GSH25IGRBBWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Daniel from Anderson, SC
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
I had a water leak (undiscovered) from under my refrig
After de-energized unit (by removing electical plug from outlet),I removed the rear panel at bottom of unit. I then removed the mounting screw to the water valve. I then disconnected the wiring assembly from the old unit. I then removed the water supply lines going to the icemaker and water filter. I then placed the water supply into the replacement water valve. plugged in wiring assembly to new unit and rehung water valve inside refrig. Turned water valve on at water supply to check for leaks, finding none I then replaced back panel on refridge and plugged in electrical cord and returned refrige to normal place in kitchen.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Dexter, MO
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water leaked constantly from water dispenser in door
Had to turn off water and remove back panel and with a few tools the part was off and the new part put on in less that 30 minutes!! Finding parts on your website were easily found.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ronald from kissimmee, FL
- Parts Used:
- WR60X10185
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Very high pitch whine. Not real loud but really annoying.
First I hired a repairman and he said that it was in the unit and would not be worth the expense to fix.
I started to research on the net and this was one possible source. ( evaporator fan). I had to take it apart to verify it. Then put it back together to use until the part came.
The next time went much faster as I did not have to take near as many screws out to access the fan motor. Very Happy to have it working fine again as a new relacement would cost $1200. Thanks much. Ron
I started to research on the net and this was one possible source. ( evaporator fan). I had to take it apart to verify it. Then put it back together to use until the part came.
The next time went much faster as I did not have to take near as many screws out to access the fan motor. Very Happy to have it working fine again as a new relacement would cost $1200. Thanks much. Ron
Was this instruction helpful to you?
Thank you for voting!
Both Slides Were Broken
I removed the shelf, unscrewed the slide rails and replaced them with new ones. I replaced the shelf, put the food back in and I was done. Thanks, john bowers
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jania from Novato, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Glendale, AZ
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephanie from Tampa, FL
- Parts Used:
- WR71X38317
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Dairy Door Cover had cracked
Repair took about 5 seconds. No directions necessary. Super easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tracy from Yuba City, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jamison from Heltonville, IN
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Iced up Freezer compartment in SxS
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- richard from cleburne, TX
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
freezer freezing up
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jason` from Colchester, CT
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from DOWS, IA
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Freezer Cold Refrigerator warm
The defrost heater failed. The coils frosted completely over so no airflow to the fridge. Step 1. Empty the freezer. Ice maker and top shelf can stay. Remove power, pull plug or open breaker. Step 2. Remove shelves and bottom food drawer. Step 3. Remove bottom food drawer rails. 2 phillips screws on each side. Step 4. Remove back panel, 2 screws at the top. Work panel out. Note there may be a green ground wire hook on it at the top. This will expose the heater and the cooling coils. The heater is at the bottom of the cooling coils and is the width of the coils. Step 5. There will be 2 wires, one on each end, and two phillips screws holding it in. Wires pull straight out. Note which way the heater is installed and remove the 2 screws. Step 6. Assemble in reverse order. Be very careful with the heater. It is in a glass tube and is very easy to break.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cristina from Los Angeles, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carlton from Chino, CA
- Parts Used:
- WR72X239
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
the left drawer slide rail was broken from years of use.
First I removed the vegetable drawer and glass shelf. I matched up the 'new' drawer slide rail next to the broken slide.
I then used a phillips head screwdriver to remove the 2 screws that held the slide in place.
After removing the broken slide rail, I installed the new rail, replaced the vegetable drawer and glass shelf. New item worked like a charm.
The drawer slide arrived really quick after my order was placed. Approx. 2 days after ordering the part, it was on my front door step.
I then used a phillips head screwdriver to remove the 2 screws that held the slide in place.
After removing the broken slide rail, I installed the new rail, replaced the vegetable drawer and glass shelf. New item worked like a charm.
The drawer slide arrived really quick after my order was placed. Approx. 2 days after ordering the part, it was on my front door step.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Simi Valley, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this instruction helpful to you?
Thank you for voting!