PSM27SGMABS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Scott from SMITHS GROVE, KY
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Replaced Dispenser Solenoid Assembly
We had problems with the ice dispenser chute building up frost from condensation freezing due to the flap not closing properly. It would clog up completely and often. I had already replaced the flap and spring years ago but it didn't help much. I Googled this problem for my model and found a video detailing how to check and change the solenoid. Sure enough, the solenoid was completely corroded and crumbled in my hands as I removed it. I ordered the replacement part and made the repair myself. The video was perfect in describing. If your refrigerator is well used as ours is, you'll be shocked by the buildup and cleaning that will be necessary as you make this repair. I ended up taking much more of the dispensing assembly apart so I could clean it with warm soapy bleach water. Be mindful as you disassemble or take photos / videos with your smartphone to help put it back together. It took longer to clean than replace the solenoid. Also, be careful if you have an island or other cabinetry close by. If you have to pull the refrigerator out to unplug it, the handles can chip granite edges or the top corners can scratch wood work. We have cherry cabinets that surround ours. I chipped the edge of the granite when I pulled it out and I scratched the wood as I pushed it back in place. Minor repairs but can save you some frustration. Good luck!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ERIC from THE VILLAGES, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Flapper Door stuck open
The only tricky part was removing the front panel. Releasing the latches required considerable force. The best tool I found was a "jack knife" type Allen wrench set, using the medium size wrench, which fit into the release hole and upward pressure did the trick. The rest of the job was very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jeffrey from MAINEVILLE, OH
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
ice maker door wouldn't close
just watch video simple
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Richmond, VA
- Parts Used:
- WR62X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Ice wouldn't come out of door. It backed up in door
I followed the instructions on a posted desctiption. It workded perfectly. Replacing the inner door panel was not as difficult as described. Just start the process with the screws in the middle of the door. Those two screw holes were not slots. All of the remaining screw holes had slots. I installed all of the door screws before tightening any. I workded right the first time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- DALE from OLATHE, KS
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ice machine trap door not opening or closing
Fairly simple fix. You must first uplug refrigerator, then take off the inside freeze door panel, approx. 25 screws. Then you must take out the trap door assembly approx. 6 six screws. Pop off the LED panel, requires the use of a flat blade screw driver to pop it off. Remove solenold by removing 3 screws, replace with new solenold.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- david from LANSING, NC
- Parts Used:
- WR62X10055
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken Ice maker dispenser
with a philips screw driver and that's all it was that easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from TYLER, TX
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Your video was wrong. Your step was to remove exterior frame on ice/water outlet. No need to remove.Wasted too much time trying to remove.
Remove control panel.
Remove four screw in control panel bracket.
Remove to bottom screws at bottom of solinid loose top screw.
Replace all screws.
Remove four screw in control panel bracket.
Remove to bottom screws at bottom of solinid loose top screw.
Replace all screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from AVON, OH
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Flap on ice maker would not close
First tried just replacing flap/spring and mounting. Still did not work so then order a new solenoid with piston that attaches to mounting. That solved problem completely. Corrosion around piston prevented fluid movement of flap. Easy fix after watching video. Saved a bundle I'm sure. Thanks !!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from FORT MYERS, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The flapper on the ice dispenser would not close after you dispensed ice cubes
Removed face plate, which holds the circuit board. Removed the next section be removing the 4 screws that hold it in place. Then removed the old solenoid, and replaced it with the new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- NICK from COCOA bEACH, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice dispenser door will not shut completely
I removed the door cover plate and disconnected the circuit board, then four screws. The part was corroded in place. Upon removing three screws and cleaning the surface, the new part was an exact fit, replaced it and everything works like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Sandy Hook, CT
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice chute wouldn't open or shut correctly - rusted solenoid
Replaced rusted solenoid.
Popped front button panel off from the bottom using flat head screwdriver; Removed 4 screws holding electronics board and disconnected wires. Unscrewed 3 phillips head screws on old solenoid and replaced with new part. Reconnected wires to board, screwed back in, and pushed panel back into to place.
Thumbs up to PartSelect - fast, straightforward service and fast delivery.
