Customer:
Russ from Bella Vista, AR
Parts Used:
WR51X10101, WR50X10068, WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer would have ice blockage and eventually both sides would quit cooling. Starting with the refriidgerator side then the freezer side temp would eventually begin to rise all over the course of 2 to 3 days.
Unplugged the refrigerator and removed inside back panel from the freezer compartment and left doors open to allow all ice to thaw. I chose not to use a hair dryer and speed up the process as this could possibly cause more damage if not done with caution. After all ice was melted i took both screws from heat element assembly and followed the simple instructions that came with the new part. Since meters an i dont really work well together and since defrost thermostat and temp sensor were so inexpensive. I opted to purchase those as well in my initial order. They were as simple to replace as a lightbulb. Unscrew the wire nuts from existing sensors and screw wire nuts back on to the new sensors. Buy purchasing all three items at once i felt it just ensured the fiz was complete and the unit has been operating for 7 days like new. One thing i would pass on. If it is the heating element that is burned out, the glass tuve on mine was very black and charred looking. Also when you take it out of the assembly the element was actually in two pieces. Did something cause the element to stay on until it burned out or just old age i dont know. Again, for less than 20 bucks i purchased the additional parts that would seem most obvious to replace and i would recommebd the same. Part select saved us a lot of money not only in parts but in allowing someone with no considerable knowledge in this areato make repairs without hiring an expensive repairman.
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
xiaopeng from canton, MI
Parts Used:
WR51X10101
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
defrost heater burned out. Lots of ice in and ont he evaporator. Both breezer and refrigerator do not cool right.
Disconnected power. Removed evaporator cover in freezer. Removed the bad defrost heater. It is a glass tube about 10" long. The tube was black since the internal heater wire burned out. Use a hair dryer to melt ice in evaporator. Since there was excessive water coming from melt ice, I removed the back panel and took out the white plastic drain tube and collected water from the tube in a bucket. I put everything back and used the refrigerator for three days without problem, before the new heater arrived. Then I put on the new tube and everything was fine so far.
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Auburn, AL
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
14 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from bensalem, PA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken ice maker
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ernest W. from Charlotte, NC
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Ice maker Stripper lost a tooth
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the new stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David G from Walpole, MA
Parts Used:
WR17X11459
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
replacing ice maker drive dispensing cup
followed instructions already posted on your website, but had a very difficult time getting the dispensing side of the auger assembly to slide out, even after I disengaged the plastic tabs. There is no easy way or place to grab the assembly to pull it out. Finally turned the unit upside down and pounded on the edges of the assembly with a wood block and a small hammer. Once the part started coming out a couple of inches, I flipped over the ice bin and was able to pull it out the rest of the way, once I had something to grab on to. After the auger assembly was out the cup replacement was easy per posted instructions and the unit snapped back together easily.
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mike from Aguilar, CO
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Cape Canaveral, FL
Parts Used:
WR51X10101, WR50X10068
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
The Factory "Single" Defrost Element Was Burned Out.
Unplugged frig. Emptied freezer shelves of food, removed ice container, removed all shelves, removed light bulb cover and light bulb, removed rear panel over coils (2 phillips on bottom and 2 1/4" hex on top/staggered. Used hair dryer hung on a wire to defrost the "ice block" over the coils. Used heavy towels to catch the water in the bottom so the condensate drain didn't just overflow. Removed the 2 screws holding the old element. Unplugged the quick disconnects. The new 2 element heater purchased at partselect is not "encapsulated" like a florescent tube as was the original. Much greater efficiency with exposed element coils. Re-routed blue wire on left of coil bank to the right-used the same split insulator that pink wire is in to keep it safe, did not need to use the jumper extention that comes with the kit. Plugged in both the blue and pink wire quick disconnects, installed the new defrost element with the 2 screws. Cut the old thermostat right up against it's sensor pot. Stripped existing wires, used my own wire nuts to mate the new thermostat, wrapped tight with electrical tape, then tucked them up underneath. Snapped the new sensor on the evaporator line at original location. Replaced panel, plugged frig back in, turned control in frig side to 1, and it works like new now. No more freezer burn. Ice cubes better. Still, this design is poor and no more ge major appliances for me.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
EDWARD from INDIAN WELLS, CA
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Fresh food section lights were all out, but the bulbs tested good elsewhere.
I popped the switch out using the blade of a small screwdriver and noticed that it connected with two wires via a slide on connector for each one. I noted the info on the old switch to identify which wire went to which terminal. I held each wire with a pair of pliers while I pulled the wire connector off the terminal on the old switch. I connected the two wires to the correct terminals on the new swith, and popped the switch back into the door frame. Easy, easy, easy and saved the $40 service call + parts cost!
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GEORGE from ELIOT, ME
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Will not make ice
Bing , Bang, Boom.
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Graeme from Sarasota, FL
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Icemaker flap not closing, frosting up
Watched video, however could not get outer casing off. Under the panel are three small holes, pushed up with an Allen key, used a small screwdriver to wedge out, came out easily, followed instructions from video on removing and replacing solenoid
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tim from The Woodlands, TX
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ann from Provo, UT
Parts Used:
WR51X10101, WR50X10068, WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Refrigerator kept getting warm
I am a 45 year old woman who is pretty handy but with no prior knowledge about appliance repair. I do have the attitude that if someone else can do it, so can I, which is helpful. I was able to watch a video on this website that showed me exactly how to replace one of the three parts that I replaced. It totally made it easy so that I knew what to do with the wiring. So far, my side by side is working great. I'm the champion! This repair cost me about $75. Who knows how much a repair man would have charged just to look at it.
12 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jo Anne from Walnut, CA
Parts Used:
WR32X10156
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
glass panel cover/glass cracked
First, I removed the top drawer blocking the area where I needed to put the glass panel cover. Then, I removed the drawer along with the glass panel holder to which I needed to install the glass. I installed the glass to the panel holder without difficulties (although the glass cover was expensive :() and reinstall the drawers back to their proper place. This repair was actually a no-brainer.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Powell, TN
Parts Used:
WR71X10582
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
replace split shelf with solid one
The slideout shelf "assembly" comes without the
keeper tab, and as such is incomplete. You have to order it separately or rob it from the old one. If the old one is broken or you break it trying to get it out of the old one you're out of luck unless you ordered
the tab also. Other than that it's a no-brainer.
8 of 10 people found this instruction helpful.