- Charles from Keller, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Brandywine, MD
- Parts Used:
- WR57X10051
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
no Ice
Turned off The water supply. Removed the back panel corner(nut driver). Removed valve (nut driver) and water supply inlet line. Cut the old outlet lines at the valve (new lines are push in) disconnected electrical lines, Reinstalled inlet line and electrical lines. Reinstalled valve and back panel. Turned on the water. Ice maker filled with water and a short time later I had ice. Easy job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Manorville, NY
- Parts Used:
- WR13X10020
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
door wouldn't close
First I propped up the door. Then I removed the 2 screws that hold the hinge on. AT this point you do need someone else because the door swings loose. I attached the new bracket and lowered the door. It went verey smooth. I ordered the new bracket after reading the installation stories from others who just repaced the plastic pieces. Its worth the extra money to just put on a new bracket
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Seaford, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer stayed cold but Fridge got warm every 3 weeks
Unplug the fridge, then:
1) Remove food and shelves from freezer
2) Remove rear panel from inside freezer (panel that covers the evaporator coils)
3)Stare at all the ice covering the coils for 10 seconds!
4) Plug the drain hole in the bottom left side of the freezer (cork or plug made from rolled up paper towel), and place a big towel in the bottom of the freezer compartment to absorb the melting ice
5) Plug in a table fan and leave it blowing into the freezer compartment, at the iced-over coils. Come back in 30 minutes.
6) Ice should be all melted. Place the wet towel in a bucket.
7) Remove the little clip attached to the green wire from the top of the panel., and then remove the two top screws on either side of the panel covering the coils. Take out the panel.
8) Removed the two screws that hold the heater element in place at the bottom of the coils. Pull the element out about 3 inches and disconnected the two wires.
9) Connect the wires to the new heater element, and screw it back into place. Put panel back, shelves in, turn fridge on. Fixed
I ordered the defrost heater and replaced that, also ordered the defrost thermostat but the old one looked fine so I did not replace that. Fridge and freezer have been working great, no more icing problems.
Thank You PartSelect!
1) Remove food and shelves from freezer
2) Remove rear panel from inside freezer (panel that covers the evaporator coils)
3)Stare at all the ice covering the coils for 10 seconds!
4) Plug the drain hole in the bottom left side of the freezer (cork or plug made from rolled up paper towel), and place a big towel in the bottom of the freezer compartment to absorb the melting ice
5) Plug in a table fan and leave it blowing into the freezer compartment, at the iced-over coils. Come back in 30 minutes.
6) Ice should be all melted. Place the wet towel in a bucket.
7) Remove the little clip attached to the green wire from the top of the panel., and then remove the two top screws on either side of the panel covering the coils. Take out the panel.
8) Removed the two screws that hold the heater element in place at the bottom of the coils. Pull the element out about 3 inches and disconnected the two wires.
9) Connect the wires to the new heater element, and screw it back into place. Put panel back, shelves in, turn fridge on. Fixed
I ordered the defrost heater and replaced that, also ordered the defrost thermostat but the old one looked fine so I did not replace that. Fridge and freezer have been working great, no more icing problems.
Thank You PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Phillip from Springfield, VA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Ice chute frosted up
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chip from Mandeville, LA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Jacksonville, FL
- Parts Used:
- WR17X2059
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
crushed ice feature inoperative, broken pieces in water dispensed.
Found broken pieces of deflector in delivered ice. Removed dispenser, carefully disassembled it, marking fasteners, sprimgs, and levers. Local repaimen say no replacement part available, must replace entire ice maker @ $350. Found exact part in your online reference, ordered at price of $3.76, part arrived two days later--perfect fit, exactly same as original. Reassembled, and it works exactly like new. Family very happy. Good job!!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from Elkridge, MD
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The Ice Flapper warped and clogged up the Ice Shoot
I bought a Flapper replacement part from Parts Select. I installed it following their very complete on-line video directions. Their complete and easy to follow directions made my job very easy, and the work was completed without any problems and just as good as if it were done by a professional repair person. I am proud of my work, it couldn't have been done without their video insructions. Also I got delivery of the part within two days of my order. I will alway look for Parts Select any time I need an applicance repaired. Thanks to Parts Select!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dean from Folsom, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- samuel from FAIRVIEW PARK, OH
- Parts Used:
- WR72X10009, WR72X10007
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
drawer rails were broken
. i found this site that has a diagram of the refrigerator was able to get the right parts. it was just a matter of removeing two screws and installing the new rails. very easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Los Altos, CA
- Parts Used:
- WR02X10140
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Hinge Cam Riser broke - door wouldn't self-close
I removed all of the items in the refrigerator door. I then removed the top hinge cover with a Philips screwdriver, and removed the two machine screws holding the top hinge using a socket wrench. This allowed me to lift the door off the bottom hinge pins and set the door on its side. I removed the two screws holding on the broken bottom hinge cam riser block and replace it with the new one. After tighening it back with a socket wrench, I tried to put the door back in place. I asked my wife to hold the door steady while I lay on the floor to guide the door downward over the bottom hinge pin. I then replaced the top hinge screws and checked the door. It still didn't close on its own! I realized I had to loosen the top hinge screws and adjust the door so that it stands more vertically (evening the gap with the freezer door). With this adjustment, the door closes fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Sweet Home, OR
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
evaporator coils iced up causing no cooling in freezer or fridge.
First I disconnected the Power from the unit. Pulled out the freezer drawers and the ice machine used a 1/4 inch nut driver and removed the sheet metal from the back of the freezer exposing the evaporator coils. I defrosted the coils. Then I removed the two screws holding the defrost heater braket assembly and removed the two electrical connections from it. I then installed the new heater put everything back together(reverse of installation)and it works like a brand new fridge and freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from San Marcos, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Elk Grove, CA
- Parts Used:
- WR13X10020
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
cam closing washer broken
I propped up the door with 2x4 and shims to be level with the freezer door. Then removed the 2 screws holding the hinge to the main unit. Then removed the 2 screws holding the cam washer to the door.
Replacement was the reverse of disassembly. Be sure to tighten screws almost tight until both pieces are located correctly then fully tighten. Lift up refrigerator door slightly to remove shims and wood block.
I did the replacement myself but was nervous that the door would fall off the block and shims. I recommend having another person hold the door closed during the process.
Replacement was the reverse of disassembly. Be sure to tighten screws almost tight until both pieces are located correctly then fully tighten. Lift up refrigerator door slightly to remove shims and wood block.
I did the replacement myself but was nervous that the door would fall off the block and shims. I recommend having another person hold the door closed during the process.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Ashford, CT
- Parts Used:
- WR57X10051
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Cold water dispencing was becoming slower and volume of ice was becoming less.
Shut water supply off, removed power plug from wall and removed electrical connector from valve. Unscrewed two plastic nuts which retained lines to old valve. Remove old valve and reinstalled new valve with one screw. Removed inserts from end of lines. (These inserts keep lines from deforming.). Trimmed and chamfered ends of lines reinstalled inserts and installed lines to new valve. Turned on watter, checked for leaks turned power on inserted glass for water received good flow. Ice maker did not receive water. Due to low flow of water to ice tray because of low flow with old valve, ice built up in flexable water delivery tube that goes from back of refrigator to ice tray. Removed tube ran under warm water removed ice blockage reinstall tube all working excelent. This iceing problem took about anouther 15 to 25 min to correct.
Was this instruction helpful to you?
Thank you for voting!