Models > GLM23KESBGS > Instructions

GLM23KESBGS General Electric Refrigerator - Instructions

Jump to:

All Instructions for the GLM23KESBGS
31 - 45 of 95
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Donald from Secretary, MD
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice chute door not closing
I read instructions in all of the other repair stories everything went smooth no problems. Went and examined freezer door too see which type of door I had front or rear access. Popped off front LED panel, unpluged wires, removed 4 screws holding ice chute, removed 3 screws holding solenoid, slipped off solenoid pin, replaced all items in reverse order. This is one great site.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Howard from Shelby Twp., MI
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flap to ice dispenser would not close
I followed the video provided, and followed the advice of bill from cleveland hts. ohio, and did not have to remove the trim to access everything. The video made it so simple, a monkey could have learned how in 5 minutes. Thank you very much for all the help on this website. I will recommend it to all.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Clifford from Goose Creek, SC
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Sticky ice maker chute door
The model we have, the front panel snaps into place. It was removed for access and the electrical connectors unplugged. Four screws and the chute assembly was removed. Removing three screws and opening the chute door allowed the solenoid assembly to be removed without removing the door assembly. All parts and area were cleaned and the assemmbly was the process in reverse.
Guideline to prolong recurrance: always put ice into glass first to reduce splashing of ice falling into liquids causing the solenoid armature to rust and stick.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
james from apex, NC
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
replaced the ice flap solenoid
I followed the instructions posted by previous custmers and they were accurate and simple
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Colin from Saint Helena Island, SC
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Bad Solenoid Not Closing Ice Dispenser Door
Followed the on line video. Clear, concise & easy. Thanks.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Warren from Merrimack, NH
Parts Used:
WR62X10055
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Ice dispenser door not closing after dispensing ice
First remove trim surrounding ice/water dispenser assembly. Use a flat spackle knife to obtain space between door and trim. Be careful not t scratch refrigerator door. Then pry trim off. This was the most difficult part of repair. The front plate of the dispenser is held to the back of the dispenser by two friction fastners and in the case of my refrigerator a phillips screw (some don't have screw in middle). Use a small round tool like an allen wrench to push up on the 2 fastners to release them. Next push the front assembley aside and remove the 4 screws holding the back part of the dispenser. Push that assembly aside. Remove the defective solenoid assembly by removing the 3 mounting screws. The solenoid base can be worked out by slipping it out of the solenoid assembly plunger still attached to the dispenser door assembly. Next slide the plunger off of the dispenser door assembly. Install new solenoid assembly by reversing this procedure.
Hint - I found the ice door assembly (wr17x11653) also needed replacement and it is well worth the effort to replace both at the same time.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Vonda from Hendersonville, TN
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The Ice dispenser tube in the door would accumulate ice
We followed the instructions we found on this site.

First we unplugged the refrigerator.

Then we removed the control panel that has the ice type selection on it by releasing the three spring latches. These are accessible from the bottom of the panel looking up toward the ice dispenser. There are three holes. Press a narrow screwdriver or punch in each of these holes and then pull out the control panel. (Be careful not to disconnect the wires, but observe how the wires are routed.)

Then we removed the ice tube cover that covers the solenoid assembly. There were four screws. One was very rusty and it required some WD40 to loosen it. Once the cover was removed the solenoid was visible on the right. (It has a floating component that attaches to the "arm" of the flap. This is how the solenoid opens and closes the flap. The flap needs to close properly so ice does not build up in the door.)

There were three screws that had to be removed to get the solenoid out. (The top one you may just need to loosen once the bottom two are removed.) When the solenoid was removed we also removed the old floating component from the flap are and replace it with the new one. We slid this into the solenoid hole and then screw it in with the three screws.

Before we attached everything, we plugged in the refrigerator to test the solenoid. We dispensed some ice and waited to hear the flap close. (The flap close is slightly delayed so be patient.)

We attached the cover that was over the solenoid being careful to route the wires as they were when we started. We test the solenoid again. Then we snapped the control panel back into place and tested again.

We found that having the right size screwdriver made a difference especially dealing with rusty screws. It was also handy to have a good flashlight. Having extra hands was helpful to hold the control panel and cover while working on the solenoid and routing the wires.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Austin, TX
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Corroded ice chute flap solenoid - replaced
Squeezed a flat blade screwdriver between the faceplate (buttons and lights) and the plastic part behind it and the front panel popped loose. I unscrewed the 4 cross-slotted screws on the panel behind the faceplate and could easily see the solenoid. I released the solenoid connector from the printed circuit board and removed its 3 screws. It slides out. Replace with new part in reverse.
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Palestine, TX
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice dispenser flap would not close causing frosting up of ice tunnel
First I used an ice pick to punch the tabs under the control panel to remove the ice/water selector panel. Then I used a phillips screwdriver to remove the solenoid switch. Unplugged the switch and re-installed with new one I received in 2 days and shazaam it works like new.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from hudson, NH
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Frost accumulating above ice chute in freezer
Using a small phillips I removed the plastic module containing the ice/water selection buttons by sequentially inserting the screwdriver into 3 holes just underneath the module in the chute opening and pushing up on the tabs while pulling out on the module. Pulling the module away exposes 4 screws that are easily removed allowing you to remove the chute assembly. The solenoid is removed by removing 3 screws and pulling the clip containing the solenoid wires off the electronics board. Reverse the process to replace.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wolf D from Turnersville, NJ
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Dispenser Flapper Stays Open
Changed out solenoid and plunger (comes as a kit). Repair was really easy and saved an expensive service call. Note: it is probably a good idea to get screws to go with the solenoid assy (qty 3) plus the screws that hold the dispenser plate to the door (qty 4). Mine were rusty due to the normally moist environment and had rusted, making their extraction more difficult than it had to be.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
patricia from Westminster, CA
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
replace rusty solenoid
I followed the easy video online that was mentioned in the paperwork that came with the part. The day before I replaced the flapper door for the ice chute and when I saw the rusted solenoid I immediately ordered that part which arrived the next day. I did not need to remove the border around the water/ice dispenser access area as shown in the video to install the parts. I did use a tiny screwdriver to press the little tabs on either side at the bottom of the front panel to release it to get to the parts. I was able to remove and replace the solenoid within minutes. And this was my first ever appliance repair attempt!
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rebecca from Prospect, KY
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
flapper for the ice dispenser would not close completely allowing frost to build up in the freezer ice dispensing compartment
I watched the video explaining how to do this and it was a snap. MY PROBLEM WAS COMPLETELY SOLVED. Partselect.com is a must for my household. I couldn't be happier!!!!!
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from Clarksburg, NJ
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice flapper door not closing
Removing the trim ring around the control panel is the hard part. Be sure to watch the video on how this is done.
Follow the video instructions on how to remove the solenoid and you will not have any trouble.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
david from New York, NY
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice Dispenser Door Does Not Close
Replace solenoid which controls the despenser door. It is usually rusted. The front panel snaps off easily. Then there are 4 screws for the panel. Once the panel is off, the solenoid is exposed. There are 3 screws for the solenoid. You may want to spray dw40 on the screws if they are also rusted. Make sure you turn fridge off before performing this repair.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GLM23KESBGS
31 - 45 of 95