Popped front button panel off from the bottom using flat head screwdriver; Removed 4 screws holding electronics board and disconnected wires. Unscrewed 3 phillips head screws on old solenoid and replaced with new part. Reconnected wires to board, screwed back in, and pushed panel back into to place.
Thumbs up to PartSelect - fast, straightforward service and fast delivery.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jeff from stillwater, OK
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
solenoid quit working
repair was easy, just removed control panel and removed screws from solenoid, switched out with new, was done in minutes
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from W Berlin, NJ
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice forming around shoot. Flapper door not shutting letting warm air in.
I followed they instructions from the other "do it your selfers" but only replaced the solenoid. This was the cause. Rust was keeping solenoid plunger from moving and this held the flapper door open. Very easy to repair!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Resa from Potomac Falls, VA
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Flap on Ice Maker not closing
I searched the site, found the part - solenoid, watched the "how to" video and the repair was a snap. Saved myself tons of money versus having a repair person come over. I do have an older model and needed to prop the front cover panel off with a screwdriver (just under the covering) saw this on a posting from another individual, thanks for the heads up.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vonda from Hendersonville, TN
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
The Ice dispenser tube in the door would accumulate ice
We followed the instructions we found on this site.
First we unplugged the refrigerator.
Then we removed the control panel that has the ice type selection on it by releasing the three spring latches. These are accessible from the bottom of the panel looking up toward the ice dispenser. There are three holes. Press a narrow screwdriver or punch in each of these holes and then pull out the control panel. (Be careful not to disconnect the wires, but observe how the wires are routed.)
Then we removed the ice tube cover that covers the solenoid assembly. There were four screws. One was very rusty and it required some WD40 to loosen it. Once the cover was removed the solenoid was visible on the right. (It has a floating component that attaches to the "arm" of the flap. This is how the solenoid opens and closes the flap. The flap needs to close properly so ice does not build up in the door.)
There were three screws that had to be removed to get the solenoid out. (The top one you may just need to loosen once the bottom two are removed.) When the solenoid was removed we also removed the old floating component from the flap are and replace it with the new one. We slid this into the solenoid hole and then screw it in with the three screws.
Before we attached everything, we plugged in the refrigerator to test the solenoid. We dispensed some ice and waited to hear the flap close. (The flap close is slightly delayed so be patient.)
We attached the cover that was over the solenoid being careful to route the wires as they were when we started. We test the solenoid again. Then we snapped the control panel back into place and tested again.
We found that having the right size screwdriver made a difference especially dealing with rusty screws. It was also handy to have a good flashlight. Having extra hands was helpful to hold the control panel and cover while working on the solenoid and routing the wires.
First we unplugged the refrigerator.
Then we removed the control panel that has the ice type selection on it by releasing the three spring latches. These are accessible from the bottom of the panel looking up toward the ice dispenser. There are three holes. Press a narrow screwdriver or punch in each of these holes and then pull out the control panel. (Be careful not to disconnect the wires, but observe how the wires are routed.)
Then we removed the ice tube cover that covers the solenoid assembly. There were four screws. One was very rusty and it required some WD40 to loosen it. Once the cover was removed the solenoid was visible on the right. (It has a floating component that attaches to the "arm" of the flap. This is how the solenoid opens and closes the flap. The flap needs to close properly so ice does not build up in the door.)
There were three screws that had to be removed to get the solenoid out. (The top one you may just need to loosen once the bottom two are removed.) When the solenoid was removed we also removed the old floating component from the flap are and replace it with the new one. We slid this into the solenoid hole and then screw it in with the three screws.
Before we attached everything, we plugged in the refrigerator to test the solenoid. We dispensed some ice and waited to hear the flap close. (The flap close is slightly delayed so be patient.)
We attached the cover that was over the solenoid being careful to route the wires as they were when we started. We test the solenoid again. Then we snapped the control panel back into place and tested again.
We found that having the right size screwdriver made a difference especially dealing with rusty screws. It was also handy to have a good flashlight. Having extra hands was helpful to hold the control panel and cover while working on the solenoid and routing the wires.
Was this instruction helpful to you?