- Customer:
- Denise from NORTH BEACH, MD
- Parts Used:
- 6930W1A003X
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Thermostat needed to be replaced
We had made this determination with the help of a repairman on the phone. I ordered the part and waited for it. It was stuck in West Virginia. After several days after it was expected a repairman fixed my range to the tune of $168. It should have cost $30 (the cost of the part and shipping).
Unfortunately I probably won't order from PartSelect again.
Unfortunately I probably won't order from PartSelect again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Benjamin from Anchorage, AK
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replacement of Magnetron
I UNPLUGGED the microwave and removed the cover, using a phillips and a Torx screwdriver for the machine screws. I set these screws aside, so as not to confuse them with the later encountered screws. I photographed the magnetron to assure proper placement of the 6 phillips machine screws involved in reassembly (marking the the locations on the old magnetron would do as well. I marked the old magnetron "old", to avoid later confusion. I removed the two screws holding the shields to the magnetron. I removed 3 of the 4 screws holding the magnetron to the microwave, leaving one of the top screws. I held the magnetron securely and removed the last screw, pulling out a the part of the magnetron that penetrated the microwave. I installed the new magnetron in reverse order. One problem I encountered was locating one of the six screws, which had been pulled into the old magnetron by magnetism.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Samuel from Daleville, VA
- Parts Used:
- 3501W1A019D
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Microwave would not heat food, but everything else worked.
Problem was a faulty door latch switch. I easily accessed the switch by removing the control panel, total of 4 screws. After that, just disconnected the three switch door latch assembly and connected the new one. Took about half an hour and was very easy. Unit works perfectly now.
Was this instruction helpful to you?
Thank you for voting!
Had to lift on the door for the microwave to run, suspected the door switches.
Ordered the switches from Partselect, arrive in two days. Had trouble removing the plastic connectors from the old switch terminals, one of the plastic protectors broke, but was able to reuse it. It took a little figuring out how to remove the existing switches. Must push in a tab and rotate the switch on a little pin, then remove. Must be careful not to break the plastic tabs holding the switches in place. Replaced all (3) switches at the same time. All in all it was pretty easy.
Was this instruction helpful to you?
Thank you for voting!