PCF23RGWB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Michael from Sylva, NC
- Parts Used:
- WR50X10068
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Ice cubes froze in the tray and frost was all underneath
I read stories from the website how others did it so I figured I would give it a try. I put all the frozen stuff in the refrigerator piled up. Took out the shelves. Took out 2 screws with a socket extension ( nut driver will work fine.) Remove the light bulb. lifted up on the back panel...it came right out. Saw the coils and on top the sensor. Took it off, cut the wires, spliced in the color coded new one ( pink to pink, orange to orange) Stuck it in the top coil in the original position and crossed my fingers! I put all the pieces back easily, restocked the freezer and waited. HOORAY!! My ice cubes are all separate and free. NO frost inside. A very easy fix for $20.
Note: If there is a large amount of ice build up on your coils a hair dryer works great. The drain is on the bottom anyway. Also , you may want to seal around the wire nuts to keep moisture out. I did
Note: If there is a large amount of ice build up on your coils a hair dryer works great. The drain is on the bottom anyway. Also , you may want to seal around the wire nuts to keep moisture out. I did
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- M Alan from Lebanon, TN
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker door didn't open and close properly
I removed the outer plate by sticking a very small screwdriver in the small holes at the bottom of the plate and pulling the plate toward me.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Phillip from Springfield, VA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Ice chute frosted up
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from WOONSOCKET, RI
- Parts Used:
- WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer coils were iced up,was not cold enough,suspected the heater was the culprit
I had looked at videos on you tube,it looked simple enough. I mostly do my own repairs so I gave it a shot. the job went well,if you do not fix things around the house don't try to do the repair,find a handyman in your neighborhood to help you out,cheaper than calling a refrigeration man. It is not that hard to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Susan from Clifton, VA
- Parts Used:
- WR32X26198
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken Drawer
All I had to do was slide it in. But that's not what made me so thrilled with your site. What won my devotion was your site's ease of use (I couldn't find what I was looking for on GE's site) and the promptness of delivery. I will certainly use you again and recommend your services to my friends!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from Anaheim, CA
- Parts Used:
- WR29X10085
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
piece broke off on stripper causing ice to jam
tab on right top, flat insert on left. Pull up, toward you and to the right. It pops off. No tools needed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kyle from LAPWAI, ID
- Parts Used:
- WR17X11168
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Wasn't making ice
1. I unplugged the refrigerator/ freezer
2. Turned off water supply
3. Removed the screws that held the cardboard skirt in place
4. Unplugged the water tube from the push connect
5. Removed the screws around the water inlet to the ice maker
6. Remove the water fill tube
7. Install new water fill tube and put all the screws and plates back where they go
2. Turned off water supply
3. Removed the screws that held the cardboard skirt in place
4. Unplugged the water tube from the push connect
5. Removed the screws around the water inlet to the ice maker
6. Remove the water fill tube
7. Install new water fill tube and put all the screws and plates back where they go
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from PEORIA, AZ
- Parts Used:
- WR12X10625
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
broken plastic freezer shelf front.
Emptyed shelf of food. Aligned new plastic front piece. Pressed front. Went right into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Shirley from DUBUQUE, IA
- Parts Used:
- WR17X22072
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
The water dispenser was very slow
I Googled G.E. refrigerator water dispenser slow
There was a UTube video where the guy described the issue I had. Plus step by step instructions on repairs. Sure enough, I had the same issue.
Repairs were simple.
Shut the water line off, removed water line , drained the water out, after loosing the water tube from the control valve, I pulled the valve out a little so I wouldn’t get water in the electrical connections. Pulled 2 screws out of the bracket where the lines go into the refrigerator. From the inside, I removed the water filter cover, removed the filter, 2 screws holding the filter head in place. Pulled lines and filter head out. The u-tube video was very good. 2 things I did different was I pulled the control valve out a little so the water wouldn’t get into the electrical connections. The other, I used a nut driver to remove and install the filter heads
There was a UTube video where the guy described the issue I had. Plus step by step instructions on repairs. Sure enough, I had the same issue.
Repairs were simple.
Shut the water line off, removed water line , drained the water out, after loosing the water tube from the control valve, I pulled the valve out a little so I wouldn’t get water in the electrical connections. Pulled 2 screws out of the bracket where the lines go into the refrigerator. From the inside, I removed the water filter cover, removed the filter, 2 screws holding the filter head in place. Pulled lines and filter head out. The u-tube video was very good. 2 things I did different was I pulled the control valve out a little so the water wouldn’t get into the electrical connections. The other, I used a nut driver to remove and install the filter heads
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Troutville, VA
- Parts Used:
- WR57X10070
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
No ice cubes, ice down the inside back of freezer, constant buzzing noise.
Followed instructions from an existing video on this site. This site is very helpful both with regard to diagnostics and then removal/installation of the failed part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leif from Jacksonville, FL
- Parts Used:
- WR17X11168
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Intake hose to ice maker broke
After shutting off the h2o, I unplugged the refrigerator. Using the nut driver, I removed the cardboard backing. Then I removed the fitting where the inlet line to the ice maker and pried the old tubing from the unit. I then undid the clasp about 1/2 way up the back and removed the section that went through the back to the ice maker.
I then reassembled everything and plugged in the refrigerator as well as turning on the water.
Keep in mind that because h2o and electricity are involved. MAKE SURE THERE ARE NO h2o LEAKS.
I then reassembled everything and plugged in the refrigerator as well as turning on the water.
Keep in mind that because h2o and electricity are involved. MAKE SURE THERE ARE NO h2o LEAKS.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from EL DORADO HLS, CA
- Parts Used:
- WR50X10068, WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
freezer frosting in back, refrigerator compartment warm
I followed the partselect videos for the temp sensor and defrost thermostat and the refrigerator has been working well for a about a week now. The refrigerator is old enough that I was just going to replace it. When I called the repair company I use, they said it would cost $200 to $300 for the repair, but I didn't want to put that money into an old refrigerator. I did a little research, found this site and figured it would be worth buying about $20 in parts and giving it a try. I have absolutely no experience working on refrigerators, but the videos were so easy to follow, everything went smoothly. The old thermostat was definitely broken when I checked it with a meter, so I'm pretty confident that the problem is fixed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Lawerence, MI
- Parts Used:
- WR17X11505
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice would fall after removing glass.
I took the ice drawer out and turned it upside down. Then removed two philips screws holding the drawer front on. Then with a small straight edge screwdriver pry out the sides to release the locking tabs and remove the auger and crusher assembly. Then on the end of the auger remove the e-clip, slide the auger out and remove the broken part of the crusher dispenser and replace with new. Easier than it sounds. Parts Select was great to deal with. Had my parts in two days.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Centennial, AL
- Parts Used:
- WR23X31507
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light switch broke when I dropped a jar of jam on it.
The three bulbs would then remain on, so I loosened them to keep them off. I didn't know that the cooling system also would stop when the door was open, so for two days only the side freezer was operational. When I discovered that, I hot glued the switch button off, while I searched for a replacement part. The replacement part was an exact duplicate. A simple prying out of the old switch - using a screwdriver, and the reconnection of the two wires connectors to the new part, and clicking back in place ... done. Seriously, it took two minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Sugar Hill, GA
- Parts Used:
- WR12X10625
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
broken handle
Handle just snaps on.
Was this instruction helpful to you?
Thank you for voting!