing through. Reversed my steps and the water flow was great . Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Jacksonville, FL
- Parts Used:
- WR11X10010
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer door lever broke
Unscrew the two mounting screws for the plastic vent plate on the bottom of the SS unit and take the remove the vent. Next, slide the end of the lever through the square hole in the bottom bracket and attach the hook end of the lever to one end of the lever spring. Pull on the other end of the lever spring and slip it over the spring mount finger that is a part of the bottom bracket frame. Finally,reattach the plastic vent plate with the 2 mounting screws. Total repair time was less than 15 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Herbert from Sunriver, OR
- Parts Used:
- WR55X10942C, WR49X10091
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Frozen water filter and food in fresh food side
Initial diagnosis indicated faulty cold air damper, so first action was to remove the light assembly and then the plastic housing that contains the FF fan and damper. The two hidden screws at base of housing required removal of lower decorative plastic duct that turned to be held by snap in-tabs at top and slide away fastener at bottom. The damper housing is held to the roof of the FF chamber by two screws that were taken out to remove the light assembly.
When the plastic housing is pulled towards the front of the refrigerator, the multi-pin wire connector can be disconnected and the damper assembly easily removed.
Installation required need of a thin plate to seat a sponge rubber seal without damage, so I used a thin metal kitchen spatula. Nothing unexpected was encountered in reversing the disassembly process.
Although the new damper corrected the excessive cold situation, the temperature max-min span remained in excess of 15 degrees F, so the control panel was swapped in the small covered cavity located in the outside back of the refrigerator. A 1/4" nut driver and needle nose pliers were all the tools necessary for this operation.
Together the two replacement components have solved the frozen food problem and the over night max-min FF span is now 5 degrees or less.
When the plastic housing is pulled towards the front of the refrigerator, the multi-pin wire connector can be disconnected and the damper assembly easily removed.
Installation required need of a thin plate to seat a sponge rubber seal without damage, so I used a thin metal kitchen spatula. Nothing unexpected was encountered in reversing the disassembly process.
Although the new damper corrected the excessive cold situation, the temperature max-min span remained in excess of 15 degrees F, so the control panel was swapped in the small covered cavity located in the outside back of the refrigerator. A 1/4" nut driver and needle nose pliers were all the tools necessary for this operation.
Together the two replacement components have solved the frozen food problem and the over night max-min FF span is now 5 degrees or less.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Meridian, MS
- Parts Used:
- WR17X11168
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench set
Icemaker supply hose leaking at freezer entrance
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from Williamsburg, VA
- Parts Used:
- WR17X22070
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
No longer needed water filters
Your website was very easy to use and the product shipped very promptly. It was great experience. Thanks!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jamison from Heltonville, IN
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Iced up Freezer compartment in SxS
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Arthur from Alamosa, CO
- Parts Used:
- WR60X10220
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
Condenser Fan Motor stopped turning
1. Unplugged the fridge. 2. unplugged the fan connection and removed the wire holding clip. 3. removed the 2 screws holding the motor bracket in place and removed the bracket. 4. Pulled gently back on the motor so that the fan pressed against the front bracket until the fan slid off the motor shaft. 5. Pulled the rubber motor mounts off of the old motor and placed on the new motor. 6. Slide the new motor in place pressed the fan all the way onto the shaft. 7. Placed the rear motor bracket in place and started the screws by hand making sure the ground wire was attached to the furthest away screw. 8. tightened the screws down. 9. Pushed in the wire holding clip into the clip hole. 10. Plugged back in the fan. 11. Plugged back in the fridge. 12. Turned down the temp on the fridge to kick on the compressor and checked to assure the fan was operating and then set the temp back to normal. 13. Vacuumed the condenser coils to get them all clean and ready for more years of service!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Deanna from MANDAN, ND
- Parts Used:
- WR01X10450
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Fridge handle missing set screw.
