Aliki from Miami, FL
Parts Used:
WP628356
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
6 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Winston A from Brooklyn, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
riley from CAVE CREEK, AZ
Parts Used:
WP65889-4
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Summerville, SC
Parts Used:
W10190935
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The icemaker quit making ice.
With instructions from PartSelect.com this was an easy fix. I tested the motor's electric as suggested and was satisfied that the Motor Module (WPL W10190935) would correct the problem. UNPLUG THE REFRIGERATOR! I popped the outside plastic cover off to expose the unit. (1) remove the wire unit that runs the length of the cube maker (2) remove the 3 screws that secure the motor unit and carefully remove it (3) carefully line up the new unit, slide in place and replace the 3 screws (4) install the wire that was removed in step(1). Connect electric to the refrigerator and wait about 2 hours for your first ice cubes. PartSelect.com is the ONLY supplier that you will ever need! Great instructions and trouble shooting suggestions. Shipping is incredibly fasssst! Customer contact is awesome. Don't hesitate to buy from them! Saved me about $200.! Good luck....Tom in SC
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
frank from NORTHRIDGE, CA
Parts Used:
WPD7813010
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice maker not producing ice
The parts were very easy to replace, however I am still without ice and cannot figure out why. I have ohm tested the contol unit and everything works fine, I am able to jump it and turn on the motor and water fill valve. Any suggestions?...
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from VESTAL, NY
Parts Used:
W11176463
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
Old fill tube was blocked
Cut old fill tube into pieces, removed and replaced with new tube. Extremely easy.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Holden, MA
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Divider front of fridge hot to touch Condenser fan not working
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Moore, OK
Parts Used:
D7824706Q
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
ice maker was over filling and causing water to flow into ice dispenser and freezing it al together
First turned off the water and unplugged the refrigerator and then removed the old ice maker by first removing the side cover plate and then next removed the ice level detector. Remove the screws that hold the ice maker in place and rotating it somewhat soas to gain access to the wires and then unplugged them. Next I had to modify the way the water comes into the new icemaker by adapting a CPVC street ell to fit into the hole on the side and then hook up the water supply. Installation is just the reverse of removal.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alfred from Tacoma, WA
Parts Used:
D7714408, 8009
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Light socket was burned for some reason, may have been wrong bulb previously.
I removed the cover over the light and disconnected the wires and replaced the socket.
6 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from San Juan Capistrano, CA
Parts Used:
WP12550109Q
Difficulty Level:
Very Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
old seal was shot
New seal arrived basically folded in half for shipping. Was advised to use hair dryer and/or hot water to restore original shape. Neither worked. I installed it anyway and am waiting (3 days so far) for it to seal (so far, no luck). I'll give it another day or 2, re-install the old one and write off the $75
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Sunnyvale, CA
Parts Used:
WP98165, D7824706Q
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
leaky ice maker - non-stick coating had failed
replaced the entire ice make - 3 screws and a squeeze -off connector and it's out. Reverse to re-install... except that the fill tube had iced up. To thaw the fill tube: unload freezer section (leave food in fridge, but keep door closed), remove ice maker. Boil water, dip drill bit (dull end) into hot water, swirl around, insert (dull end) into to fill tube. Depending on how hot you got it, maybe a tablespoon of ice will melt. Repeat many times - fill tube is about 14" long! Do not use anything sharp - you will nick the tube and ice will form causing you to repeat this procedure. Do not try to break the ice - let the heat work. It took me about 30 minutes to thaw the whole thing - it made a nive gasping noise when the final plug opened up. Re-install ice maker.
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
richard from colorado springs, CO
Parts Used:
D7824706Q
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara H. from South Hill, VA
Parts Used:
WP65889-4
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
anthony from HAVELOCK, NC
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
changed the light bulb still would not work so I figured it was the switch sure enough.
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tonya from Grand Prairie, TX
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!