John from Windham, NH
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers, Socket set
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
23 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leonard from Keller, TX
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Main circuit board wouldn't allow the compressor to come on
Removed old circuit board and replaced with new
22 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
joe from spartanburg, SC
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Light would not work when I opened door.
I lifted the old switch with a flat screwdriver, attached wires, and popped into place. Saved 80 bucks for a repair call.
23 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from The Villages, FL
Parts Used:
WR17X11168
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Tube feeding ice maker leaking.
Moved refrigerator out from wall. On the back of the refrigerator at the bottom there is a metal plate. Removed this plate with a socket wrench to expose where the end of the tube pluged in. The grommet securing the tube, white on my unit, had to be pushed up to release the old tube. I pushed the new tube into where the old one was and it self secured the tube. The other end of the grommet I pushed through the hole feeding the ice maker,first pushing out the broked part with a screwdriver,and securing that end with the attached sticky tape already attached to the grommet. I cleaned the area around the hole with alcohol before attaching the grommet.Replaced metal plate and done. No leaks.
23 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Luci from Richvale, CA
Parts Used:
WR71X10973, WR71X10979, WR71X10764
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
We Needed more food storage space.
We noticed that there was door area that could be used - so I went hunting for more shlves - Thank Yo for having them in stock....This is used for a Care Home for Multi-Handicapped ladies and their staff....Much appreciated!
24 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Craig from Soldotna, AK
Parts Used:
WR07X10057
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Compressor does not run
The first component I suspect is the relay mounted near the compressor. I installed the replacement relay and still nothing. I then removed the control board, inspected it for burnt circuit paths or components. I noticed the c.b. relay for the compressor's lead had burned away the solder and there was no longer a viable connection. Not sure why this happened but my next step is to a) reestablish a solder connection. If this fails then b) replace the control board.
26 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carlos from Whittier, CA
Parts Used:
WR17X11168
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
water leaking from grommet tube assembly at back of fridge
After thawing out freezer pushed water supply tube out from inside freezer diconneted the supply line from the valve assembly by pushing in the bushing with my finger and inserting the new line. Sadly that wasn't the problem!For anyone with the same symptoms of ice building up on your ice maker, to the point where it clogged the water supply line and started leaking from the grommet assembly. The problem is the valve not closing when the ice maker does not need any water. so I ordered a new valve and hopefully that will fix my problem.
22 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Glendale, AZ
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
21 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from Abington, MA
Parts Used:
WR60X10205, WR60X10185
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
The evap fan burnt out again (after 2 yrs)
I had to remove the contents of the freezer, and remove the fan covers ( 2 screws) and the back of the freezer. I pulled out the evap motor assembly, removed the motor from that and re-installed the new motor into the assembly, (2 screws). Installed the evap assembly back into the freezer, ( another 2 screws), making sure to plug the motor into the wire harness and keeping the wires away from the fan blades. Then installed the back of the freezer (2 screws...again) and put on the 2 plastic pieces that completes the freezer assembly. I plugged the refrigerator back in and heard the fan start and knew everything was going to work fine
21 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
justin from brownsville, OH
Parts Used:
WR49X10091
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
evertthing in frige was freezing
went online to an appliance repair site and found out that this model has problems with the damper malfunctioning. went to partselect and ordered what I needed and it arrived in two days. to replace the damper you just remove the light at the top of the frige and the cover around it . the damper assembly only has 2 screws and is easy to remove.
19 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tracy from Yuba City, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Herbert from Sunriver, OR
Parts Used:
WR55X10942C, WR49X10091
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Frozen water filter and food in fresh food side
Initial diagnosis indicated faulty cold air damper, so first action was to remove the light assembly and then the plastic housing that contains the FF fan and damper. The two hidden screws at base of housing required removal of lower decorative plastic duct that turned to be held by snap in-tabs at top and slide away fastener at bottom. The damper housing is held to the roof of the FF chamber by two screws that were taken out to remove the light assembly.

When the plastic housing is pulled towards the front of the refrigerator, the multi-pin wire connector can be disconnected and the damper assembly easily removed.

Installation required need of a thin plate to seat a sponge rubber seal without damage, so I used a thin metal kitchen spatula. Nothing unexpected was encountered in reversing the disassembly process.

Although the new damper corrected the excessive cold situation, the temperature max-min span remained in excess of 15 degrees F, so the control panel was swapped in the small covered cavity located in the outside back of the refrigerator. A 1/4" nut driver and needle nose pliers were all the tools necessary for this operation.

Together the two replacement components have solved the frozen food problem and the over night max-min FF span is now 5 degrees or less.
16 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Meridian, MS
Parts Used:
WR17X11168
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
Icemaker supply hose leaking at freezer entrance
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
richard from cleburne, TX
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer freezing up
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
16 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jamison from Heltonville, IN
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Iced up Freezer compartment in SxS
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).

Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).

EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
15 of 18 people found this instruction helpful.