PFCF1NJWC General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Peter M. from Lincoln Park, NJ
- Parts Used:
- WR02X10540
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Stewartsville, NJ
- Parts Used:
- WR57X33326, WR02X11330
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench set
water leak from water line and value housing
Unplugged unit. Removed back cover plate. Used 5/16 water line. Cut old broken line. Used water tube union and attached new line. Removed electrical contacts. Note very easy removeand replace the red and white hookups. Next remove water line at the old vale with1/2 wrench. Hook up water line to new valve. Icemaker line was not damaged so I removed from old valve and trimmed the end. Really installed line to valve. Plugged in fridge and turned water supply back on. Check for leaks. Had trouble locatingthe 5/16 water line but found bulk. PARTS SELECT had the guest connector and the replacement valve. I received the correct parts and saved me $$$$. Plus my wife happy right before the holidays! !!,
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gregory from The Villages, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
Water dispenser inoperative
Replaced Double Outlet Water Valve then defrosted coiled plastic water tubing at bottom position inside refrigerator into pan of hot water for 10 minutes. Water still did not flow. Defrosted refrigerator and water dispenser immediately resumed operation. Suggestion -
defrost refrigerator first.
defrost refrigerator first.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paypal_shipping_address from Ripon, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from MATTHEWS, NC
- Parts Used:
- WR14X10238
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Frayed door gasket
Removed old worn out gasket and installed new gasket
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gratnie from Newport News, VA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Water dispenser would not stop leaking on the unit.
First, turn off main water valve. Then, at the rear of refrigerator remove the rear panel exposing the water valve assembly. Cautiously, proceed by disconnecting the water hose and electrical connections. To complete the task, just worked in the reverse steps to exchange the faulty equipment.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Glendale Heights, IL
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Light would stay on when door closed
Extremely easy repair, the hardest part was getting the old switch out. I used a pair of needle nose pliers to squeeze the tabs in and it came right out.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alan from Ruther Glen, VA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench set
My water hose broke, the valve is 1 use.
1. remove back shield of fridge.
2. unscrew old valve.
3. remove electrical connections.
4. remove white inserts on new valve.
5. cut feed hoses next to old valve.
6. place white inserts on hoses.
7 insert hoses into recepticals on new valve.
8 shut off water supply to fridge.
9. remove water suply line from old valve.
10. attach water supply line to new valve.
11. connect electrical connections.
12. bolt valve back on to fridge
13. turn on water supply to fridge
14. test both ice maker and water dispensor
15. replace back shield to fridge
2. unscrew old valve.
3. remove electrical connections.
4. remove white inserts on new valve.
5. cut feed hoses next to old valve.
6. place white inserts on hoses.
7 insert hoses into recepticals on new valve.
8 shut off water supply to fridge.
9. remove water suply line from old valve.
10. attach water supply line to new valve.
11. connect electrical connections.
12. bolt valve back on to fridge
13. turn on water supply to fridge
14. test both ice maker and water dispensor
15. replace back shield to fridge
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from Warrenton, VA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set, Wrench set
Water was leaking from the cracked plastic valve
1 unplug fridge
2 turn off supply line for ice maker
2 remove lower back panel of fridge
3 disconnect in and out line from valve
4 remove valve (one screw.)
5 disconnect power line to valve.
reverse to reinstall. Very easy.
This valve is a cheap, poor design. This is the second one in 5 years. I replaced the first one because the line in the freezer would "drip" creating an ice dam so the ice maker wouldn't work. This time, the water dispenser on the front of the fridge has been dripping for months - finally the valve just dissolved and was spraying water all over the floor. It ran down into the basement. Keep a eye out if you have a GE fridge.
2 turn off supply line for ice maker
2 remove lower back panel of fridge
3 disconnect in and out line from valve
4 remove valve (one screw.)
5 disconnect power line to valve.
reverse to reinstall. Very easy.
This valve is a cheap, poor design. This is the second one in 5 years. I replaced the first one because the line in the freezer would "drip" creating an ice dam so the ice maker wouldn't work. This time, the water dispenser on the front of the fridge has been dripping for months - finally the valve just dissolved and was spraying water all over the floor. It ran down into the basement. Keep a eye out if you have a GE fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from BOZEMAN, MT
- Parts Used:
- WR02X12008, WR02X10540
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Noisy Freezer Evaporator
Find a video on youtube. Remove 6 screws. Pull the Styrofoam part up before removing the panel. Unplug and Remove the fan assembly.
You will need a NUT DRIVER to take the bracket off the backing plate.
I ordered the red grommet and the red bumper. You need TWO of the red grommets if that is the problem. My freezer was about 8 years old, and the grommets were worn and compressed, the bumper was not. Replacing these parts DID NOT FIX the problem. I needed a new motor.
I probably disassembled and reassembled this stuff about 7 times before I got all the parts and tools. Each time I had to unload the freezer.
You will need a NUT DRIVER to take the bracket off the backing plate.
I ordered the red grommet and the red bumper. You need TWO of the red grommets if that is the problem. My freezer was about 8 years old, and the grommets were worn and compressed, the bumper was not. Replacing these parts DID NOT FIX the problem. I needed a new motor.
I probably disassembled and reassembled this stuff about 7 times before I got all the parts and tools. Each time I had to unload the freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lary J from Destrehan, LA
- Parts Used:
- WR02X11330
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Plugged water line reservoir
Turned water supply off; pressed dispenser sw to release presure ; cut tubing holding reservoir ; nuit driver to release screw holding reservoir and pulled out ; took outside and used hose nozzle to try to clear; did not clear at first then took weedeater string and disloged something and water flowed freely; turned out had to change waer solenoid valve (both) as the one for the water dispener was also plugged which did not show up before.
P.S. Had back flow water thru system before and changes of parts. Water flowed freely.
P.S. Had back flow water thru system before and changes of parts. Water flowed freely.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Loren from EL PASO, TX
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
40 year old refrigerator brittle light switch fell apart
with a jewelry screwdriver I pried the lock tab in and pulled switch down carefully, the hardest part was that the power wire connector was stuck on good but the pliers and the jewelry screwdriver was its match for a bout 5 minute for one connection a simple pull off prong connection. After the wire connected back to switch it popped back in SNAPP
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from EAST JORDAN, MI
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Light went out in refrigerator
Pop out switch, pull wires, attach wires to new switch and pop back in. Easy smeasy!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sumlorq from Cleveland, OH
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light switch freezer door
put the gratefruit knife behind the old switch pooped it out pluged the new one in piece of cake 5min.even vacumed the dust off the coil
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from KNOXVILLE, TN
- Parts Used:
- WR60X30922
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice built up around evaporator fan blades and blades chipped and broke. Refrigerator was making loud vibrating noises.
Removed ice bucket, and unplugged ice maker. Removed light cover. Removed ice maker. Pulled fan blades straight up and removed. Pushed new blades on to motor shaft. Fairly easy .
Was this instruction helpful to you?