Models > ZISW42DCB > Instructions

ZISW42DCB General Electric Refrigerator - Instructions

Jump to:

All Instructions for the ZISW42DCB
31 - 45 of 513
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Rich from Keller, TX
Parts Used:
WR57X10026
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Wrench (Adjustable)
Water Valve Leak
Pull fridge out and turned water supply off. Removed four screws to take shield off back of fridge. Unscrewed assembly part from fridge. Turned water on slightly to identify leak and identified leak in valve system. Shut water back off and ordered replacement part. When part came, removed water line from assembly; moved electrical and water hose connections from existing part to new part one by one to be sure t they were in correct place. (To remove water lines, push o ring toward the assembly and pull hose out. To put into new bracket, merely slide in and they will lock in place) Fasten water line on new part using teflon tape. Turn on water slowly to check for leaks. Attach back to fridge and replace shield. VERY EASY!!
22 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from worthington, OH
Parts Used:
WR9X502
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
refrigerator would not defrost
Look were timer was located, in my refigerator is next to the dial to ajust the temperature. used a screwdriver to get panel off. replaced timer then used a straight screwdriver to advance timer to turn on compessor . monitor temperature . checked out.
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
george from palmetto, FL
Parts Used:
WR23X366
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Wouldn't dispense ice
First pried off front panel, then removed 4 screws that hold dispensing unit in place, then rotated top of dispensing unit out, then pulled off electrical connector, then removed screw that holds switch in place and removed switch. Installed new switch by reversing above procedure. Only thing switch wasn't the problem. No ice problem was resolved later by replacing control printed circuit board which is located in the same area.
24 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Glendale, AZ
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Chesapeake, VA
Parts Used:
WR17X4312
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
dirty ice from rusty auger
Removed old bucket/auger assy from frig. Removed 4 + screws from front cover. Put front cover on new bucket/auger assy. Reinstalled in frig.....done. now have clean ice.
19 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jania from Novato, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Mebane, NC
Parts Used:
WR29X5171
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Ice maker would not make ice..
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmmeter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
19 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Judy from Lenzburg, IL
Parts Used:
WR57X10026
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench (Adjustable)
Ice Maker stopped producing ice
I determined that the icemaker was not getting any water to the unit. The icemaker was still cycling but was not filling with water. I assumed the water valve was malfunctioning so I looked up the schematic drawing on the site and ordered the Water Valve & Bracket Assembly. It arrived within days. It took less than 10 minutes to install with miniumal effort. Within minutes the water could be heard flowing into the unit. Within an hour we had ice again!!!!!!!!!!!!!!!!!!!!!!!!
17 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mohammad from fremont, CA
Parts Used:
WR57X10023
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
The water was leaking from below the refrigerator, and a big puddle was being formed.
First I removed the screws, and the covering at the bottom rear of the GE Fridge. I then removed the existing water valve which was the source of water leak, it was all corroded with the leak at the valve joints, so I knew the water valve needed to be replaced. The water valve I received from PartSelect fitted in perfectly, once I had removed the old valve. All I needed was couple of screw drivers for the replacement. I would like to thank PartSelect for making this easy and saving me lots of money & time by not going for outside professional help.
16 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
CHRIS from LAGUNA NIGUEL, CA
Parts Used:
WR60X187
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Compressor overheating - Fridge not Cooling
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
D from ZELLWOOD, FL
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
15 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Kingwood, TX
Parts Used:
WR60X30349
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Motor rattled loudly
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from Simi Valley, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lowell H from Gilbert, AZ
Parts Used:
WR2X8702
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Water and Ice acuator had a hole in it. Need to be replaced.
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cristina from Los Angeles, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!