- Customer:
- Terry from Simi Valley, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- lk from carlsbad, CA
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Loud knocking noise with the evaporator fan
I had taken the noise long enough and wanted to get this repaired. I didn't want to pay a repair man hundreds of dollars to do it so i decided to do it myself. I went on to YouTube and found a few videos that showed me how easy it was to do (very helpful).
I wasn't so sure all that noise would come from the Evaporator Fan motor so i ordered it and took the chance. For the small cost, it was worth the try.
All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.
Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.
The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
I wasn't so sure all that noise would come from the Evaporator Fan motor so i ordered it and took the chance. For the small cost, it was worth the try.
All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.
Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.
The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leo from TWIN FALLS, ID
- Parts Used:
- 40A15
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barry from Phoenix, AZ
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice maker ot making ice
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Jupiter, FL
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- dwight from phoenix, AZ
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
slow water flow in dispenser
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gregory from El Dorado, AL
- Parts Used:
- WR50X10068, WR51X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Freezer temp too warm Refrigerator side too warm
Thanks to others who also gave some detailed instruction on repairs I was able to do the same. I have a GE Profile side by side refrigerator/freezer Model No. PSC25PSSCSS The first repair I did was to remove/replace freezer defrost thermostat sensor that is cliped to condenser tube I snipped the wires close to the thermostat and pulled it off the tube I stripped the ends of the wires and twisted the strands then placed a piece of heat shrink tube onto the wire pushing it away from the exposed wire then I soldered the two color coded wires together then I pulled the heat shrink over the conection and used a lighter to heat up the heat shrink until it sealed the conection repeating this on the othr wire as well. I then removed the Old defrost Heater element by removing to screws then I disconected the two wires by simply pulling the connector plugs off both ends of the heater element assembly. This fixed the freezer being too warm for a short time but it started getting warm again that's when I noticed the defrost fan was not working, when you have the door open to freezer push the door switch in you should hear the fan come to life and blow hard. The fan was replaced I had to remove everything to get to it it's pretty simple to do it just unplugs make sure you order the right fan though My fan comes with the Thermistor already integrated into the plug this makes it easier. This fixed the problem with both Freezer & Refrigerator The Temperatures returned to normal Freezer 0 degrees Refrigerator 37 degrees I also checked out the refrigerator side Condenser I noticed only that the Condensate pan was starting to rust so I will remove it and use some Muretic acid to clean it up and then spray it with some Cold Gavanize with Zinc you can get this spray paint at Home Depot it seals and prevents rust. Or you can order a new one for about $ 16 bucks but it will start rusting just like the old one did eventually if you do order a new Condensate Pan I suggest spraying it before you reinstall it so that it will not rust. Greg H. Eldorado, AR
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marion from Palm Coast, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refridgerator Freezer stoped making ice
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Silicone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Auburn, AL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Somers Point, NJ
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.
10 minutes total.
10 minutes total.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Elizabeth from Huntersville, NC
- Parts Used:
- WR71X38317
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken dairy door
Part arrived in 2 days and took about 15 seconds to install. Great!! No more broken eggs!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from bensalem, PA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken ice maker
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ernest W. from Charlotte, NC
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker Stripper lost a tooth
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the new stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from HAINES CITY, FL
- Parts Used:
- WR60X10185, WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Freezer intermittently thawing and refreezing.
