Customer:
Stephanie from DENVER, CO
Parts Used:
7C7
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
drum light burned out
removed the bulb from the package unscrewed the old bulb & screwed in the new bulb.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carl from SAN MARCOS, TX
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker Leaking
Researched on internet/you tube; ordered part, and did the repair. Easy to do and saved the cost of a service call.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jimmie from Surprise, AZ
Parts Used:
7C7
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Bulb burned out.
Screwed new bulb in socket
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ruben from Sylmar, CA
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Wrench (Adjustable)
Leaking water
Be careful when ordering the part. Make sure you need a Double or Single Outlet Water Valve. They look almost the same in the catalog.
Unplug the power cord and turn off the stopcock water supply valve. Unplug the 2 electrical jacks and pull-out the water hose from the compression type fitting. Use a philips screwdriverdriver to remove the bad part. Install the new part in the reverse steps.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christine from Delray Beach, FL
Parts Used:
WR17X10542
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
drawer facing cracked
ordered drawer face - perfect part- snapped right in. done. order came within 10 days.
will order again if needed.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from BRICK, NJ
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
My ice container and Ice chute were freezing up and getting blocked, and my filtered water line was also freezing
I just followed the instructions on the video and it was exactly as they said......no surprises.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Catherine from SEATTLE, WA
Parts Used:
40A15
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.

No tools needed, the cap is just held in place with pressure from the wire.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rudy from CITRUS SPGS, FL
Parts Used:
WR17X11653
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Had a drip which filled up the tray and leaked on the floor from water dispenser
There are Great videos on YouTube!!! Turned off power,Removed trim ring, Pushed a philips head screwdriver in one of the holes underneath the electrical panel with the selector push buttons. This releases the electrical panel. There are Three wire sets with plugs. I removed the plugs and took the electrical panel out. Removed four Phillips head screws and pulled out the big paddle switch. This then exposes the flapper. Replaced flapper with new one and reassembled everything. When I had everything apart, I cleaned with window cleaner. It was pretty moldy from the water leaking. Turned power back on and tested everything to make sure I didn't mess anything up. Works great
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from Poquoson, VA
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
My icemaker was leaking down the back wall of the freezer (side-by-side unit) building a huge ice flow that grew into the path of the circulation fan.
After turning the water off, I removed the two screws holding the cover on the lower back of the freezer. I disconnected the copper water supply line from the valve. I then removed the screw holding the valve in place and removed it from the freezer. I removed the two wires from the valve and placed them on the new valve (after inserting the clip inserts to match the new size tabs).I pulled the two plastic water lines out of the valve and inserted them into the new valve. I put the new valve in place and replaced the screw. Total time less than 15 minutes. Much easier to fix, than to identify the problem. The collective wisdom of the internet strikes again! Thanks to all.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
joselito from riverview, FL
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice Building Up In The Ice Dispenser Chute
Under the control panel there are three small holes. Insert ballpen or small flat screw driver on both outer holes to push a tab lock that holds the control panel in place. Then pull out control panel and three set of wires will be exposed and disconnect wire connectors (connectors have different sizes so you wont get confused in reconnecting). Unscrew four screws on each corner that holds the ice dispenser assembly (a part where you push your glass against to dispense ice or water. The flapper is exposed and easy to replace.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Chapel Hill, NC
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Leaking valve
The valve was leaking from the core and not the in/out tubes. The valve is easy to get to and very easy to replace. When replacing the water in/outs you cut them off the old valve and then slip them on the new valve. 5 to 10 minute job.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GARY from LIVONIA, MI
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice Maker Clogging up from frost build-up
Turn off power
Remove operator faceplate by pullling out on outer lower corners
Disconnect wire connectors from circuit board
Remove four screws from dispenser and pull out dispenser assy
Replcae Door ASsembly
Put everything back in place
Power up
Job Done
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chester from Chambersburg, PA
Parts Used:
WR57X10051
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench (Adjustable)
Valve leaked water and needed to be replaced
First I removed the incoming water line from the valve. I then removed the screw that hold the valve in place. Then I pulled the element out about 3 inches and disconnected the two connector wires. Next I cut the plastic hoses from the old valve.
To install the new valve, I inserted the two plastic hoses into the new valve. (hoses are different diameters so it is next to impossible to insert them incorrectly.) I replaced the electrical connectors (This was the only glitch since the one connector on the refrigerator is larger then the pins on the new valve, A little electrical tape held the connector in place.) I then tightened the screw that holds the valve on the refirgerator and reconnected the household water to line to the valve.
The entire job took less time then it has taken me to type the procedure.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ken from Wesley Chapel, FL
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
froze in freezer
unclipped and replace with new part.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Cun City Center, FL
Parts Used:
WR17X3909
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The shield light had burned the shield
I hung the new shield on the two inside pegs that were already there.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TPX24BRBAWW