TFT22PRDAWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Kenneth from Sweet Home, OR
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
evaporator coils iced up causing no cooling in freezer or fridge.
First I disconnected the Power from the unit. Pulled out the freezer drawers and the ice machine used a 1/4 inch nut driver and removed the sheet metal from the back of the freezer exposing the evaporator coils. I defrosted the coils. Then I removed the two screws holding the defrost heater braket assembly and removed the two electrical connections from it. I then installed the new heater put everything back together(reverse of installation)and it works like a brand new fridge and freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from Crown Point, IN
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refrigerator light wouldn't come on.
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Federal Way, AL
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Difficulty in removing the old switch
The old switch was hard to remove. Thinking that I may have to loosen the wires I used a socket wrench to remove a clamp. This was unnecessary. In the end the switch did come out using a large size screwdriver. The problem was that the expanding plastic tongue is not visible from the ouside so you have to try to feel your way around. If i had ordered the replacement before and not afterwards I would have seen this before hand.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from San Marcos, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Ashford, CT
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Cold water dispencing was becoming slower and volume of ice was becoming less.
Shut water supply off, removed power plug from wall and removed electrical connector from valve. Unscrewed two plastic nuts which retained lines to old valve. Remove old valve and reinstalled new valve with one screw. Removed inserts from end of lines. (These inserts keep lines from deforming.). Trimmed and chamfered ends of lines reinstalled inserts and installed lines to new valve. Turned on watter, checked for leaks turned power on inserted glass for water received good flow. Ice maker did not receive water. Due to low flow of water to ice tray because of low flow with old valve, ice built up in flexable water delivery tube that goes from back of refrigator to ice tray. Removed tube ran under warm water removed ice blockage reinstall tube all working excelent. This iceing problem took about anouther 15 to 25 min to correct.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Elk Grove, CA
- Parts Used:
- WR13X10020
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
cam closing washer broken
I propped up the door with 2x4 and shims to be level with the freezer door. Then removed the 2 screws holding the hinge to the main unit. Then removed the 2 screws holding the cam washer to the door.
Replacement was the reverse of disassembly. Be sure to tighten screws almost tight until both pieces are located correctly then fully tighten. Lift up refrigerator door slightly to remove shims and wood block.
I did the replacement myself but was nervous that the door would fall off the block and shims. I recommend having another person hold the door closed during the process.
Replacement was the reverse of disassembly. Be sure to tighten screws almost tight until both pieces are located correctly then fully tighten. Lift up refrigerator door slightly to remove shims and wood block.
I did the replacement myself but was nervous that the door would fall off the block and shims. I recommend having another person hold the door closed during the process.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from PLYMOUTH, MA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Ice maker needed replacement
Unplug refridge then loosened two bolts holding old ice maker. Lower then unplug and removed. Plugged in new harness and tightened two bolts to secure new ice maker. Plug in frig and wait for ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Laurence from Dearborn, MI
- Parts Used:
- WR13X10020
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Door would not close properly
I emptied everything from door compartments.I removed the top cover of the door pivot with a phillips screwdriver. I removed the two screws that that hold the pivot bracket with a 8 mm socket. Lift the door off the bottom pivot bracket. Remove the old bottom pivot bracket with an 8mm socket and replace it with the new cam bushings.You must replace both bushings on the bottom of the door and on the bracket that mounts to the base of the body of the refrigerator. Reinstall the door and screws .The doors should be level with each other if they are installed properly.If not check the freezer door .The bushings may be worn on that door also.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Coto de Caza, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Interior Light did not go on due to faulty switch
I ordered two switches, replaced both with a knife in 10 minutes. Interior light works, thanks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- HUAHUI from NEW HYDE PARK, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator cannot generate cool air
I bought the GE Refrigerator about 4 years ago for about $1500. The defrost Heater failed about one year ago. Then I called local repair guy, he replaced the Defrost Heater and charged me about $250. Now it happened again. I think we should try it to fix it by myself. I found the parts from partselect.com, it costs me $50 with 2-3 days shipping. After it replaced, it works fine again.
Note: Symtom: cannot make cool air, Frozen area with frost on the wall. Regeriator "leaking water" on floor since iced food started to melt...
Solution: open the cover of the wall inside of frozen zone, use hot water to defrost it gradually. removed the failed Defrost Heater and replaced it with new one.
Note: after you defrost the area inside of the wall, your refrigerator will work normally without the Defrost heater without any issue about week while you are waiting for the parts coming.
Note: Symtom: cannot make cool air, Frozen area with frost on the wall. Regeriator "leaking water" on floor since iced food started to melt...
Solution: open the cover of the wall inside of frozen zone, use hot water to defrost it gradually. removed the failed Defrost Heater and replaced it with new one.
Note: after you defrost the area inside of the wall, your refrigerator will work normally without the Defrost heater without any issue about week while you are waiting for the parts coming.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from SAN ANTONIO, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker filled too full and ice froze in the basket and a piece was broke on the icemaker itself.f
My son did it , and showed me what he did when he was finished.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marie from Elk Grove Village, IL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
My ice breaker started leaking and making noise anf the stripper broke.
I ended up needing to order a new ice maker because the one I had is discontinued. I'm a 65yr old grandma and I did it myself!!!! The hardest part was finding the tool to loosed the nuts. I took the old one out and just put the new one right in it's place. Easy as pie.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frank from Florham Park, NJ
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench set
Water was not running out of dispenser but the ice cube maker was working
Well I Googled the problem to the dual inlet water valve. Luckily I found PartSelect for the correct part and the installation was simple. I now have both the cubes and water working properly from the dispense.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from CRIDERSVILLE, OH
- Parts Used:
- WR51X10031
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Automatic Defroster was not working and it caused the unit to not stay cool.
After removing the 4 screws from the inside back panel of the freezer and setting a small heater with fan, on a small metal step ladder for about twenty minutes to defrost the freezer coils, it was a snap to remove the two small screws holding the burned out heater harness defrost assembly, and unplugging the wire harnesses to replace the burnt unit with a new one. Actual hands on time was about 5 minutes. Difficulty level, well... my wife did it and she is not mechanically inclined.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lynn from MOUNTAIN HOME, ID
- Parts Used:
- WR30X10093
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Made ice would not eject from ice holder bin
removed broken bin , slid new ice bin in closed door. I bought the complete part.
Was this instruction helpful to you?
Thank you for voting!