- Customer:
- DALE from OLATHE, KS
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ice machine trap door not opening or closing
Fairly simple fix. You must first uplug refrigerator, then take off the inside freeze door panel, approx. 25 screws. Then you must take out the trap door assembly approx. 6 six screws. Pop off the LED panel, requires the use of a flat blade screw driver to pop it off. Remove solenold by removing 3 screws, replace with new solenold.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from COLUMBIA, SC
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carl from SAN MARCOS, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker Leaking
Researched on internet/you tube; ordered part, and did the repair. Easy to do and saved the cost of a service call.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- james from apex, NC
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
replaced the ice flap solenoid
I followed the instructions posted by previous custmers and they were accurate and simple
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from HOSCHTON, GA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frost collected in the ice dispenser shute clogging it
Replace the flapper and this solved it. The video provided was excellent and allowed me to do this repair myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Howard from Shelby Twp., MI
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Flap to ice dispenser would not close
I followed the video provided, and followed the advice of bill from cleveland hts. ohio, and did not have to remove the trim to access everything. The video made it so simple, a monkey could have learned how in 5 minutes. Thank you very much for all the help on this website. I will recommend it to all.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Colin from Saint Helena Island, SC
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Bad Solenoid Not Closing Ice Dispenser Door
Followed the on line video. Clear, concise & easy. Thanks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- salomon from dallas, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers
flapper gaskeet dried out
The video to replace the flapper looks easy, howerer the first step is to remove thestic cover of the icemaker. In my refrigerator model (as oposed to teh one shown n teh video) teh coved if firmly attached and goes under the refrigerator external plate so I was never abel to take it oot (so step 1 failed).
I was able to replace the flapper TROUGH the whole whre te ice comes from! this took lots of patients and someone with small hands!
I was able to replace the flapper TROUGH the whole whre te ice comes from! this took lots of patients and someone with small hands!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Bradenton, FL
- Parts Used:
- WR62X10055, WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
icemaker door wouldn't close properly
Removed front panel and control touch pad to access solenoid and door recess assembly.
Replaced solenoid and door recess assembly. Didn't need spring and crank door.
Wish you could have supplied new screws, as the original are very corroded and I can't find them atv any hardware store.
Thanks
Replaced solenoid and door recess assembly. Didn't need spring and crank door.
Wish you could have supplied new screws, as the original are very corroded and I can't find them atv any hardware store.
Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Julia from Clearwater Beach, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
frost formed around ice maker dispensser due to the flap not closing properly, the solenoid needed replacing
no instructions came with the part so I wrote for help from your techs. They were able to tell me how to access the solenoid. From there I was able to figure the rest out. I had to remove the trim, electrical board, flap, springs and arm to reach the screws necessary to remove the solenoid. I removed some of the corrosion with a baking soda paste so I could remove the screws. I carefully noted each step and position of the parts I removed and reversed the process to put things back after replacing the solenoid.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vonda from Hendersonville, TN
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
The Ice dispenser tube in the door would accumulate ice
We followed the instructions we found on this site.
First we unplugged the refrigerator.
Then we removed the control panel that has the ice type selection on it by releasing the three spring latches. These are accessible from the bottom of the panel looking up toward the ice dispenser. There are three holes. Press a narrow screwdriver or punch in each of these holes and then pull out the control panel. (Be careful not to disconnect the wires, but observe how the wires are routed.)
Then we removed the ice tube cover that covers the solenoid assembly. There were four screws. One was very rusty and it required some WD40 to loosen it. Once the cover was removed the solenoid was visible on the right. (It has a floating component that attaches to the "arm" of the flap. This is how the solenoid opens and closes the flap. The flap needs to close properly so ice does not build up in the door.)
There were three screws that had to be removed to get the solenoid out. (The top one you may just need to loosen once the bottom two are removed.) When the solenoid was removed we also removed the old floating component from the flap are and replace it with the new one. We slid this into the solenoid hole and then screw it in with the three screws.
Before we attached everything, we plugged in the refrigerator to test the solenoid. We dispensed some ice and waited to hear the flap close. (The flap close is slightly delayed so be patient.)
