TFT22JADAAA General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Mike from Lawrence, KS
- Parts Used:
- WR02X10140
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Produce side of the refridgerator was warm, freezer side cold.
removed the back of the freezer unit and replaced the defrost heater and thermastat. took the controls out of the produce side and replaced the defrost timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Itamar from SARASOTA, FL
- Parts Used:
- WR02X10140
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Replacing the Hinge Cam Riser (GE Part # WR02X10140) - it was brooken
I have just followed the instructions on the youtube video: It is really easy. I did. Thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Sarasota, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Open defrost heater
The most difficult part of the repair was the melting of the ice and preparation. I did change a single element heater for a dual element heater, which required a little manual flexing of the sub-frame, but it assembled with little issue. I was lucky, I did not have to splice the extended harness connection. Rerouting my existing gave sufficent length.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Middleville, MI
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
refrigerator not cold
I called the repair tech who obviously did not want to come out, thank god. He told me to remove the back panel of the freezer and also check fan on back side. Told him there was alot of ice on freezer condenser and he advised that defrost heater was probably shot, and referred me to partselect.com. I unplugged the frig/freezerer, and removed the heater and saw it was blackened and cooked. I used a hairdryer to thaw the condenser, and the new part arrived the next day. I reattached the 2 plugs, 2 screws, and put the back panel of the freezer back on. I plugged the appliance back in, checked it 6 hours later and the frig is cold again. It was a VERY easy repair and took less than 30 minutes from start to finish. I was quoted between $40-$78 for the part at 3 different places in the phone book, which would have also required a 45 minute drive. I got it here for $38 including shipping and it arrived in 24 hours !
With the "blow-up view" appliance feature on this web-site, and simply being guided to the correct part by entering the model number, it was a very easy ordering process and repair.
With the "blow-up view" appliance feature on this web-site, and simply being guided to the correct part by entering the model number, it was a very easy ordering process and repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Longs, SC
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer building up Ice
This is such an easy fix!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ronald from palmyra, VA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
freezer freezing and fresh food compartment not cooling
i unplugged the fridge, first i removed the racks, then unhooked the grounding clip. the i tool off two 1/4 nut screws holding the backplate. then i used my wifes hair dryer to thaw out the ice. after it thawed out i unscrewed the element bracket which is secured by two philips screw. after taking the screws off, its just unplug one end at a time and plug it to the new one to avoid confusion. then reverse install to put back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Schenectady, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
No Defrost - Top of freezer thawing
By the time this failure (failed defroster heating element) is evident (top of freezer starts thawing), the entire freezer coil is encased in a block of ice & frost is visble on the back freezer panel.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GARY from SPRAGGS, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ran All The Time Did Not Freeze.
Removed cover in freezer over evaporator,unbolted element ,plugged ,and replaced, very simple. Should be first thing checked when theres a problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patricia from Naples, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Refrigerator would not cool
I followed the easy instructions included with the replacement part I ordered. I removed the back of the freezer, unpluged the broken heater and replace with the new heater. The heater just plugged in, very very simple. I put the back panel bach on with the two screws and it perfectly. Not back for a girl!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- carol from Du Bois, IL
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Defroster quit working. The freezer would frost up and not cool the fridge or freezer properly.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires.Threw away the old defroster. Put the new one in. I had to reroute the blue wire over to the right hand side and plugged it in.Put the back on. put the shelves in and I was done! We had this done just about 3 years ago and it cost us about $175. The cost of this repair was only $38.05 with shipping and all! What a great deal! Thanks so much PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alex from Madisonville, KY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Refrigerator stopped cooling, back panel freezing, not defrosting
The repair itself is super easy. The heater harness comes with instructions that is easy to follow. The only issue I encountered is that my refrigerator had 1 heating element and you will get one with 2 heating elements. Because of this, the new connectors are on 1 side. Since my old heater had 1 connector on each end, 1 wire is too short if you route both wires the same way as before. The kit comes with an extra wire and directs you to splice the short wire and attach the extra wire with the included connector. I figured a refrigerator with a spliced wire is not a good combination so I rerouted the short wire to the other side along with the other wire. This allowed me to connect both wires without using the extra wire.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Melvin from Linesville, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator side of refrigerator/freezer wouldn't stay cool. Ice jam in cooling cools (due to burned out defrost heater) prevented proper air flow.
Removed shelves and light bulb cover. Then removed the two screws that hold the back wall of freezer compartment in place and removed cover. Thawed ice jam with hair dryer. Removed the two screws holding heating element in place and pulled element out far enough to disconnect the two wires. Reconnected wires to new element and put everything back together.
Installation instructions which came with new part were accurate and very easy to understand.
It took about 30 minutes total.
Installation instructions which came with new part were accurate and very easy to understand.
It took about 30 minutes total.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Orient, OH
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frig AND freezer side not cooling
This is a repair INSIDE the freezer. Turned off unit.. Unplugged. Removed shelving on freezer side. Removed freezer draw rails (4 screws total.) Removed 2 screws that hold rear panel in place at rear of freezer side (this is inside the freezer). Carefully removed metal panel by pulling from the left (side that does not have shelving clips. As noted on this website and other users, the freezer coils were incased in ice. Thawed with a hair dryer (put towels in bottom of freezer-ice was pretty heavy in mine). When thawed, remove heater element by removing 2 screws that hold it to the aluminum bracket. Then remove wires on each end. Simply install the new emelment by attaching wires back on heater and screw new unit in place. (My original heating element was a single element-you could very easily see where the heating coil inside the glass tube had shorted out. My replacement heater was a 2 element unit. This did not pose any problem at all-installs in the same manner-good directions are provided.). Replace all parts in reverse order. It's that simple. Saved probably $150. This site is wonderful! Fast shipping and the users install tips/notes are fantastic!! Will shop here again if I have to (have a Maytag washer that isn't draining and going into spin-bet the fix is on here somewhere!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- charles from leicester, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
the top of freezer was warm and also refrigerator
I removed food, then removed shelves.
The light bulb and shade had to be taken out.
removed two screws from interior back panel.
defrosted cooling coils
removed two screws from defrost heater
took off two wires ...done
reversed procedure to finish installation
The light bulb and shade had to be taken out.
removed two screws from interior back panel.
defrosted cooling coils
removed two screws from defrost heater
took off two wires ...done
reversed procedure to finish installation
Was this instruction helpful to you?
Thank you for voting!