Local repairman was called. He replaced the condenser fan motor as it had an intermittent noise several days before. Cost of the repair was 252.00. Two days later freezer was thawing again. He then came back again and said it was probably the evaporator fan and would replace it for 339. dollars or the mother board which he would replace for 500 dollars. He recommended replacing the unit. Since my unit was still in pristine looking condition I decided to do some further research. That is when I found your web site. After reviewing the possible causes on your site I ordered the defrost themostat and and all three thermistors.As a precaution I also ordered the evaporator fan and defrost heater and bracket Assembly. When the parts arrived I disconnected the power to the unit. Removed the shelves and lower pan. Removed the light shield and light bulb. Reovede the two screws holding the evaporator coil cover. This allowed access to the evaporator themostat. I then cut the wires from the old themostat and removed it from the coil. I then stripped the wires on the colored wires and also cut the wires on the new themostat and stripped those. Then using wire nuts I aatached the wires making sure they were properly color coded. Wrapped with electrical tape and attached the new thermostat to the evaporator coil. I then located the evaporator temperature sensor and removed it from the coil and removed the clip and placed it aside for use on the new sensor. I cut the wires and discarded old sensor. Stripped wires on the new sensor after determining the proper length and stripped the wires where the old one was removed and the using in line connectors I first crimped the wires on the new connector and the crimped both wires to the wires previously cut and stripped. Reinstalled the connector to the clip and clipped it back onto the evaporator coil. I then disconnected the wires attached to the defrost heater bracket assembly, located the two screws holding it to unit and removed it from the unit. I did a continuity check on it and it checked ok but was black so I replaced it as a precaution since I already had a new one. Hung the new unit onto the mounting bracket reinstalled the two mounting screws and reattached the two wires. Reinstalled the evaporator cover making sure to reattach the ground wire clip. Reinstalled screws and light cover and all shelves and pan. Reconneceted electrical power. Unit operated fine for a couple of days and then thawed again. I then retraced the steps removing what I had to remove to replace the evaporator fan motor and replaced it per the installation instructions on your site. The unit has now been operating for five days maintaining -8 degrees in the freezer and 37degrees in the refrigerator. I probably could have done a little more trouble shooting at the main board but didn't want to risk damaging that since I already had the parts I thought would fix the problem if it wasn't the main board. I only replaced the one temperature sensor so I will probably return the two I did not use. Thanks for your excellent "how to"videos.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from Daly City, CA
- Parts Used:
- WR50X10068, WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Freezer thaws on top, no fan running in freezer
REPLACING THE DEFROST HEATER & BRA:
1- Empty freezer.
2- Remove all shelves.
3- Remove white painted metal wall plate opposite
the freezer door. There are 2 phillips head screws
attaching it.
4- There may be ice build-up on the freezer coils,
thaw the ice using a hair dryer.
5- Remove the 2 phillips screws holding the
defrost heater to the freezer coil frame, at the
bottom of the frame.
6- Install the defrost heater to the frame.
7- Replace metal panel.
REPLACING THE DEFROST THERMOSTAT.
1-Perform steps 1-4 above.
2-Locate the thermostat at the top of the freezer
coil in the freezer.
3-Cut the wires connecting the thermostat.
4-Connect the new thermostat to the wires that
were connecting the old thermostat, connecting
the wire color to the same color wire.
Note: Connect the wires by using wire splices
available at radio shack. Use splices
sized for 20 guage wire, and wrap with
electrical tape to protect from moisture.
5- Replace metal panel.
1- Empty freezer.
2- Remove all shelves.
3- Remove white painted metal wall plate opposite
the freezer door. There are 2 phillips head screws
attaching it.
4- There may be ice build-up on the freezer coils,
thaw the ice using a hair dryer.
5- Remove the 2 phillips screws holding the
defrost heater to the freezer coil frame, at the
bottom of the frame.
6- Install the defrost heater to the frame.
7- Replace metal panel.
REPLACING THE DEFROST THERMOSTAT.
1-Perform steps 1-4 above.
2-Locate the thermostat at the top of the freezer
coil in the freezer.
3-Cut the wires connecting the thermostat.
4-Connect the new thermostat to the wires that
were connecting the old thermostat, connecting
the wire color to the same color wire.
Note: Connect the wires by using wire splices
available at radio shack. Use splices
sized for 20 guage wire, and wrap with
electrical tape to protect from moisture.
5- Replace metal panel.
Was this instruction helpful to you?
Thank you for voting!