JES1351WB03 General Electric Microwave - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Stacie from Granbury, TX
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Microwave would not heat. Convection still worked.
I verified I had 120 volts going into transformer when the microwave was supposed to be running. The capacitor and HV diode both tested good. Be sure to discharge the capacitor before working in this area. This isolated trouble to either the transformer or magnetron. The windings of the transformer measured good. So ordered a magnetron. It was very easy to swap. There were 4 screws and one connector. This fixed our microwave.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pearlie from Beulaville, NC
- Parts Used:
- WB27X10928
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Timer, light and control pad worked. Turn table and heat did not work. Oven would not start up.
I first read where someone had the same problem. Their solution was a burned-out fuse. I ordered a new fuse...installed it and that did not solve my problem. I revisted PartSelect and read how Marla (from Arlington, TX)solved her problem. I purchased a secondary switch and when it arrived, I made a copy of Marla's instructions and followed them to the letter. I installed the new secondary switch into the secondary space, put everything back together and the oven STILL DID NOT WORK. I had to take the latching panel apart again and test each switch to see if there was another bad one. I found that the third switch was burned out. So I took the new switch out of the second slot and installed it into the third slot. I tested the switches before reinstalling the latching panel. This time everything worked. So I put everything back together, reinstalled the microwave on the wall, tested it again, and everything worked perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from FULSHEAR, TX
- Parts Used:
- WB24X10047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
M/W would not start. control panel OK
unplugged power
removed main black cover.
located part WB24X10047 and replaced
removed main black cover.
located part WB24X10047 and replaced
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rex from ROSEVILLE, CA
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Microwave wouldn’t heat
I want to preface this review by stating that I do some DIY from YouTube, but have no experience in electronic repair. The microwave is over the stove with the extendavent. First I unplugged the microwave, removed the vent and started to unscrew the microwave from the mount. I used a power drill to speed things up. I was able to remove the microwave on my own. I unscrewed the lid on the microwave and took the lid off and there is the magnetron. I opened up needle nose pliers to have each end touch the terminals of the capacitor (holds the power, Dangerous). I made sure to keep my hands on the rubber handles and avoid touching the metal part of the pliers. I used the pliers to remove the plug of the capacitor to the magnetron as well. The magnetron has 4 screws (2 top, 2 bottom). There is a magnet that can hold the screws to keep from falling but I’d still recommend a screwdriver with a magnet on the end. The magnetron has another set of wires connected by a metal bracket like a holder, not really connecting any wiring to the magnetron itself. I had to unscrew 1 screw to removed that. Adding everything back on was easy, same steps back. I plugged in the microwave and tested a cup of water before I mounted it back above the stove. Voila! I did need my wife’s help to hold the microwave on the hinge while screwing into the mount. It doesn’t take a lot of muscle for the help. $85 for the part and ~40 mins to fix a $400 microwave!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kip from POWELL, OH
- Parts Used:
- WB27X10928
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Not heat
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Suzanne from POWELL, OH
- Parts Used:
- WB24X10047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
Microwave would not heat up
Part just snapped into place and wires were reattached.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gilbert from TOMS RIVER, NJ
- Parts Used:
- WB24X10047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Door Switch went bad, Internal Fan would run every time you open the door
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- johnny from port orange, FL
- Parts Used:
- WB24X10047
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
no power in microwave in turn table wouldn't turn light would work act like door was open
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from Wesley Chapel, FL
- Parts Used:
- WB24X10047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Turntable Stopped Working/Display Timer Would Countdown But Not Heat
With this model, you must remove the outer covering. Don't try to access the display unit from the front like I've seen in some other GE microwave videos. After removing the outer covering, the switches are easy to replace. They are very visible and easy to get to without taking any other parts off. You will see the door switches just behind the display board. Remove the switch and then remove the connecting wires to ensure you don't inadvertently brake a wire. You will need a tamper resistant star bit to remove 3 or 4 screws from the back panel. All other screws are philips head. I went ahead and replaced both switches (yes...there are two of them) and works like a charm. I saved an $800 microwave for less than $60 and know what to do if it happens again. Appears to be a common problem on this model. Thanks for others making a post...It saved me time and money reading others remarks. Good luck!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edwin from New York, NY
- Parts Used:
- WB27X10928
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
No heat
Replace the fuses
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Nelia from Streamwood, IL
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
no heat
unplug the unit then pull down , lot of screws are on top. open the cover . you could see the parts that need to replace on the right hand side (heavy side). disconnect wires then test the parts that need to replace by a tester to make sure that it's really broke .then unscrew part and replace .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Benjamin from Anchorage, AK
- Parts Used:
- 6324W1A001L
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replacement of Magnetron
I UNPLUGGED the microwave and removed the cover, using a phillips and a Torx screwdriver for the machine screws. I set these screws aside, so as not to confuse them with the later encountered screws. I photographed the magnetron to assure proper placement of the 6 phillips machine screws involved in reassembly (marking the the locations on the old magnetron would do as well. I marked the old magnetron "old", to avoid later confusion. I removed the two screws holding the shields to the magnetron. I removed 3 of the 4 screws holding the magnetron to the microwave, leaving one of the top screws. I held the magnetron securely and removed the last screw, pulling out a the part of the magnetron that penetrated the microwave. I installed the new magnetron in reverse order. One problem I encountered was locating one of the six screws, which had been pulled into the old magnetron by magnetism.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mack from Jacksonville, FL
- Parts Used:
- WB27X10928
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
No heat.
Replaced the fuse. Result; did not fix the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sam from Chandler, AZ
- Parts Used:
- WB24X10047
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
When trying to run, intermittently, the light would come on but the tray wouldn't rotate or cook. When the door was open, the tray would intermittently rotate.
I pulled out the unit and found 2 interlock switches that are depressed when the door closes. After cycling the door open/closed I found that one of the switches occasionally would stay depressed. The repair was easy (after I took off the panels so I could get to the switch) I simply removed 2 screws that attached the interlock switch assemblies to the main unit. Then I popped out the defective switch and popped in the new one. This did indeed fix my problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- J Roberto from Houston, TX
- Parts Used:
- WB26X10056
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The tray was not rotating.
Follow the instructions I got from the website and replacing the motor was very easy to do. Thank you.
Was this instruction helpful to you?
Thank you for voting!