36363693303 Kenmore Microwave - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Ronald from PONCA CITY, OK
- Parts Used:
- WB27X10928
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Frost build up on bottom to ice bin and delivery chute in door creating ice blockage
Remove the ice bin.
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of the freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of the freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kathy from SAN DIEGO, CA
- Parts Used:
- WB10X10021
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Door latch broken
I read your instructions sent with the new latch. Looked at a couple videos online and it was VERY easy to change the part. Thanks so much?
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Galen from SAN SABA, TX
- Parts Used:
- WB10X10021
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Broken microwave door latch.
Watched Utube instructions on how to do it to it and just did it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from RIVER RIDGE, LA
- Parts Used:
- WB10X10021
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Door Latch Assembly Broke
This is a simple task. Removed the choke cover using a putty knife or small flat screw driver. Putty knife works best. Slide putty knife under the plastic choke cover to lift up over clips all around the door. There are 3 on top and Bottom and 2 on each side. Be very careful or you will break the catch clips that hold the choke cover in place. Lift the door latch up all the way and push towards the outside of the door, then pull the top or bottom out then the rest of it. Unhook the spring end from the door. Attach the new spring to the hook on the door and then to the door latch. Extend it up all the way so the 2 hook parts of the door latch can go back into their slots. Unlike some others said, the microwave door does not need to be removed. If you have someone to hold the door still, that's good enough. I did it by myself with no problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sherman from Memphis, TN
- Parts Used:
- WB10X10021
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
The Door Latch on the Avantium Microwave Oven
I removed the door, by taking off the grill at the top. Then, take the puddy knife and screw driver and pry the facing off of the door. Please remember to be very careful because this is a sensitive piece. This is the most difficult part. It is a piece of cake after this. This should take about 15 minutes from beginning to end.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from Bend, OR
- Parts Used:
- WB10X10021
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Door handle latch
We opened the microwave door and essentially with a straight screwdriver worked to "pop" the plastic frame off of the door. We tried to be less aggressive in our efforts and this paid off since we didn't break anything! The area we needed to work on was now exposed to put the new latch in. It took 2 hands rather than 3 to get the new latch attached and then wah-lah, It was done! Microwave works perfectly now. Great alternative to buying a new microwave!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gloria from ROSSFORD, OH
- Parts Used:
- WB49X10129
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Broken Glass Cooking Tray
Placed the new tray into the oven.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lorraine from MIDDLETOWN, NY
- Parts Used:
- WB49X10129
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Lawn mower would not start
removed cover over motor blew it out of leaves and dust. Removes 4 screws and removed piece ordered. The coil was rusted and not connecting. Changed oiece its working again
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pearlie from Beulaville, NC
- Parts Used:
- WB27X10928
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Timer, light and control pad worked. Turn table and heat did not work. Oven would not start up.
I first read where someone had the same problem. Their solution was a burned-out fuse. I ordered a new fuse...installed it and that did not solve my problem. I revisted PartSelect and read how Marla (from Arlington, TX)solved her problem. I purchased a secondary switch and when it arrived, I made a copy of Marla's instructions and followed them to the letter. I installed the new secondary switch into the secondary space, put everything back together and the oven STILL DID NOT WORK. I had to take the latching panel apart again and test each switch to see if there was another bad one. I found that the third switch was burned out. So I took the new switch out of the second slot and installed it into the third slot. I tested the switches before reinstalling the latching panel. This time everything worked. So I put everything back together, reinstalled the microwave on the wall, tested it again, and everything worked perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wilson from Pembroke Pines, FL
- Parts Used:
- WB10X10021
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
broken latch
We used the scresdriver(flat) to remove the frame inside the door, the remove several screws retaining the inner part of the door thenremoved the broken piece. We replaced the latch with the spring With a little patience, everything went fine. I broke one of the small tab, no big deal.
thanks, you saved me a lot of money/.
thanks, you saved me a lot of money/.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rex from ROSEVILLE, CA
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Microwave wouldn’t heat
I want to preface this review by stating that I do some DIY from YouTube, but have no experience in electronic repair. The microwave is over the stove with the extendavent. First I unplugged the microwave, removed the vent and started to unscrew the microwave from the mount. I used a power drill to speed things up. I was able to remove the microwave on my own. I unscrewed the lid on the microwave and took the lid off and there is the magnetron. I opened up needle nose pliers to have each end touch the terminals of the capacitor (holds the power, Dangerous). I made sure to keep my hands on the rubber handles and avoid touching the metal part of the pliers. I used the pliers to remove the plug of the capacitor to the magnetron as well. The magnetron has 4 screws (2 top, 2 bottom). There is a magnet that can hold the screws to keep from falling but I’d still recommend a screwdriver with a magnet on the end. The magnetron has another set of wires connected by a metal bracket like a holder, not really connecting any wiring to the magnetron itself. I had to unscrew 1 screw to removed that. Adding everything back on was easy, same steps back. I plugged in the microwave and tested a cup of water before I mounted it back above the stove. Voila! I did need my wife’s help to hold the microwave on the hinge while screwing into the mount. It doesn’t take a lot of muscle for the help. $85 for the part and ~40 mins to fix a $400 microwave!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kip from POWELL, OH
- Parts Used:
- WB27X10928
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Not heat
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stacie from Granbury, TX
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Microwave would not heat. Convection still worked.
I verified I had 120 volts going into transformer when the microwave was supposed to be running. The capacitor and HV diode both tested good. Be sure to discharge the capacitor before working in this area. This isolated trouble to either the transformer or magnetron. The windings of the transformer measured good. So ordered a magnetron. It was very easy to swap. There were 4 screws and one connector. This fixed our microwave.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Judith A from LAKEWOOD, CO
- Parts Used:
- WB36X10163
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light bulb went out
Opened the light cover. Removed the old light bulb using a light tug on the old bulb, lined up the new bulb and pushed gently into the socket.
Turned the power back on and the microwave is good to go.
Turned the power back on and the microwave is good to go.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Loretta from PRT JEFFERSON, NY
- Parts Used:
- WB10X10021
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
door latch broken
removed broken latch connected to existing spring done in less than two minutes works better than new
Was this instruction helpful to you?
Thank you for voting!