We attached the cover that was over the solenoid being careful to route the wires as they were when we started. We test the solenoid again. Then we snapped the control panel back into place and tested again.
We found that having the right size screwdriver made a difference especially dealing with rusty screws. It was also handy to have a good flashlight. Having extra hands was helpful to hold the control panel and cover while working on the solenoid and routing the wires.
First we unplugged the refrigerator.
Then we removed the control panel that has the ice type selection on it by releasing the three spring latches. These are accessible from the bottom of the panel looking up toward the ice dispenser. There are three holes. Press a narrow screwdriver or punch in each of these holes and then pull out the control panel. (Be careful not to disconnect the wires, but observe how the wires are routed.)
Then we removed the ice tube cover that covers the solenoid assembly. There were four screws. One was very rusty and it required some WD40 to loosen it. Once the cover was removed the solenoid was visible on the right. (It has a floating component that attaches to the "arm" of the flap. This is how the solenoid opens and closes the flap. The flap needs to close properly so ice does not build up in the door.)
There were three screws that had to be removed to get the solenoid out. (The top one you may just need to loosen once the bottom two are removed.) When the solenoid was removed we also removed the old floating component from the flap are and replace it with the new one. We slid this into the solenoid hole and then screw it in with the three screws.
Before we attached everything, we plugged in the refrigerator to test the solenoid. We dispensed some ice and waited to hear the flap close. (The flap close is slightly delayed so be patient.)
We attached the cover that was over the solenoid being careful to route the wires as they were when we started. We test the solenoid again. Then we snapped the control panel back into place and tested again.
We found that having the right size screwdriver made a difference especially dealing with rusty screws. It was also handy to have a good flashlight. Having extra hands was helpful to hold the control panel and cover while working on the solenoid and routing the wires.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Clifford from Goose Creek, SC
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Sticky ice maker chute door
The model we have, the front panel snaps into place. It was removed for access and the electrical connectors unplugged. Four screws and the chute assembly was removed. Removing three screws and opening the chute door allowed the solenoid assembly to be removed without removing the door assembly. All parts and area were cleaned and the assemmbly was the process in reverse.
Guideline to prolong recurrance: always put ice into glass first to reduce splashing of ice falling into liquids causing the solenoid armature to rust and stick.
Guideline to prolong recurrance: always put ice into glass first to reduce splashing of ice falling into liquids causing the solenoid armature to rust and stick.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Warren from Merrimack, NH
- Parts Used:
- WR62X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Ice dispenser door not closing after dispensing ice
First remove trim surrounding ice/water dispenser assembly. Use a flat spackle knife to obtain space between door and trim. Be careful not t scratch refrigerator door. Then pry trim off. This was the most difficult part of repair. The front plate of the dispenser is held to the back of the dispenser by two friction fastners and in the case of my refrigerator a phillips screw (some don't have screw in middle). Use a small round tool like an allen wrench to push up on the 2 fastners to release them. Next push the front assembley aside and remove the 4 screws holding the back part of the dispenser. Push that assembly aside. Remove the defective solenoid assembly by removing the 3 mounting screws. The solenoid base can be worked out by slipping it out of the solenoid assembly plunger still attached to the dispenser door assembly. Next slide the plunger off of the dispenser door assembly. Install new solenoid assembly by reversing this procedure.
Hint - I found the ice door assembly (wr17x11653) also needed replacement and it is well worth the effort to replace both at the same time.
Hint - I found the ice door assembly (wr17x11653) also needed replacement and it is well worth the effort to replace both at the same time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jabe from Little Torch Key, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
In-Door Dispenser Didn't Work And Leaked Water
1. Use skewer to press plastic tabs under control panel, 2. Remove control panel and unplug solenoid, 3. Unscrew dispenser assembly and solenoid screws, 4. Press in tabs on lamp and remove assembly - unplug, 5. Replace lamp assembly, 6. Replace solenoid assembly and fasten screws, 7. Replace flapper. 8. Replace other parts in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Hillary from MONTCLAIR, NJ
- Parts Used:
- WR02X11330
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Leaking from connector every time water was used
I watched the instructional video on this website and did everything that it said. There is no more leak when I use the in door water. Was as easy as it looks in the video and I am very happy!
Was this instruction helpful to you?