Customer:
Gerald from San Clemente, CA
Parts Used:
WR55X10025, WR02X10552
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fridge too warm, evaporator icing up
After replacing the defrost heater, main board and thermistor I still had the same problem. Called a repair guy and he (with the help of GE on the phone) diagnosed that the temperature sensor was bad. So I ordered from partselect and installed it and it fixed the problem. Been good for a couple months (knocking on wood). To install I had to cut the 2 wires to the old sensor, crimp the 2 new wires on and snap the new sensor to the clip on the evaporator. Very easy. Make sure you seal the ends of the wire crimps so moisture doesn't get in and corrode the connection.
600 of 720 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Luis from College Station, TX
Parts Used:
WR60X31522
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Freezer Fan
I removed two srews from the back panel inside fthe reezer compartment and the two that hold the air manifold/baffle? and pulled the baffle out. Then, I removed the two srews that hold the front part of the fan bracket behind the baffle and the back panel came out easily. Two more screws and one quick connect plug attached to the fan and I was done with removal. Insallation was even quicker, I slid the original fan right off the old motor and slid it on the new motor's shaft. Piece of cake! Thanks Partselect.
253 of 276 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michele from North Smithfield, RI
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
my refigerator was warm but the freezer was cold and working correcttly
I went to a GE repair center to explain my problem, the service center reccomended that I have a techinician come out o look at it. $75.00 for the visit and what ever labor and materials wuld cost.

I went on line to see if there were others having this same problem and found that there were many with the same problem.

After reading some of the ways that people found out what was wrong ...it became a matter of three components, the timer, heater or thermostat.

I tried the most common component and the less expensive one first , the thermostat switch I installed it very easily snipping two wires and attaching the news using wire nuts I used the diagram on this website to pinpoint the component and there has not been a problem since.
269 of 338 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Menomonie, WI
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
refrigerator was getting too cold
I removed the old temperature sensor by cutting the wires. I attached the wires of the new sensor with wire nuts and mounted it in the same bracket.
142 of 197 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marty from West Bloomfield, MI
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench (Adjustable)
Internal water lines brittle, cracked, leaking
First of all, the larger white plastic tubes in this thing are 5/16" OD, which no plumbing store seems to stock. At the lower left rear end there are 2 tubes, one for water and one for ice, that are doomed to fail being in proximity of a heat source - they essentially get cooked to the point of becoming brittle and cracking. The smaller tube and union can be easily found, but do yourself a favor if the larger one cracks and order the plastic tube and water tube union here, and just cut off the brittle part and amend the old tube using the union.
118 of 136 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Matt from RPV, CA
Parts Used:
WR17X11440
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Small leak on water tank behind vegetable crisper
1. Turn-off water
2. Removed drawers and bottom three shelfs
3. Remove screw inside refrige that is holding the water tank in place
4. Remove bottom front grate on fridge (2 screws) and disconnect water line from quick disconnect (residual water will run out of line)
5. Remove bottom cover on back of fridge
6. Disconnect water line from quick disconnect on bottom left side when looking from the back of the fridge (residual water will run out of line)
7. Remove water tank from inside of fridge
8. Install new water tank - install screw that hold water tank in position
9. Route lines through hole and to the two locations you removed the old ones
10. Install both lines by pushing them all the way in the quick disconnects. Pull on them to make sure they are secure.
11. Turn on water and look for leaks
12. Reinstall bottom front grate (2 screws)
13. Reinstall back cover (5 or 6 screws)
14. Install shelfs and drawers inside fridge
115 of 130 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Greg from Windsor, WI
Parts Used:
WR55X10025, WR51X10055
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
freezer clod-fridge warm, coils were frosting up cutting off air flow
First unplug then remove all food and the ice cubes from the freezer only..Then removed the traysand then the 2 panel screws. Defrosted the coils with a hair dryer,removed the 2 screws holding the heater and then unplugged the wires from each side.Installed the new heater and now has been fine for 12 days now..The sensor- I just spliced it in the exact way the old sensor was wired.All seems fine so far. Was alot cheaper to buy the parts and install myself than to pay for 1 service call..
105 of 133 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Suwanee, GA
Parts Used:
WR60X10209
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Warm freezer and no ice
This story starts with a GE side-by-side refrigerator that has always had wide temperature swings and a temperamental water dispenser. The ice maker was not making ice, and the built in digital thermometer showed it was running warm. I suspected that the heat exchanger was full of dust and so looked there. What I found was that the condenser tank was hot to the touch and the fan wasn’t running. As an experiment, I aimed a fan at the it for a while I saw that the freezer temperature dropped back to normal.
.The fan is marked as 11.2 DC so I checked for voltage at the fan and found some. With three wires and no wiring diagram I wasn’t sure this answered all the questions, but hooking the fan to a 12 volt power supply didn’t get it to spin.
I priced parts at a couple websites before using partselect.com . They also have a good diagram to look at (Sears diagrams are really poor). I ordered the part with 2-day shipping; it arrived on time, was correct and fixed the problem.
94 of 124 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from Benicia, CA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple.
Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use.
The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap.
After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
89 of 122 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from West Bloomfield, MI
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker stopped working
I unplugged the electrical connection. Then I removed the 2 screws holding the icemaker in place. I lifted out the old icemaker unit and put the new one in place. Then put the 2 screws back in and plugged in the new unit.

The icemaker started making ice very soon after turning the unit on.
82 of 109 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laura Beth from Mandeville, LA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken ice maker part
used a screwdriver to remove screw and unplugged part. Plugged in new one and secured with a screw.
Simple
76 of 99 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ray from Bensalem, PA
Parts Used:
WR60X10209
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
fan not running
Removed rear and front grills,brushed and vacuumed area- probably caused the fan motor to fail- unplugged fan, removed fan,motor,and shroud in 1 piece, carefully slipped fan off motor shaft, unscrewed shroud and motor. assembled in reverse order. Frige is in tight area, .I'll now roll it out and clean often
74 of 102 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Turcotte's Housing Service, In from Newmarket, NH
Parts Used:
WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Recessed door on ice dispenser would stay open causing the freezer to frost up
I inserted the tip of a very small screwdriver from a eye glass repair kit into the three small holes under the panel near where the ice is dispensed. I never would have known about this simple procedure if it wasn't for the feedback you post from your parts cumtomers. Once I did this the front panel with the buttons on it poped off and it was just a matter of removing a few screws at that point. The wires from the new solenoid easily plugged into the board on the front panel. I would recommend changing the screws at the same time. The old one's worked but they were rusty. I feel the solenoid was my only problem but I changed all the parts in between the dispenser door and the solenoid just to be sure.
70 of 92 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lorinda from Dallas, TX
Parts Used:
WR23X23343
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
dropped something on the light switch and it broke off
we just pried out the old switch and pulled it out the rest of the way with a pair of needle nose pliers. Pulled off the wires on the broken switch and reattached to the new one and just slid/clicked it back into the hole.
57 of 63 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eddie from Freeport, NY
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Not cold & saw ice accumulated on freezer back panel
-Disconnect the power supply wire& turn temp control inside refrigerator to 0!
-15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!

-30 mins to drain all water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!

-Set both temp control knots to 5 & put back all the food!

-If no ice build up on the panel after 10 days & then the repair is good!
52 of 64 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the DSE25JGHKCWW