- Customer:
- Blake from Cincinnati, OH
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
ice flap would not open
I was this close to calling a repair man when I stumbled upon this site. I would not have been able to attempt this relatively easy repair has I not seen the posts from people with the same problem. It was simple to pop off the cover and replace the selenoid using only about 8 screws total. Thanks to posts by other DIY'rs it was an easy job--this site is Great!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from hudson, NH
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frost accumulating above ice chute in freezer
Using a small phillips I removed the plastic module containing the ice/water selection buttons by sequentially inserting the screwdriver into 3 holes just underneath the module in the chute opening and pushing up on the tabs while pulling out on the module. Pulling the module away exposes 4 screws that are easily removed allowing you to remove the chute assembly. The solenoid is removed by removing 3 screws and pulling the clip containing the solenoid wires off the electronics board. Reverse the process to replace.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gregory from Simi Valley, CA
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The ice-maker flapper door stays open slightly.
I watched the video on this site and read the comments here. Everything went as stated. I simply removed the front cover from the door, carefully pushing in the two plastic dimples to release the plastic piece. I used a very small screwdriver to get in the holes and pushed carefully while gently prying on the piece. It popped right out. I then carefully removed the three wire harnesses from the back of the cover. I then removed the four phillips screws that hold the cup pushing assembly on. I found this piece to be rather dirty/black moldy. I spent more time cleaning this with a toothbrush and soaking it than I did with the total repair of the solenoid, but I have much better piece of mind. I could now reach the solenoid, on the upper right hand corner. I removed the three screws and the solenoid was left hanging by the rusted top hook. I gently wiggled it off of the plastic arm that operates the flapper door. The new solenoid comes with the clip able to move freely and with no rust. Install the new solenoid in the same place and place the top hook onto the arm for the flapper door. Note, I WD40ed the screws and filed some of the rust off of the heads. I suggest ordering screws, like everybody says. But you can clean them up. I did this just in case I need to do this install again. The rest is just a matter of buttoning up everything. It is easy, don´t be intimidated. Anybody can do it, if you are the least bit handy and patient.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Martyn from Oswego, IL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice dispenser flapper would not close
I followed the instructions that were posted on the partselect website and the video tutorial. It really was as simple as everyone had commented. Like others have noted, once the small tabs on the bottom of the faceplate were released, the cover came right off. Unplug the wire connectors, don't force them off. Remove the four screws and voila, there's the whole system laid out in front of you. It took me longer to clean up all of the gunk that had built up over the years. Once the new part was installed, everything went back together veray easily. The machine works like new again. Thanks partselect, you saved me some serious $$$.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wolf D from Turnersville, NJ
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Dispenser Flapper Stays Open
Changed out solenoid and plunger (comes as a kit). Repair was really easy and saved an expensive service call. Note: it is probably a good idea to get screws to go with the solenoid assy (qty 3) plus the screws that hold the dispenser plate to the door (qty 4). Mine were rusty due to the normally moist environment and had rusted, making their extraction more difficult than it had to be.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eugene from Fort Pierce, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Ice cube door didn't close
Remove dispenser assembly in freezer door & replace solenoid.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Fort Myers, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Soloinoid did not close valve controling ice cube dispenser and ice accumulated, eventually blocking off shaft ice cubes were dispensed
Removed controls face plate by inserting small screw driver into small holes located below the face plate releasing internal fastening catches and permits you to pull the face plate down and out toward you. Remove the electronic panel now exposed covering the solenoid by removing the 4 screws in the corners. Detach the electrical connector leading from the solenoid ( It may be prudent to unplug the refrigerator as a safety proceedure). Proceed to remove 2 screws holding the solinoid. If the sollinoid is corroded and difficult to remove and disengage from flap(door) controling the ice shaft aperture, it may be necessary to remove the flap by removing 2 small screws holding it in place. Be careful to note the small spring on the left hand side of the shaft which the flap rotates around since it to be re installed in the proper position when the parts are reassembled since it closes the flap after it is opened by the solonoid.
Reconnect the parts and and snap face plate back into place. Good Luck
Reconnect the parts and and snap face plate back into place. Good Luck
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jer from Mercedes, TX
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Icemaker door did not close
Used awl tto release the front panel. Used screw driver to release the solenoid. Ordered a new solenoid. Reverrsed the removal
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sarah from Marion, KY
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
frost build up in the ice chute
We removed the front panel by using a screwdriver underneath the panel to push three little tabs up to unlock the panel. Next we removed the mother board. Removed the old solenoid and put the new one on. It was very easy. We cleaned all he parts that were covered with mildew (yuck) and reassembeled all the parts. Very glad we found this source to do it ourselves. Will order more parts if needed from PartSelect.com
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Sarasota, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Flap on Ice maker was stuck
My son repaired the ice maker so my report will not be valid other than the service was as good as it gets.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- chris from Marco Island, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frost on Ice Maker opening
Pulled off fountain face plate. Removed four screws holding the plate in front of solenoid. Disconnected solenoid wires away from electronic board. Removed three screws holding solenoid arm.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Fort White, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
No Water dispensing
Took about fifteen mins. to remove the three screws and slip out the solenoid and replace it. Only one electrical connection. Super easy to do. Unfortunately this did nothing to solve the problem. I still have no water. Nor did replacing the switch or the water valve solve the problem. I guess I'm done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patricia from Croton on Hudson, NY
- Parts Used:
- WR62X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Ice maker freezing up and not dispensing cubes
I tried to follow the video...it looked easy enough to do and would have been if the trim came off! I had to go to the reviewer who said to undo the 3 springs under the keypad (found on the white part behind the touchpad). I just took an eyeglass screwdriver and pushed up...it was easy to follow the solenoid installation video from there! If I can do it...anyone can! I'm a 65year old female.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Idichandi from Coppell, TX
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Ice maker door was not closing.
Changed after watching U-Tube instructions. Faced trouble with the magnet assembly, had to redo it again, and it worked.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Geoff from Media, PA
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Ice dispenser door failed to close, affecting temperature in both freezer and refrigerator - temporary solution of jamming towels down ice delivery chute provided a partial remedy to temp problem but required opening door to access icemaker
Watching the outstanding, detailed video provided the insight and confidence necessary to place the part order and complete the repair. The most difficult part of the procedure was removal of the front panel that identifies the buttons for various functions (i.e. water, ice, crushed ice, etc). Note that this panel differs slightly from one model to another so the process may be slightly more difficult than pictured in the video. Our refrigerator has removable decorator panels which I removed first (both above and below the dispenser section), an additional step I strongly recommend for owners of models with such panels. To do so, a male Torx socket is required to remove screws at the top of the door, allowing the metal side panel on the left to be removed, prior to sliding the decorator panels out. Now onto removing the front panel as in the video - although the video repairman completed this step without any tools, it must be CAREFULLY pried by hand. Experience has taught me that older plastic parts that "snap in" often become fatigued and suffer stress fractures if not breaking off entirely. This is a fairly rigid piece of plastic on our unit that wasn't cooperative until I coaxed it from one (left) side with a large, flat screwdriver and a little twisting motion to get things started. Once I was able to pop one corner loose, the other 7 connecting tabs were relatively easy to remove (there are 8 total - 2 on each side as I recall). The rest of the process was simple, exactly as demonstrated in the video. Thanks SO MUCH for all of the expertise and high production values that made this repair "a piece of cake". Incidentally, by simply removing the old solenoid ASAP, the door snaps shut, sealing off the freezer compartment while you wait for your new part to arrive.
Was this instruction helpful to you?
Thank you for voting!