Opened the package. Set screw fell on floor. Luckily cat found it right away. Fight the cat for the screw. Dug through my tools and the first Allen wrench I picked up fit. "What the hell? That never happens so obviously the screw won't fit," I think to myself. Put the screw in the hole and give it a few turns until my fat finger can't hold it. It's a miracle and the thing fits! Fight the close quarters with the Allen wrench to tighten it. Works like a charm!! Now I don't scare myself when I open the door thinking I'm going to rip the handle right off. Now I have easy access to my ice cream. The parts finder tool on the website was really easy and I found what I was looking for.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Hanford, CA
- Parts Used:
- WR01X10315
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Ice Maker auger blade broken
The ice machine auger blade broke a chunk off. I decided to try to replace it myself. I bought the new auger blade and then sat there and stared at it and the ice machine for a few, trying to figure out how to change out the part. Turns out it was a qute lengthy process. The auger is threaded on one end and the ice chopping blades are on it. So I had to take each blade off the old one and put it on the new one. The blades have to be positioned just right on the shaft so it's best to just draw a line down over all the blades so as to put them on the new auger successfully. The problem I had was the end cap that screwed on the end of the shaft. It was the part I ordered here. It is made of plastic with plastic threads and at first I couldn't figure out to get it off. Turns out the threads are opposite normal. By the time I figured that out, I had just about destroyed the cap using pliers to try to unscrew it. There is a washer and half moon clip that fastens on this end nut so if you mess the nut up, chances are you won't be able to get the half moon clip to go back on. I finally did it right and now how the ice maker working right again. A hard part for me was figuring out how to set the spring shaft that works a lever to either give cubed ice or crushed. I had to keep fiddle with it before I finally got that right. At first I was only getting crushed ice even with the cubed setting and then only getting cubed ice with the crushed ice setting. After some fiddling, I got both to work but to this day can't figure out what changes from the crushed setting to the cubed setting.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Spring, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
"Moaning Myrtle" syndrome. Refrigerator makes a whooing sound for hours at a time
Checked the internet for reports of similar problems and concluded that it was probably the main control board. Not being particularly handy, I would never have attempted to change the board myself if I had not read the comments and instructions from people on this site. Thanks.
The job was as straight forward as others have described. The only time I had a problem was pushing in the white tab to be able to pull the old board out. That was a bit of a fiddle.
The only thing I found different was the grounding wire. On the original board, this wire was at the bottom of the board and hooked into a wire that ran into the refrigerator. On the new board, the wire was at the top of the board and had a metal loop on it. If I understand it correctly, with the new grounding system the wire is pushed into the space above the board. Then when the back plate is reattached the metal loop makes contact with it , thus grounding the refrigerator.
I chose to run the grounding wire through the original wire into the refrigerator. That meant cutting off the metal loop, slicing in an extra piece of wire to connect the grounding wire on the board to the grounding wire into the refrigerator.
I also now use a surge suppressor for the refrigerator. The “Moaning Myrtle” syndrome started after Hurricane Ike. I suspect the surge when the power was restored damaged the control board. And as so many people seem to have this “Moaning Myrtle” problem, I suspect the control board has little or no surge protection.
The job was as straight forward as others have described. The only time I had a problem was pushing in the white tab to be able to pull the old board out. That was a bit of a fiddle.
The only thing I found different was the grounding wire. On the original board, this wire was at the bottom of the board and hooked into a wire that ran into the refrigerator. On the new board, the wire was at the top of the board and had a metal loop on it. If I understand it correctly, with the new grounding system the wire is pushed into the space above the board. Then when the back plate is reattached the metal loop makes contact with it , thus grounding the refrigerator.
I chose to run the grounding wire through the original wire into the refrigerator. That meant cutting off the metal loop, slicing in an extra piece of wire to connect the grounding wire on the board to the grounding wire into the refrigerator.
I also now use a surge suppressor for the refrigerator. The “Moaning Myrtle” syndrome started after Hurricane Ike. I suspect the surge when the power was restored damaged the control board. And as so many people seem to have this “Moaning Myrtle” problem, I suspect the control board has little or no surge protection.
Was this instruction helpful to you?
Thank you for voting!