Models > PJE25PGTEFSV > Instructions

PJE25PGTEFSV General Electric Refrigerator - Instructions

Jump to:

All Instructions for the PJE25PGTEFSV
91 - 105 of 679
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Bart from Whitestone, NY
Parts Used:
WR62X10055, WR17X11655, WR02X11330
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Dispenser flap for ice not closing. no water from dispenser was coming out.
Water line 5/16inch was severed, under refrigerator. Used union connector to join line. Dispenser plate removed using allen key to unsnap plate ,from under the plate itself. Removed screws holding solenoid valve and removed the plug from circuit board connected to solenoid. Installed new solenoid valve. Put flapper back in place, and made sure spring on left side of flapper is reattached to the opening on the flapper. This corrected all problems. Caution, keep an eye on spring that it remains in place.
8 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
M Alan from Lebanon, TN
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker door didn't open and close properly
I removed the outer plate by sticking a very small screwdriver in the small holes at the bottom of the plate and pulling the plate toward me.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from Elkridge, MD
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Ice Flapper warped and clogged up the Ice Shoot
I bought a Flapper replacement part from Parts Select. I installed it following their very complete on-line video directions. Their complete and easy to follow directions made my job very easy, and the work was completed without any problems and just as good as if it were done by a professional repair person. I am proud of my work, it couldn't have been done without their video insructions. Also I got delivery of the part within two days of my order. I will alway look for Parts Select any time I need an applicance repaired. Thanks to Parts Select!
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from Miramar Beach, FL
Parts Used:
WR62X10055, WR01X37886
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Frost In Frezer Compartment Where Chute Meets Ice Cube Maker
Removed front panel (using small screw driver) by popping it out, disconnected wire from solenoid, removed solenoid which was rusted, 3 small philip head screws held it in place insereted new solenoid,connected wire snapped front panel back in. Clapper valve closes tightly and no frost in frezzer, saved my self a bunch of money.
10 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Phillip from Springfield, VA
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Ice chute frosted up
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from Anaheim, CA
Parts Used:
WR29X10085
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
piece broke off on stripper causing ice to jam
tab on right top, flat insert on left. Pull up, toward you and to the right. It pops off. No tools needed.
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Clifton, VA
Parts Used:
WR32X26198
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken Drawer
All I had to do was slide it in. But that's not what made me so thrilled with your site. What won my devotion was your site's ease of use (I couldn't find what I was looking for on GE's site) and the promptness of delivery. I will certainly use you again and recommend your services to my friends!
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from Lincoln, CA
Parts Used:
WR01X37886
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
light burned out
unscrewed lamp and replaced it with new one!
10 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sharon from PEORIA, AZ
Parts Used:
WR12X10625
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
broken plastic freezer shelf front.
Emptyed shelf of food. Aligned new plastic front piece. Pressed front. Went right into place.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
clyde from RIALTO, CA
Parts Used:
WR60X24484, WR60X10209
Difficulty Level:
Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Lawerence, MI
Parts Used:
WR17X11505
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice would fall after removing glass.
I took the ice drawer out and turned it upside down. Then removed two philips screws holding the drawer front on. Then with a small straight edge screwdriver pry out the sides to release the locking tabs and remove the auger and crusher assembly. Then on the end of the auger remove the e-clip, slide the auger out and remove the broken part of the crusher dispenser and replace with new. Easier than it sounds. Parts Select was great to deal with. Had my parts in two days.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Centennial, AL
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light switch broke when I dropped a jar of jam on it.
The three bulbs would then remain on, so I loosened them to keep them off. I didn't know that the cooling system also would stop when the door was open, so for two days only the side freezer was operational. When I discovered that, I hot glued the switch button off, while I searched for a replacement part. The replacement part was an exact duplicate. A simple prying out of the old switch - using a screwdriver, and the reconnection of the two wires connectors to the new part, and clicking back in place ... done. Seriously, it took two minutes.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Austin from New Portland, ME
Parts Used:
WR01X37886
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
ice door light bulbs burned out
found the correct bulbs, the hardest part.
un screwed old bulb.
Screwed in new bulb.
Waa La,
There was light.
7 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Sugar Hill, GA
Parts Used:
WR12X10625
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
broken handle
Handle just snaps on.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from Miami, FL
Parts Used:
WR17X11459
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Broken cup drive
I disassymbled the cover bucket bottom from the bucket ice dispenser then found that the auger helix dispenser had broke thru the bucket. It seems the auger nut got cross threaded, this provided a problem to remove the auger. the only way to remove because the nut was wedged was to cut thru the bucket to the auger. The easy part was replacing the cup drive which was the problem along with the auger nut.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PJE25PGTEFSV
91 - 105 of 679