TFJ22PRDAAA General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Mary from WESTON, CT
- Parts Used:
- WR30X10093
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker stopped working
Installation could not have been easier!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Grand Forks, ND
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Water valve cracked
Pulled out the fridge - unpluged. Water supply was already closed.
Then took off the cardboard cover in the back. Used a nut driver to remove 1 screw. Disconnected water lines and elec. connects.
Water lines slid into quick connects - connected electrical and mounted. Opened water suply needle valve.
Pluged in fridge did a quick test for leaks. Done in 5min.
Then took off the cardboard cover in the back. Used a nut driver to remove 1 screw. Disconnected water lines and elec. connects.
Water lines slid into quick connects - connected electrical and mounted. Opened water suply needle valve.
Pluged in fridge did a quick test for leaks. Done in 5min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Fort Collins, CO
- Parts Used:
- WR32X1461
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
drawer was broken
The replacement part fit perfectly and was easy to install. No problems at all.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tony from Charlotte, NC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Water won't stop running in Ice Maker
Basically I looked online for some research thru google and found this great site.. A few other folks had the same problem as I had with mine and I figured that I would start with replacing the double outlet water valve.. So I ordered it from this site and in two days wow that's fast shipping.. This repair took less than 15 minutes to complete and talk about a big savings $ 45.00 for this repair job.... I'm really happy now.... It's pretty easy though.. simply unplug frig first... then remove screw holding the valve.. remove clips and have a bowl near by when remoing the two hoses... replace valve.. its all colored coded just match the colors and then the two hoses they are different sizes one for each hole... reclip the clips and then replace the screw and finally plug the frig back in.. and then turn on the water to check for leaks.. if no leaks you are done...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Purcellville, VA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Fridge evaporator coils frozen
Determined that the defrost heater was bad (didn't test the thermostat or sensor) and attempted to replace it first.
Got the part in one day (super fast shipping).
1) Removed back panel on the inside of the freezer compartment using a nut driver.
2) Removed the ground wire clip from the metal panel
3) Used a screw driver to remove the two philips head screws that hold the heater assembly in place.
4) carefully pulled off the wires attached to the assembly.
5) attached the wires to the new heater
6)attached the new heater and screwed the new heater in place
7) attached the inside panel
8) fridge is now working great.
Got the part in one day (super fast shipping).
1) Removed back panel on the inside of the freezer compartment using a nut driver.
2) Removed the ground wire clip from the metal panel
3) Used a screw driver to remove the two philips head screws that hold the heater assembly in place.
4) carefully pulled off the wires attached to the assembly.
5) attached the wires to the new heater
6)attached the new heater and screwed the new heater in place
7) attached the inside panel
8) fridge is now working great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Schenectady, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
No Defrost - Top of freezer thawing
By the time this failure (failed defroster heating element) is evident (top of freezer starts thawing), the entire freezer coil is encased in a block of ice & frost is visble on the back freezer panel.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GARY from SPRAGGS, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ran All The Time Did Not Freeze.
Removed cover in freezer over evaporator,unbolted element ,plugged ,and replaced, very simple. Should be first thing checked when theres a problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Middleville, MI
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
refrigerator not cold
I called the repair tech who obviously did not want to come out, thank god. He told me to remove the back panel of the freezer and also check fan on back side. Told him there was alot of ice on freezer condenser and he advised that defrost heater was probably shot, and referred me to partselect.com. I unplugged the frig/freezerer, and removed the heater and saw it was blackened and cooked. I used a hairdryer to thaw the condenser, and the new part arrived the next day. I reattached the 2 plugs, 2 screws, and put the back panel of the freezer back on. I plugged the appliance back in, checked it 6 hours later and the frig is cold again. It was a VERY easy repair and took less than 30 minutes from start to finish. I was quoted between $40-$78 for the part at 3 different places in the phone book, which would have also required a 45 minute drive. I got it here for $38 including shipping and it arrived in 24 hours !
With the "blow-up view" appliance feature on this web-site, and simply being guided to the correct part by entering the model number, it was a very easy ordering process and repair.
With the "blow-up view" appliance feature on this web-site, and simply being guided to the correct part by entering the model number, it was a very easy ordering process and repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kyoko from Bellevue, WA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
frost/ice buildup in icemaker chute in the freezer door
The only difficult part was not knowing which parts had to be removed to gain access to the flapper to replace it. It appeared as if the frame around the control panel would have to be removed as well as the door handle; we tried but were not able to remove the frame. It turned out that the panel just popped out with the frame in place. Once we had access to the flapper, it was easy to replace it. The repair fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Hills, IA
- Parts Used:
- WR62X23154
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Crushed Ice Only
Let me start by saying, I usually hire something like this out but figured I would give it a try. The install was fairly straight forward, however it would’ve been nice if the instructions would have been more useful. Instructing me to remove one screw to release the auger and solenoid enclosure wouldve been nice. There were 3 other screws that I didn’t need to remove and they were the ones holding the auger in place, which made assembling that much more difficult. Once to enclosure was removed, and the solenoid was exposed, it was a seemless process. I would however, recommend paying attention to or taking a picture of the connections on the solenoid. I was lucky to remember or got lucky. Regardless, I was able to complete the project successfully. If I had to do it again, I believe it can be done in 30 minutes or less.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Lake Quivira, KS
- Parts Used:
- WR71X10196
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Plastic Left Ice Bucket Shelf (slide) at the back broke around the pop rivet into the shelf .
At the front of the shelf there is a Phillips metal sheet metal screw that holds the front of the shelf in place. Its removal was fairly set straight forward but removing the pop rivet was awkward and took some time to drill out from the rear metal shelf. Once the rivet was out, it was easy finding a small screw that would hold the shelf in place since I didn't have any pop rivets that would fit sufficiently tight or long enough.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Sarasota, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Open defrost heater
The most difficult part of the repair was the melting of the ice and preparation. I did change a single element heater for a dual element heater, which required a little manual flexing of the sub-frame, but it assembled with little issue. I was lucky, I did not have to splice the extended harness connection. Rerouting my existing gave sufficent length.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Longs, SC
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer building up Ice
This is such an easy fix!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tony from Conover, NC
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench set
Water leak from the Water Valve.
I received my parts in 2 days, that is fast. It took me less than 15 minutes to install the unit. Now I've got ice and water from my refrigerator. Instead of taking expensive warranties, I would rather order parts from your company and do it myself on all my appliances.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roger from Colleyville, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
No water through door dispenser
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Amazing.
Was this instruction helpful to you?
Thank you for voting!